Loading...
HomeMy WebLinkAboutDDW-2024-010945DDW Reports <ddwreports@utah.gov> Fwd: Significant Deficiencies due this month #02010 1 message DDW IPS <ddwips@utah.gov>Mon, Sep 9 To: DDW Reports <ddwreports@utah.gov> Please import into the site visit folder title 02010 Def Corr 9-2024 ---------- Forwarded message --------- From: Julie Tanner <egrousecreekpipeline@gmail.com>Date: Tue, Sep 3, 2024 at 7:27 PM Subject: Re: Significant Deficiencies due this month #02010To: DDW IPS <ddwips@utah.gov> Hi Jen, We have addressed TD25 with a new chlorination system that utilizes gas instead of the tablets. I believe our engineer is working with Hunter Payne to close out this project. What photographdocumentation do you need to prove this has been done? We are still working with the rancher to resolve D009. This ranch has recently changed ownership and the trough has been turned off until we can get this resolved. D006 and D007 have been resolved. We replaced the Air/Vac Relief Valve in question. I have a picture of the new Air/Vac Relief Valve and the vault but didn't think to get a picture of the Vent Let me know what else you need. Thanks, Alan Smith System Manager On Tue, Aug 27, 2024 at 1:48 PM DDW IPS <ddwips@utah.gov> wrote: I hope this message finds you well. On September 9, 2020, East Grouse Creek Pipeline Co entered into a Compliance Agreement/Enforcement Order (CA/EO) with oextending the due dates for multiple significant deficiencies. This CA/EO was extended on August 18, 2023. The newly revised deadline agreed upon was August 18, Upon review, I have not found confirmation that the following significant deficiencies have been rectified: DS001 UTAH02010 DISTRIBUTION SYSTEM A 60 Hide Details ( 8 ) Code Description Severity Comments Determined Date Pending TD25 DISINFECTION IS REQUIRED BUT DISINFECTION IS INTERMITTENT OR NOT CONTINUOUS SIG Water system utilizes an unapproved method for disinfection. It consists of chlorine tablets in a PVC tube, with holes in the tube, which is then lowered into storage tank facility ST001. This PVC tube is inside the storage tank on a continuous basis. 09/16/2019 50 D009 WATER MAINS SUSCEPTIBLE TO NEARBY CONTAMINATION SOURCES SIG On 10-26-2022 there was a reported backflow incident where a stock tank backflowed into the water main.10/24/2022 50 D006 AIR RELIEF VALVE PIPE NOT DOWNTURNED SIG It was reported that the chamber does in fact flood meaning the outlet needs to be raised to at least 12" above grade.10/24/2022 25 D007 AIR RELIEF VALVE OR CHAMBER SUBJECT TO FLOODING SIG Chamber is reported to flood so drainage is not functioning.10/24/2022 25 9/13/24, 6:48 AM State of Utah Mail - Fwd: Significant Deficiencies due this month #02010 https://mail.google.com/mail/b/AEoRXRT4XtGzs3R9MT0jIULnNqFsIgfWaPJ1AwTWpAJKXGNSx_Zx/u/0/?ik=2401283fbe&view=pt&search=all&permt…1/2 If these issues have been addressed, please provide documentation outlining the corrective actions taken, along with any photographic evidence available. Alternativadditional time is required to address these deficiencies and you wish to discuss an extension of the CA/EO with our Division, please contact Colt Smith via emailat acsmith@utah.gov or by phone at 385-515-1529 at your earliest convenience. Thank you for your prompt attention to this matter. Jen -- Jennifer Yee IPS Rule Manager Environmental Scientist | Division of Drinking Water M: (385) 515-1501 drinkingwater.utah.gov (801) 536-4200 Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements. -- Jennifer Yee IPS Rule Manager Environmental Scientist | Division of Drinking Water M: (385) 515-1501 drinkingwater.utah.gov (801) 536-4200 Emails to and from this email address may be considered public records and thus subject to Utah GRAMArequirements. 2 attachments 20231214_152532 (1).jpg 3628K 20231214_132005 (1).jpg8282K 9/13/24, 6:48 AM State of Utah Mail - Fwd: Significant Deficiencies due this month #02010 https://mail.google.com/mail/b/AEoRXRT4XtGzs3R9MT0jIULnNqFsIgfWaPJ1AwTWpAJKXGNSx_Zx/u/0/?ik=2401283fbe&view=pt&search=all&permt…2/2