Loading...
HomeMy WebLinkAboutDDW-2024-010994Sanitary Survey - Deficiency Report PWS Number:UTAH17003 Deficiency Points:120 Survey Date:09/12/2024 Survey Name:LAKETOWN Surveyor:Matt Hinckley Sanitary Survey Category: SO SDWIS Severity Code: Significant Deficiency Management and Operations | DS001 | UTAH17003 DISTRIBUTION SYSTEM 26. For a community system serving 100 or more connections, at least 2 water sources are available. Rule: R309-515-4(3)Rule requires Community Water Systems serving more than 100 connections to have a minimum of two sources except where served by a water treatment plant. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:SEE EXCEPTION GRANTED. SYSTEM HAS BEEN RESEARCHING OPTIONS FOR AN ADDITIONAL SOURCE. Deficiency Points: 50 Days until points become effective on IPS: 120 SDWIS Deficiency Description: TGR7 COM SYSTEM SERVING 100 OR MORE CONNECTIONS LACKS REDUNDANT SOURCE Sanitary Survey Category: SM SDWIS Severity Code: Minor Deficiency Cross Connection and Operator Certification | DS001 | UTAH17003 DISTRIBUTION SYSTEM 35. Legally adopted authority statement Rule: R309-105-12(2)Rule requires each public water system to have a cross connection control program that includes a legally adopted and functional local authority to enforce the program (i.e., ordinance, bylaw, or policy). Notes:SYSTEM IS CURRENTLY WORKING ON AUTHORITY STATEMENT AND EXPECTS TO HAVE IT EXECUTED VERY SOON. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: M003 CCC-LACKS LOCAL AUTHORITY Sanitary Survey Category: SO SDWIS Severity Code: Significant Deficiency Springs | WS001 | LAKETOWN SPRING 64. No roots seen in collection boxes and junctions. Rule: R309-105-10(4)(a), R309-515-8(1)(a)Spring collection areas shall be periodically (preferably annually) cleared of deep- rooted vegetation to prevent root growth from clogging collection lines. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:THERE ARE ROOTS PRESENT IN THE LOWER JUNCTION BOX. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: SS08 ROOTS IN SPRING COLLECTION PIPES Sanitary Survey Category: FW SDWIS Severity Code: Minor Deficiency Storage Tanks | ST001 | STORAGE FACILITY ST001 79A. Mild deterioration or spalling? Rule: R309-545-6(1) and 545-9(1)Rule requires all water storage tanks to have suitable watertight roofs and sidewalls that shall also exclude birds, animals, insects, and excessive dust. Notes:THERE IS A SMALL CRACK/LEAK ON THE NORTHWEST CORNER OF THE TANK. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: V021 STORAGE TANK ROOF OR SIDEWALLS SHOW SIGNS OF MILD OR MODERATE DETERIORATION Sanitary Survey Category: FW SDWIS Severity Code: Minor Deficiency Storage Tanks | ST002 | STORAGE FACILITY ST002 93A. Mild deterioration or spalling? Rule: R309-545-6(1) and 545-9(1)Rule requires all water storage tanks to have suitable watertight roofs and sidewalls that shall also exclude birds, animals, insects, and excessive dust. Notes:THERE ARE A FEW SMALL CRACKS/LEAKS ON THE WEST WALL OF THE TANK. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: V021 STORAGE TANK ROOF OR SIDEWALLS SHOW SIGNS OF MILD OR MODERATE DETERIORATION