Loading...
HomeMy WebLinkAboutDDW-2024-011100System Number 27073 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - 175 Number of other connections - - - 13 ERCs of other connections 75.0 Total Equivalent Residential Connections (ERCs)250.0 gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 800 138.9 400 100,000 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >160 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >91%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.10 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >0.00 2 Irrigation zone 6 3 4 5 6 gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 706 78.4 496 79,424 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 1,000 Maximum fire suppression duration (in hours) for water system or pressure zone 2 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >120,000 2. Summary of Water System Capacity Requirements gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 1,506 217.3 896 299,424 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity 217.3 gpm Existing Source Capacity 8,575.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 3946.4% MIN. REQUIREMENTS FOR INDOOR WATER USE MINIMUM REQUIREMENTS FOR WATER SYSTEM Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* Source MIN. REQUIREMENTS FOR IRRIGATION USE System Name Source WCWCD - SandHollow Storage (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Storage Storage (indoor + outdoor + fire) This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Source (indoor + outdoor) Yes No Yes No Enter number of non-residential connections, e.g., 2 industrial connections. Convert "Number of other connections" (Cell E9) to ERCs here. [ERCs of other connections = peak day demand of other connections in gal per day / 800 gpd] Enter estimated irrigated acre per residential lot here. Enter total irrigated acres of other connections here. Enter fire flow in gpm. Enter duration in hours. Autolink to 4.2 "Total Existing Source Capacity" cell below. Select Irrigated Zone # from the pick list. See "Irrigation Demands & Map" tab on the bottom of the screen or WaterLink. Less than 100% indicates: (1) additional source capacity is needed, and (2) source deficiency should be assessed. Autolink to 2 "Total Source" cell above. Source deficit indicates that: (1) additional source capacity is needed, and (2) source deficiency should be assessed. WCD SandHollow Water System Capacity Calculation Sheet 2024 Page 1 of 3 9/12/2024 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage 299,424 gal Existing Storage Capacity 6,265,000 gal Storage Capacity Deficit None gal Required Fire Storage 120,000 gal Not Applicable Existing % of Total Req'd 2092.4% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs 60 12000 30 6000 15.00 0.0 20 4000 10 2000 5.00 0.0 5 1000 2.5 500 1.25 0 0.0 0 0.0 Number of people per camp site 200 Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served Vehicles served/day ERCs 0.0 0.0 0 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Total Existing Source Capacity (in gpm)8,575 4.1 Projected ERCs Calculation (optional)WS003 Well #9 1200 Total Projected ERCs WS004 Well #17 300 Existing Residential Connections WS006 Well #8 650 Obligated Future ERCs (enter below)WS007 Well #1 1500 WS008 Well #18 747 WS009 Well #19 600 WS012 Well #23 621 WS015 Hurricane Consective Connection WS016 Well #5 167 WS017 Well #6 247 WS018 Well #10 633 WS019 Well #4 Replacement 317 WS021 Well #11 340 WS022 Well #12 367 WS023 Well #13 453 WS024 Well #15 433 WS025 Quail Lake Consectivie Connection Maximum ERCs (assuming indoor use only)15435 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)6,265,000 ST001 Sky Ranch 140,000 ST002 Cliff Dwellers 125,000 ST003 I MG Reservoir 1,000,000 ST004 2 MG Resevoir 2,000,000 ST005 Warner Valley Tank 3,000,000(Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.) Facility Type Source MINIMUM REQUIREMENTS FOR INDOOR USE Modern Recreation Camp Semi-Developed Camp w/ flush toilets WCWCD - SandHollow Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Is storage deficiency solely due to fire storage? Storage Autolink to 4.3 "Total Existing Storage Capcity" cell below. If applicable, enter number of people per camp site here. Storage deficit indicates that: (1) additional storage volume is needed, and (2) storage deficiency should be assessed. Use this number in Cell I8 ("Number of residential connections") on Page 1 to calculate PROJECTED demand & req'ts (including both existing & future connections). Diaphragm or air pressure tanks shall NOT be considered effective storage volume for (1) community systems, or (2) NTNC with significant demand UNLESS an exception has been granted. Autolink to 2 "Total Storage" cell above. If applicable, use this number in cell I8 or cell I9 on Page 1. If NO, answer one of question set 2.01 to 2.05 in ESS.If YES, answer one of question set 2.06 to 2.10 in ESS. Less than 100% indicates: (1) additional storage capacity is needed, and (2) storage deficiency should be assessed. WCD SandHollow Water System Capacity Calculation Sheet 2024 Page 2 of 3 9/12/2024 WCD SandHollow Water System Capacity Calculation Sheet 2024 Page 3 of 3 9/12/2024