HomeMy WebLinkAboutDERR-2024-010728Annual Sump Inspection LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 9/16/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 8/26/2024 Order Number: 2364377 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: Jackson Foods #142 365 W. 7200 S. Midvale, UT 84047 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2364377 Date: 8/26/2024 Site Name/ID: Jackson Foods #142 / 142 Address: 365 W. 7200 S. City: Midvale State: UT Zip: 84047 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 T1 UNLEADED Pressure 50 11:31 12:31 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 T2 PREMIUM Pressure 50 11:31 12:31 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 T3 Low Sulfur Diesel Pressure 50 11:31 12:31 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Jackson Foods #142 365 W. 7200 S. Midvale UT 84047 142 Tanknology, Inc. JACKSONS FOOD STORES 3450 COMMERCIAL COURT MERIDIAN ID 83642 208-888-6061 08/26/2024 UNLEADED PREMIUM Red Jacket FX1V Red Jacket FX1V Red Jacket FX1DV 30 20 300 4 10 6 30 20 300 4 10 6 30 20 100 3 10 4 UT151 David Mathie NW1-2364377 Low Sulfur Diesel TUNLEADED:1 TPREMIUM:1 TDSL:1 Jackson Foods #142 JACKSONS FOOD STORES 365 W. 7200 S. Midvale UT 84047 142 Tanknology, Inc. 3450 COMMERCIAL COURT MERIDIAN ID 83642 208-888-6061 800-964-1250 08/26/2024 1 2 3 RUL PREM DSL EVO550 EV0550 EVO550 19703 14976 6847 117.75 117.75 92 UT151 David Mathie 365 W. 7200 S. Jackson Foods #142 365 W. 7200 S., Midvale, UT 84047 142 Tanknology, Inc. JACKSONS FOOD STORES 3450 COMMERCIAL COURT MERIDIAN, ID 83642 208-888-6061 08/26/2024 ANNULAR ANNULAR ANNULAR STP STP STP UDC RUL PREM DSL WET RUL PREM DSL 1/2 UT151 David Mathie 365 W. 7200 S. Jackson Foods #142 365 W. 7200 S., Midvale, UT 84047 142 Tanknology, Inc. JACKSONS FOOD STORES 3450 COMMERCIAL COURT MERIDIAN, ID 83642 208-888-6061 08/26/2024 UDC UDC UDC UDC 3/4 5/6 7/8 9/10 UT151 David Mathie Jackson Foods #142 365 W. 7200 S. Midvale, UT 84047 142 Tanknology, Inc. JACKSONS FOOD STORES 208-888-6061 08/26/2024 3450 COMMERCIAL COURT MERIDIAN, ID 83642 1 RUL 5 EBW 2 PREM 5 OPW 3 DSL 5 EBW 30 WC 1137 30WC 1142 5 MIN 0 30 WC 1143 30 WC 1144 1 MIN 0 30 WC 1147 30 WC 1152 5 MIN 0 UT151 David Mathie ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 8/26/2024 UST Facility Person Conducting Test Facility Name Jackson Foods #142 Facility ID # 142 Tester's Name DMATHIE Physical Address 365 W. 7200 S. Company Tanknology Inc. City Midvale County SALT LAKE State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner JACKSONS FOOD STORES Tester's Signature Date 8/26/2024 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2024 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:T1 UNLEADED - 1 NA N Y Y N Pass STP:T2 PREMIUM - 1 NA N Y Y N Pass STP:T3 Low Sulfur Diesel - 1 Y Y Y Y N Pass Comments: WO: 2364377 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2364377 Site ID / Name:142 / Jackson Foods #142 Address:365 W. 7200 S. City:Midvale State:UT Zip:84047