Loading...
HomeMy WebLinkAboutDERR-2024-010615EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 08/05/2024 9000153 Top Stop C-66 1128 W. Hwy. 40 Roosevelt, UT 84066 473-753-1025 Jess Kuddes Max LaRou UT-412 60 P.S.I. REG 0 78 15 78 0 0 0 30 78 0 0 0 PASS PRM 0 64 15 64 0 0 0 30 64 0 0 0 PASS DSL, Sats. 10-12 0 43 15 43 0 0 0 30 43 0 0 0 PASS 08/05/2024 Max LaRou UT-412 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV 0//' DQGHOHFWURQLFOLQHOHDNGHWHFWRUV (//' ZLWKVXEPHUVLEOH WXUELQHSXPS 673 V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\ PO  OLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGV WLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH 673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGV WKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHW WULS ZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB  Precision Testing Technologies Inc.801-886-9224 Top Stop C-66 1128 W. Hwy. 40 Roosevelt, UT 84066 9000153 Wind River Petroleum 5097 S. 900 E. Ste. 200 S.L.C., UT 84117 435-753-1025 08/05/2024 Q1 REG V.R. PLLD 4 32 2 4 4 4 Q2 PRM V.R. PLLD 4 31 2 4 4 4 Q3 DSL V.R. PLLD 4 38 N.A. 4 4 4 Max LaRou UT-412 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Top Stop C-66 9000153 1 REG V.R. TLS 350 11,608 90.5 4 4 4 4 76 4 2 4 4 2 PRM V.R. TLS 350 7,899 90.5 4 4 4 4 75 3/4 4 2 4 4 3 DSL V.R. TLS 350 11,608 90.5 4 4 4 4 76 4 2 4 4 Max LaRou UT-412 08/05/2024 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Top Stop C-66 9000153 08/05/2024 REG Int. REG 4 Lift 4 4 4 4 4 4 PRM, DEF Int. PRM, DEF 4 Lift 4 4 4 4 4 4 DSL Int. DSL 4 Lift 4 4 4 4 4 4 REG STP REG 4 4 4 4 4 4 4 4 PRM STP PRM 4 4 4 4 4 4 4 4 DSL STP DSL 4 4 4 4 4 4 4 4 Disp. 1/2 Lines 4 4 4 4 4 4 4 4 Max LaRou UT-412 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Top Stop C-66 9000153 08/05/2024 Disp. 3/4 Lines 4 4 4 4 4 4 4 4 5/6 Lines 4 4 4 4 4 4 4 4 7/8 Lines 4 4 4 4 4 4 4 4 9/10M DSL 4 4 4 4 4 4 4 4 10S/11M DSL 4 4 4 4 4 4 4 4 11S/12M DSL 4 4 4 4 4 4 4 4 12S DSL 4 4 4 4 4 4 4 4 Max LaRou UT-412 Pressure/Vacuum (P/V) Vent Valve Data Sheet Facility Name: Test Date: Address: Test Company: Precision Testing Technologies City: Tester Name: Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): 2.5" to 6" wc <=0.05 cfh @ 2" wc 2.5" to 6" wc <=0.05 cfh @2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc Top Stop C-66 08/05/2024 Max LaRou UT-412 REG OPW 623V 4 0.03 cfh @ 2"wc 4.4"wc 0.17 cfh @ 4"wc -9.0"wc PRM OPW 623V 4 0.04 cfh @ 2"wc 4.7"wc 0.19 cfh @ 4"wc -7.2"wc Top Stop C-66 Max LaRou UT-412 08/05/2024