Loading...
HomeMy WebLinkAboutDERR-2024-010629GEORGE STURM UTAH STATE FUEL NETWORK 4315 S 2700 W SALT LAKE CITY, UT 84129 RE:Request for Petroleum Storage Tank Records UNIVERSITY HOSPITAL, located at 50 N MEDICAL DR, SALT LAKE CITY Facility Identification No. 4000303 Dear GEORGE STURM: PST operators are required to ensure that certain tests are conducted for their tank system. Dates highlighted in "Yellow" - tests are due soon. Dates highlighted in "Red" - tests are due and you are out of compliance. Tank ID/Alt ID Description LTT -------------------- LLD Spill Bucket -------------------- Overfill Tank or Flex -------------------- Pipe CP ATG -------------------- Sump 20/20 Diesel-Diesel #2 (U.L.S.)-35000 N/A N/A N/A 8/30/2024 N/A N/A N/A N/A LTT - Line Tightness Test LLD - Line Leak Detector Overfill ±Overfill Device Tank or Flex/Pipe CP - Corrosion Tests ATG ±Automatic Tank Gauging Sump - Tank Top Sump and applicable Dispenser Sumps Please note that UDC tests are not listed, but are required on your facility's next sump test cycle starting July 1, 2023, if applicable. Also, effective immediately pressure vent valves must be tested every three years for gasoline tanks. Please submit a copy of the required tests to the DERR within 30 days of the date due. If you have any questions please call DeAnn Rasmussen at 801-536-4100. 195 North 1950 West - Salt Lake City, UT Mailing Address: - P.O. Box 144840 - Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 - Fax (801) 359-8853 - T.D.D. (801) 536-4414 www.deq.utah.gov Printed on 100% recycled paper August 08, 2024 State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 TEI 5000 NON VOLUMETRIC, TEI 4000 VOLUMETRIC, TEI ULLAGE, TEI LT3 PRECISION TANK & LINE TEST RESULTS SUMMARY INVOICE ADDRESS:TANK LOCATION: WORK ORDER # TECH # 94027 TECHNICIAN: SM STATE TECH # STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 UNIVERSITY OF UTAH HOSPITAL GENERATOR TANK (EAST SIDE) SALT LAKE CITY, UTAH 24093 UT 0121 DATE: 9-5-2024 TIME START: 11:00 TIME END: 14:00 GROUNDWATER DEPTH: N/A DW TANK TANK CAPACITY 35815 PRODUCT DSL TANK PASS VENT PASS PRODUCT LINE PASS LINE LEAK DETECTOR N/A WATER IN TANK 0.0" PUMP TYPE PRESS TANK MATERIAL DWF1. 2. 3. 4. 5. 6. PRODUCT LINES TESTED AT 50 PSI FOR 15 MIN LINE RATES (GPH) 1. 2. 3. 5. 6. SUPPLY -.011 ADDITIONAL INFORMATION:TANK CERTIFIED WITH TANK INTERSTICIAL TEST AND TANK ULLAGE TEST. RETURN LINE TESTED WITH TANK CERTIFIED TECHNICIAN SIGNATURE:DATE:9-5-2024 These systems meet all requirements set forth by USEPA 40 CFR and has received third party certification. 4. TEST METHODS USED FOR THIS LOCATION TEI 5000 NON VOLUMETRIC TANK TEST TEI 4000 VOLUMETRIC TANK TEST TEI TANK ULLAGE TEST TEI LT3 LINE TESTX X LINE LEAK DETECTOR TYPE & SIMULATED LEAK RATE 1. 2. 3. M = MECHANICAL E = ELECTRONIC # = (GPH) RATE 4. 5. 6. All tests were performed according to manufacturer protocol, and within the common practices of the industry. However due to the variables of tightness testing, these results cannot be guaranteed. There are no warranties expressed, written or implied. DEQ ID#4000303 Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.09.08 17:14:04 -07'00' Reason: I am the author of this document UNIVERSITY OF UTAH HOSPITAL GENERATOR TANK ( EAST SIDE ) SALT LAKE CITY, UTAH 4000303 APPLIED ENVIRONMENTAL SERVICES STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 9-5-2024 STP SUMP S DSL X X X X X X X X STP SUMP N DSL X X X X X X X X OUTSIDE VISUAL ALARM ON TANK MONITOR FUNCTIONS PROPERLY STEVEN B MARTIN APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 AESUTAH@AOL.COM Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.09.08 17:15:33 -07'00' Reason: I am the author of this document AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: Owner: Address: City, State, Zip Code: Phone # Testers Phone # Date: This procedure is to determine whether the ( ATG) is operating properly. See PEI/RP1200 Section 8.2 for the proper inspection procedure. This procedure is applicable to tank level monitor stems that touch the botom of the tank when in place. Tank Number Product Stored: ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, has it been inspected and any damaged or missing parts replaced? 4. Float moves freely on the stem without 5. Fuel float level agrees with the value programmed into the console? 6. Water float level agrees with the value programmed into the console? 7. Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the float alarm activates corresponds with value programmed in the gauge? If any answers in Lines 3,4,5, or 6 are "NO" the system has failed the test. TEST RESULTS Comments: Testers Name: Steven B. Martin Testers Signature: UNIVERSITY OF UTAH HOSPITAL GENERATOR TANK (EAST SIDE) SALT LAKE CITY, UTAH 4000303 APPLIED ENVIRONMENTAL, L.C. STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 9-5-2024 1 DSL TLS-350 35815 134.5 YES YES YES YES 114.5 YES 2.0 YES PASS BATTERY BACKUP FUNCTIONS PROPERLY SUMP SENSORS FUNCTION PROPERLY Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.09.08 17:17:01 -07'00' Reason: I am the author of this document