August 08,2024
MIKE BEAUPARLANT
RED MESA TRADING CO. INC
501 AIRPORT DR. SUITE 1OO
FARMINGTON, NM 87401
RE: Request for Petroleum Storage Tank Records
RED MESA EXPRESS #516, located at HWY 262, MONTEZUMA CREEK
Facility ldentification No. 5000329
Dear MIKE BEAUPARLANT
PST operators are required to ensure that certain tests are conducted for their tank system
Dates highlighted in "Yellow" - tests are due soon.
Dates highlighted in "Red" - tests are due and you are out of compliance.
Tank lD/Alt
ID
Description LTT Spill Bucket Tank or Flex ATG
LLD Overfill Pipe CP Sump
1/105-UGTA Gasol ine-Regular-6000
2t216-UGrA Gasoline-Premium-6000
3/217-UGTA Diesel-Diesel#2(U.L.S.)-6000
LTT - Line Tightness Test
LLD - Line Leak Detector
Overfill - Overfill Device
Tank or Flex/Pipe CP - Corrosion Tests
ATG - Automatic Tank Gauging
Sump - Tank Top Sump and applicable Dispenser Sumps
Please note that UDG tests are not listed, but are required on your facility's next sump test
cycle starting July 1 ,2023, if applicable. Also, effective immediately pressure vent valves
must be tested every three years for gasoline tanks.
Please submit a copy of the required tests to the DERR within 30 days of the date due.
lf you have any questions please call David Wilson at 801-536-4100.
N/A
N/A
912312024
N/A
N/A
N/A
N/A
N/A
N/A
N/A
9123t2024
N/A
N/A
N/A
N/A
N/A
N/A
N/A
912312024
N/A
N/A
N/A
N/A
N/A
Statc ol Utah
SPEI.JCEq J COX
(-irt *,tn'tr
DE!DRE HENDEPSOI,
l.t, il!t tt,.tttI {. /,t t'rit)
d)PEt/RPl200-19
APPENDIX C.3
Facility Name: Red Mesa Express #516 Owner: Red mesa Trading Co.
Address: U$ Hwy.262 & lH 35 Address: 501 Airport Dr. ste 100
City, State, Zip Code: Montezuma Creek,UT. 95434 City, State, Zip Code: Farmington,N.M. 87401
Facility l.D. #: 5000329 Phone #: 505 326 5571
Testing Company: BioTech Remediation lnc.Phone #:Dale: 8-1-24
This procedure is to test the leak integrity of single and double-walled spill buckets. See PEl,zRPl2OO Section 6.2 for hydrostatic test
method, Section 6.3 for single-walled vacuum test method and Section 6.4 for double-walled vacuum test method.
Tank Number #1 #2 #3
Product Stored UL/R UL/S DSL
Spill Bucket
Capacity 5 Gal.5 Gal.5 Gal
Manufacturer EBW EBW OPW,1C series
Construction m Single-walled
! Double-walled
E Single-walled
E Double-walled
E Single-walled
I Double-walled
n Single-walled
n Double-walled
n Single-walled
E Double-walled
n Single-walled
I Double-walled
Test Type B Hydrostatic
n Vacuum
! Single-walledI Double-walled
m Hydrostatic
D Vacuum
D Single-walled
n Double-walled
K Hydrostatic
n Vacuum
n Single-walled
n Double-walled
n Hydrostatic
D Vacuum
n Singlewalled
E Double-walled
I Hydrostatic
D Vacuum
D Single-walled
D Double-walled
E Hydrostatic
! Vacuum
n Single-walled
n Double-walled
Spill Bucket Type E Product
E Vapor
E Product
! vapor
DI Product
D Vapor
! Product
D Vapor
n Product
nVapor
I Product
n Vapor
Liquid and debris
removed from
spill bucket?*
XYes DNo ElYes nNo ElYes DNo trYes flNo trYes ! No nYes nNo
Visual lnspection
(No cracks, loose
parts or separa-
tion of the bucket
from the fill pipe.)
E Pass n Fail El Pass n Fail E Pass D Fait D Pass tr Fail fl Pass ! Fail tr Pass tr Fail
Tank riser cap
included in test?
EYes nNo
!NA
EYes nNo
f] NA
ElYes tr No
trNA
flYes ENo
trNA
EYes ENo
NNA
flYes nNo
trNA
Drain valve
included in test?
EYes n No
trNA
DIYes n No
NNA
EYes E No
NNA
nYes DNo
DNA
DYes trNo
DNA
trYes DNo
trNA
Starting Level 9"8'11.25"
Test Start Time 10:25 10:2Q
Ending Level 9.8"11.25"
Test End Time 11:45 12:15 11:45
Test Period '1 Hr 20 min 1Hr,t hr 25 min
Level Change 0"0'0'
Pass/fail criteria: Must pass visual inspection. Hydrostatic: Water level drop of less than 1il8 inch; Vacuum single-walled only:
Maintain at least 26 inches water column; Vacuum double-walled: maintain at least 12 inches water column.
Tegt Reeults E Pass I Fait Ei Pass X Fail E Pass n Fail I Pass D Fait D Pass n Fail n trPass
Drain valve in UL/S spill bucket not seating properly, remove drain valve assembly and clean o-ring and plunger
and reinstall.
Comments:
SPILL BUCKET INTEGRITY TESTING HYDROSTATTC TEST METHOD
SINGIE. AND DOUBLE.WALLED VACUUM TEST METHOD
*All liquids and debris must be
Tester's Name (print)
pei.org@
M,re
of properly.
Tester's Signatu