Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2024-010842
Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 6/5/2024 Tanknology WO#NW1-2368535 Test Purpose COMPLIANCE Customer PO# Customer Location U.S. FOODS 9399 HIGGINS ROAD SUITE 500 ROSEMONT, IL 60018 U. S. FOODS 4H 835 W SAN JOSE ST OGDEN, UT 84401 Attn: JILL TUBBS Attn: (847) 720-1712 (801) 917-3374 Test / Inspection Description Item Tested Date Tested Result Precision Tank Tightness Tank TNK1 Low Sulfur Diesel 6/5/2024 Pass Precision Line Tightness (.1 GPH) Tank TNK1 Line 1 Low Sulfur Diesel 6/5/2024 Pass Precision Line Tightness (.1 GPH) Satellite Line 1 6/5/2024 Tested w/ Primary Precision Line Tightness (.1 GPH) Satellite Line 2 6/5/2024 Tested w/ Primary Precision Line Tightness (.1 GPH) Satellite Line 3 6/5/2024 Tested w/ Primary Precision Line Tightness (.1 GPH) Satellite Line 4 6/5/2024 Tested w/ Primary PEI RP 1200 Leak Detector See test report for details 6/5/2024 Pass Impact Valve Inspection See test report for details 6/5/2024 Pass RP 1200 ATG See test report for details 6/5/2024 Pass RP 1200 Sensors See test report for details 6/5/2024 Pass Sump Inspection See test report for details 6/5/2024 Pass Tanknology Representative: David Edens Technician: David Mathie Telephone: ()Technician Certification: (See forms) VacuTect Tank Tightness Test page 1 of 1 Work Order:2368535 Date:6/5/2024 Site Name/ID:U. S. FOODS 4H 4H Address:835 W SAN JOSE ST City:OGDEN State:UT Zip:84401 Tank Information Customer Tank ID Regulatory Tank ID Product Category Product Name Gallons Capacity Tank Type Tank Walls Compartmentalized Siphon Tank Vents included with test Test Start Time Test End Time Water ingress (Y/N) Bubble ingress (Y/N) Ullage ingress (Y/N) Test Result (P/F/I) TNK1 Low Sulfur Diesel TNK1 Diesel Low Sulfur Diesel 19951 Fiberglass Doublewall (factory) No No with this tank 11:24:00 12:41:00 No No No Pass Yes - Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281. No - diagnostic only Technician Comments : UT151 Technician Name David Mathie Certification #41448 exp: 10/20/2025 Technician Signature Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin,TX. All rights reserved. tanknology.com Product Line Tightness Test Page 1 of 1 Work Order: 2368535 Date: 6/5/2024 Site Name/ID: U. S. FOODS 4H / 4H Address: 835 W SAN JOSE ST City: OGDEN State: UT Zip: 84401 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 TNK1 Low Sulfur Diesel Pressure 60 11:36 12:36 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Product Line Tightness Test Satellite Line Tightness Test Page 1 of 1 Work Order: 2368535 Date: 6/5/2024 Site Name/ID: U. S. FOODS 4H / 4H Address: 835 W SAN JOSE ST City: OGDEN State: UT Zip: 84401 Satellite Line # Fueling From - To Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Sat # 1 1 - 1S Low Sulfur Diesel Pressure Included with primary line test Sat # 2 2 - 2S Low Sulfur Diesel Pressure Included with primary line test Sat # 3 3 - 3S Low Sulfur Diesel Pressure Included with primary line test Sat # 4 4 - 4S Low Sulfur Diesel Pressure Included with primary line test Sat # Sat # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com U. S. FOODS 4H 835 W SAN JOSE ST OGDEN UT 84401 4H Tanknology, Inc. U.S. FOODS 9399 HIGGINS ROAD SUITE 500 ROSEMONT IL 60018 847-720-1712 06/05/2024 Low Sulfur Diesel Veeder Root FX1DV 40 20 250 2 10 3 UT151 David Mathie NW1-2368535 TTNK1:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2368535 Date:6/5/2024 Site Name/ID:U. S. FOODS 4H Address:835 W SAN JOSE ST City:OGDEN State:UT Zip:84401 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1S/ 40 Pass Fail Not Tested 3/4 40 Pass Fail Not Tested 3S/ 40 Pass Fail Not Tested 5/2S 40 Pass Fail Not Tested 6/4S 40 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com U. S. FOODS 4H U.S. FOODS 835 W SAN JOSE ST OGDEN UT 84401 4H Tanknology, Inc. 9399 HIGGINS ROAD SUITE 500 ROSEMONT IL 60018 847-720-1712 800-964-1250 06/05/2024 1 DSL VR350 19951 119.5 UT151 David Mathie 835 W SAN JOSE ST U. S. FOODS 4H 835 W SAN JOSE ST , OGDEN, UT 84401 4H Tanknology, Inc. U.S. FOODS 9399 HIGGINS ROAD SUITE 500 ROSEMONT, IL 60018 847-720-1712 06/05/2024 ANNULAR WET STP UDC UDC UDC UDC UDC DSL DSL 1 S 3 S 1/2 3/4 2S/5 UT151 David Mathie 835 W SAN JOSE ST U. S. FOODS 4H 835 W SAN JOSE ST , OGDEN, UT 84401 4H Tanknology, Inc. U.S. FOODS 9399 HIGGINS ROAD SUITE 500 ROSEMONT, IL 60018 847-720-1712 06/05/2024 UDC 4S/6 UT151 David Mathie ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 6/5/2024 UST Facility Person Conducting Test Facility Name U. S. FOODS 4H Facility ID # OGDEN Tester's Name DMATHIE Physical Address 835 W SAN JOSE ST Company Tanknology Inc. City OGDEN County WEBER State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner U.S. FOODS Tester's Signature Date 6/5/2024 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2024 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:TNK1 Low Sulfur Diesel - 1 N Y Y Y N Pass Comments: WO: 2368535 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2368535 Site ID / Name:4H / U. S. FOODS 4H Address:835 W SAN JOSE ST City:OGDEN State:UT Zip:84401 W.O.# NW1-2368535 OVF W.O.# NW1-2368535 +AAE- I10100 JUN 5, 2024 12:56 PM U.S. FOOD SERVICE 835 SAN JOSE OGDEN, UTAH 84401 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I90200 JUN 5, 2024 12:56 PM SOFTWARE REVISION LEVEL VERSION 128.03 SOFTWARE+ACM- 346128-100-D CREATED - 08.06.06.17.51 S-MODULE+ACM- 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD +AAMAAQ- I20100 JUN 5, 2024 12:56 PM U.S. FOOD SERVICE 835 SAN JOSE OGDEN, UTAH 84401 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 DIESEL 7413 7371 12538 48.09 0.00 72.52 +AAMAAQ- I30100 JUN 5, 2024 12:56 PM U.S. FOOD SERVICE 835 SAN JOSE OGDEN, UTAH 84401 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 ANNULAR303 SENSOR NORMAL 2 STP SUMP SENSOR NORMAL 3 S1 NO SAT SENSOR NORMAL 4 S3 SO SAT SENSOR NORMAL 5 1-2 DUAL MASTER SENSOR NORMAL 6 3-4 DUAL MASTER SENSOR NORMAL 7 5NO COMBO SENSOR NORMAL 8 6SO COMBO SENSOR NORMAL +AAMAAQ- I30200 JUN 5, 2024 12:56 PM U.S. FOOD SERVICE 835 SAN JOSE OGDEN, UTAH 84401 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ANNULAR303 JUN 5, 2024 10:40 AM LOW LIQUID ALARM MAR 14, 2024 8:43 AM LOW LIQUID ALARM MAR 14, 2024 8:42 AM LOW LIQUID ALARM 2 STP SUMP JUN 5, 2024 11:26 AM FUEL ALARM SEP 5, 2023 8:30 AM FUEL ALARM SEP 4, 2023 4:17 AM FUEL ALARM 3 S1 NO SAT JUN 5, 2024 11:33 AM FUEL ALARM JUN 6, 2023 9:19 AM FUEL ALARM JUN 6, 2023 9:19 AM SENSOR OUT ALARM 4 S3 SO SAT JUN 5, 2024 11:27 AM FUEL ALARM JUN 6, 2023 9:19 AM FUEL ALARM JUN 22, 2022 9:41 AM FUEL ALARM 5 1-2 DUAL MASTER JUN 5, 2024 11:28 AM FUEL ALARM JUN 6, 2023 9:18 AM FUEL ALARM JUN 22, 2022 9:41 AM FUEL ALARM 6 3-4 DUAL MASTER JUN 5, 2024 11:28 AM FUEL ALARM JUN 6, 2023 9:18 AM FUEL ALARM JUN 22, 2022 9:41 AM FUEL ALARM 7 5NO COMBO JUN 5, 2024 11:28 AM FUEL ALARM JUN 6, 2023 9:19 AM FUEL ALARM JUN 6, 2023 9:07 AM FUEL ALARM 8 6SO COMBO JUN 5, 2024 11:29 AM FUEL ALARM JUN 6, 2023 9:19 AM FUEL ALARM JUN 22, 2022 9:42 AM FUEL ALARM +AAMAAQ- I20600 JUN 5, 2024 12:56 PM U.S. FOOD SERVICE 835 SAN JOSE OGDEN, UTAH 84401 TANK ALARM HISTORY TANK 1 DIESEL HIGH WATER ALARM JUN 5, 2024 10:50 AM JUN 6, 2023 8:18 AM SEP 8, 2022 10:56 PM OVERFILL ALARM JUN 5, 2024 11:25 AM JUN 6, 2023 9:03 AM SEP 9, 2022 7:38 AM LOW PRODUCT ALARM JUN 5, 2024 11:26 AM JUN 5, 2024 10:46 AM APR 5, 2024 1:38 PM HIGH PRODUCT ALARM JUN 5, 2024 11:25 AM MAY 1, 2024 3:28 PM FEB 14, 2024 10:54 AM INVALID FUEL LEVEL SEP 9, 2022 6:09 AM SEP 9, 2022 6:03 AM SEP 9, 2022 5:09 AM PROBE OUT JUN 5, 2024 12:31 PM JUN 5, 2024 10:46 AM APR 5, 2024 9:06 AM HIGH WATER WARNING JUN 5, 2024 10:50 AM JUN 6, 2023 8:18 AM SEP 8, 2022 10:56 PM DELIVERY NEEDED JUN 5, 2024 11:26 AM JUN 5, 2024 10:46 AM MAY 29, 2024 6:19 PM MAX PRODUCT ALARM JUN 6, 2023 9:04 AM SEP 7, 2022 8:52 PM SEP 7, 2022 8:52 PM LOW TEMP WARNING JUN 6, 2023 10:38 AM SEP 9, 2022 4:11 AM SEP 9, 2022 2:27 AM +AAMAAQ- I20700 JUN 5, 2024 12:56 PM U.S. FOOD SERVICE 835 SAN JOSE OGDEN, UTAH 84401 TANK LEAK TEST HISTORY T 1:DIESEL LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE JUN 5, 2024 9:31 AM 33 11667 58.5 CSLD FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE JAN 28, 2024 1:18 PM 45 14553 72.9 CSLD FEB 2, 2024 8:47 PM 38 14583 73.1 CSLD MAR 29, 2024 5:49 PM 32 16201 81.2 CSLD APR 19, 2024 4:14 PM 29 13960 70.0 CSLD MAY 18, 2024 1:21 AM 31 16305 81.7 CSLD JUN 1, 2024 11:48 AM 31 11944 59.9 CSLD JUL 2, 2023 9:49 AM 42 15248 76.4 CSLD AUG 20, 2023 1:43 PM 37 15118 75.8 CSLD SEP 19, 2023 2:35 PM 35 16618 83.3 CSLD OCT 18, 2023 7:11 AM 36 13757 69.0 CSLD NOV 20, 2023 8:41 AM 35 15097 75.7 CSLD DEC 16, 2023 9:10 AM 34 14466 72.5 CSLD +AAMAAQ- IA0100 JUN 5, 2024 12:56 PM TYPE CODE LENGTH SERIAL NO. D/CODE TANK 1 DIESEL MAG D004 120.00 561520 4904 +AAMAAQ- 931 TANK 1 SETUP CONDITIONS PRODUCT: DIESEL PRODUCT CODE 1 HIGH WATER LIMIT 2.5 OVERFILL LIMIT: 18953 HIGH PRODUCT LIMIT: 17956 LOW PRODUCT: 4000 SUDDEN LOSS LIMIT: 99 LEAK LIMIT: 8 THERMAL COEFF: 0.000450 DELIVERY DELAY: 5 TANK FULL CAPACITY: 19951 0 0 0 0 3/4 HEIGHT CAPACITY: 16124 0 0 0 0 1/2 HEIGHT CAPACITY: 9935 0 0 0 0 1/4 HEIGHT CAPACITY: 3758 0 0 0 0 TANK DIAMETER: 119.50 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- I61100 JUN 5, 2024 12:57 PM LEAK TEST METHOD - - - - - - - - - - - - TEST CSLD : ALL TANK Pd +AD0- 95+ACU- CLIMATE FACTOR:MODERATE REPORT ONLY: DISABLED TST EARLY STOP:DISABLED +AAMAAQ- I70300 JUN 5, 2024 12:57 PM LIQUID TYPE SENSOR LOCATION TYPE 1 ANNULAR303 DUAL POINT HYDROSTATIC 2 STP SUMP TRI-STATE (SINGLE FLOAT) 3 S1 NO SAT TRI-STATE (SINGLE FLOAT) 4 S3 SO SAT TRI-STATE (SINGLE FLOAT) 5 1-2 DUAL MASTER TRI-STATE (SINGLE FLOAT) 6 3-4 DUAL MASTER TRI-STATE (SINGLE FLOAT) 7 5NO COMBO TRI-STATE (SINGLE FLOAT) 8 6SO COMBO TRI-STATE (SINGLE FLOAT) +AAMAAQ- I80800 JUN 5, 2024 12:57 PM +AAMAAQ- I10200 JUN 5, 2024 12:57 PM U.S. FOOD SERVICE 835 SAN JOSE OGDEN, UTAH 84401 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162725 162917 2 INTERSTITIAL BD 199912 200110 3 UNUSED 15000000 15000000 4 UNUSED 15000000 15000000 5 UNUSED 15000000 15000000 6 UNUSED 15000000 15000000 7 UNUSED 15000000 15000000 8 UNUSED 15000000 15000000 9 UNUSED 15000000 15000000 10 UNUSED 15000000 15000000 11 UNUSED 15000000 15000000 12 UNUSED 15000000 15000000 13 UNUSED 15000000 15000000 14 UNUSED 15000000 15000000 15 UNUSED 15000000 15000000 16 UNUSED 15000000 15000000 COMM 1 UNUSED 15000000 15000000 COMM 2 SERIAL SAT BD 478011 478708 COMM 3 SERIAL SAT BD 484692 478310 COMM 4 UNUSED 15000000 15000000 COMM 5 UNUSED 15000000 15000000 COMM 6 UNUSED 15000000 15000000 +AAM-