Loading...
HomeMy WebLinkAboutDERR-2024-010495Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name KAMAS VALLEY CO OP Address 3186 N SR 32 MARION, UT 84036 Contact KAMAS VALLEY CO OP Phone Email kamascoop@yahoo.com TANK LOCATION Name KAMAS VALLEY CO-OP Address 3186 N SR 32 MARION, UT 84036 A Operator None Phone None B Operator SAME Phone SAME Facility ID: 7000024 Inspection Date: 09/04/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST TANK DETAILS Tank ID/Alt ID 2 / 2 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc April 1, 2011 / 8000 / Substance Stored Gasoline / Regular Tank Material- Mod Asphalt Coated or Bare Steel- Secondary Containment ATG / LTT Test None LLD Test None Pipe Material- Mod Flexible Plastic / None Pipe type/STP Cont Gravity Feed / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Overfill alarm / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankTightness / TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None Tank ID/Alt ID 3 / 3 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc April 1, 2011 / 5500 / Substance Stored Diesel / Tank Material- Mod Asphalt Coated or Bare Steel- Secondary Containment ATG / LTT Test None LLD Test None Pipe Material- Mod Fiberglass Reinforced Plastic / Double-Walled Pipe type/STP Cont Gravity Feed / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Overfill alarm / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankTightness / TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None 2024-09-04 Page 1 of 4 Tank ID/Alt ID 4 / 4 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc April 1, 2011 / 7500 / Substance Stored Diesel / Off-road Diesel Tank Material- Mod Asphalt Coated or Bare Steel- Secondary Containment ATG / LTT Test None LLD Test None Pipe Material- Mod Fiberglass Reinforced Plastic / Double-Walled Pipe type/STP Cont Gravity Feed / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Overfill alarm / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankTightness / TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-09-04 Page 2 of 4 FACILITY RESPONSES Financial Responsibility Financial responsibility method is ok?Yes The above accurately represents the facility's release detection records Yes TANK RESPONSES Tank 3 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 2 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 4 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes DISPENSER RESPONSES MONTHLY LEAK DETECTION MONITORING Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Mar '24 Apr '24 May '24 Jun '24 Jul '24 Aug '24 Tank 2 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 3 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 4 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS All items are in compliance. 2024-09-04 Page 3 of 4 Prepared by fueloperator.com Inspection Information Inspector:Harris, Gary Record Created:Sept. 4, 2024, 12:08 p.m. Inspection Date:Sept. 4, 2024 2024-09-04 Page 4 of 4