Loading...
HomeMy WebLinkAboutDSHW-2024-008126Site Information Finalized Yes Facility Name NUERA Bayview MSW Landfill Facility_ID SW0118 Facility Name NUERA Bayview MSW Landfill Street Address 10800 S. State Road 68 City Elberta ZIP Code 84633 County Utah County Inspection Date 08-29-2024 Type of Visit Routine Oversite Is the Visit Announced?Yes 40.553582, -111.873428 Weather Conditions Sunny and 65 degrees Inspection Goal Landfill Facility Contact Jared Maughan Participants Jared Maughan, Steve Dansey, and Matt Sullivan Follow Up Inspection Needed?N/A Recommended Follow Up Date Depart Office Date 08-29-2024 Depart Office time 09:00 AM (-6 GMT) Return to Office Date 08-29-2024 Return to Office time 03:30 PM (-6 GMT) 1. Pre-Inspection Review 1.1 Permit Review Yes Comment 1.2 Annual Report Review Yes Comment 1.3 Previous Inspection Review Yes Comment 1.4 Facility Contacts Confirmed Yes Comment Date Submitted: 09-03-2024 11:55 AM Submitted By: msullivan@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 1 of 7 1.5 Facility Contacted (If an announced inspection) Yes Comment 1.6 Local Health Contacted Yes Comment 1.7 Other Comment 2. Facility / Operational Controls (1-Good, 5-Poor) 2.1 Litter 1 2.2 Roads 1 2.3 Gate House Operations 1 2.4 Vectors 3 2.5 Communications 1 2.6 Recycling Area NA 2.7 Fugitive Dust Control 1 2.8 Waste Inspection Area 1 2.9 Scavenging Control 1 2.10 Open Burning NA 2.11 Fences, Gates, Locks, Access Control 1 2.12 Working Face 1 2.13 Daily - Soil 3 2.14 Daily - Alternative NA 2.15 Leachate Collection System 1 2.16 Other Comment (Required)Seagulls at and around disposal cell. Owner has scheduled a falconer to flush out seagulls. Some areas outside of the working face needed more daily cover 3. Signs Required / Properly Posted 3.1 Operating Days / Hours Yes 3.2 Directions & Procedures Yes 3.3 Emergency Numbers Yes 3.4 List of Unacceptable Materials Yes 3.5 Other Yes Comment (Required)Facility was open during the inspection Date Submitted: 09-03-2024 11:55 AM Submitted By: msullivan@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 2 of 7 4. Operator / Representative / Employees 4.1 On-site While Open Yes 4.2 Training Yes 4.3 Other Comment (Required)Good training records 5. Monitoring 5.1 Methane Yes 5.2 Random Inspections Yes 5.3 Leachate Yes 5.4 Ground Water Yes 5.5 Other Comment (Required)Records were complete 6. Drainage / Erosion 6.1 Water Run-on Yes 6.2 Water Run-off Yes 6.3 Other Comment (Required)Water runoff and run on controls are regularly monitored 7. Proper Storage / Isolation / Disposal 7.1 Special Waste Yes 7.2 Batteries Yes 7.3 Hazardous Waste Yes 7.4 Infectious Waste Yes 7.6 Dead Animals Yes 7.7 Asbestos Yes 7.8 Bulky Waste Yes 7.9 Contaminated Soil Yes 7.10 Ash Yes 7.11 Sludge Yes 7.12 Other Comment (Required)Batteries are usually separated prior to arriving at the landfill. If some are found, they are separated from the solid waste and appropriately managed. Small household hazardous waste may be accepted. 8. Cover Date Submitted: 09-03-2024 11:55 AM Submitted By: msullivan@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 3 of 7 8.1 Intermediate Yes 8.2 Final Yes 8.3 Vegetation Yes 8.4 Other Comment (Required)Some spots needed more daily cover outside of the working face 9. Inspection Records 9.1 Random Inspection Report Yes 9.2 Gas Monitoring System Yes 9.3 Surface Drainage Control Yes 9.4 Daily Records Yes 9.5 Weight or Volumes Yes 9.6 Intermediate Cover Yes 9.7 Final Cover Yes 9.8 Self Inspection (Quarterly Reports) Yes 9.9 Deviation From Plans N/A 9.10 Permit, Permit Application, and Rules Available Yes 9.11 Other Comment (Required)Records were reviewed and in order 10. Monitoring / Sampling / Analysis Records 10.1 Explosive Gas Monitoring Yes 10.2 Leachate Sampling & Treatment Yes 10.3 Ground Water Sampling Results Yes 10.4 Other Comment (Required)Good recordkeeping 11. Special Waste Records 11.1 Lab Analysis Results Yes 11.2 Manifests Yes 11.3 Treatment Certification Yes 11.4 Paint Filter Test Results Yes 11.5 Onsite Treatment Documentation Date Submitted: 09-03-2024 11:55 AM Submitted By: msullivan@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 4 of 7 11.6 Other Comment (Required)Sludge has paint filter test results 12. Waste Tires 12.1 Acceptance procedures for Waste Tires N/A 12.2 Waste Tire Pile Segregated N/A 12.3 Estimated Quanitity of Waste Tires No Number of Tires 12.4 Waste Tire Fund Training N/A Comment (Required)Not accepted 13 Other Items 13.1 Notice of Inspections Form Completed and Signed Yes 13.2 13.3 13.4 Comment (Required)Monthly site inspection 14. Special Permit Requirements 14.1 14.2 14.3 Comment (Required)NA General Comments Comments Some litter on slopes where soil and solid waste was excavated to emplace lateral gas lines. This solid waste will be covered back up. DWMRC Inspector Signature DWMRC Inspector Name Matt Sullivan Date/Time 08-30-2024 Photos Date Submitted: 09-03-2024 11:55 AM Submitted By: msullivan@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 5 of 7 Attach Photos Landfill entrance Signs through out the facility premises Daily working face View of future cells looking west Date Submitted: 09-03-2024 11:55 AM Submitted By: msullivan@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 6 of 7 Closer view of future cells with high fencing on the south side. High fencing is also on the north and east sides. Date Submitted: 09-03-2024 11:55 AM Submitted By: msullivan@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 7 of 7