Loading...
HomeMy WebLinkAboutDDW-2024-011001System Number 25011 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -31 Number of other connections - - - 5 ERCs of other connections 5.0 Total Equivalent Residential Connections (ERCs)36.0 gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 800 20.0 400 14,400 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >31 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >100%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.20 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >20.00 2 Irrigation zone 3 3 4 5 6 gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 976 88.8 506 66,234 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 1,000 Maximum fire suppression duration (in hours) for water system or pressure zone 2 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >120,000 2. Summary of Water System Capacity Requirements gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 1,776 108.8 906 200,634 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity 108.8 gpm Existing Source Capacity 150.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 137.8% MIN. REQUIREMENTS FOR INDOOR WATER USE MINIMUM REQUIREMENTS FOR WATER SYSTEM Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* (Example: water use of 2 factories equals to water use of 55 homes.) Source MIN. REQUIREMENTS FOR IRRIGATION USE System Name Source Fairfield Culinary Water 2024 Storage (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Source (indoor + outdoor) Storage Storage (indoor + outdoor + fire) This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Yes No Yes No DDW-2021-039130 - 0901a06880f9c633 Page 1 of 2 8/9/2024 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage 200,634 gal Existing Storage Capacity 410,000 gal Storage Capacity Deficit None gal Required Fire Storage 120,000 gal Not Applicable Existing % of Total Req'd 204.4% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person* GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs 60 0 30 0 0.00 0 0.0 20 0 10 0 0.00 0 0.0 502.500.00 0 0.0 N/A 100 N/A 50 0.13 0 0.0 Number of people per camp site Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served Vehicles served/day ERCs 73.58.80 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Total Existing Source Capacity (in gpm)150 4.1 Projected ERCs Calculation (optional)WS001 Fairfield Spring (Inactive) 0 Total Projected ERCs 27 WS002 Fairfield Well 150 Existing Residential Connections 31 Obligated Future ERCs (enter below) Maximum ERCs (assuming indoor use only) 270 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)410,000 ST001 160K Tank 160,000 ST002 250K Tank 250,000 (Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.) RV Park Facility Type Source MINIMUM REQUIREMENTS FOR INDOOR USE Modern Recreation Camp Storage Semi-Developed Camp w/ flush toilets Fairfield Culinary Water 2024 Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Is storage deficiency solely due to fire storage? DDW-2021-039130 - 0901a06880f9c633 Page 2 of 2 8/9/2024