HomeMy WebLinkAboutDERR-2024-010382APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 TEI 5000 NON VOLUMETRIC, TEI 4000 VOLUMETRIC, TEI ULLAGE, TEI LT3 PRECISION TANK & LINE TEST RESULTS SUMMARY INVOICE ADDRESS:TANK LOCATION: WORK ORDER # TECH # 94027 TECHNICIAN: SM STATE TECH # STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 GRANITE EDUCATION CENTER 2500 SOUTH MAIN SALT LAKE CITY, UTAH 84115 24086 UT 0121 DATE: 8-21-2024 TIME START: 11:00 TIME END: 16:00 GROUNDWATER DEPTH: N/A DW TKS TANK TANK CAPACITY 11527 11527 PRODUCT DSL DSL TANK PASS PASS VENT PASS PASS PRODUCT LINE PASS PASS LINE LEAK DETECTOR NONE N/A WATER IN TANK 0.0" 0.0" PUMP TYPE PRESS SUCTION TANK MATERIAL DWF DWF 1. 2. 3. 4. 5. 6. PRODUCT LINES TESTED AT 50 PSI FOR 15 MIN LINE RATES (GPH) 1. 2. 3. 5. 6. DSL -.010 ADDITIONAL INFORMATION:TK1 GOES TO BOILER, TK2 GOES TO GENERATOR SUCTION LINE FOR GENERATOR TESTED WITH TANK. CERTIFIED TECHNICIAN SIGNATURE:DATE:8-21-2024 These systems meet all requirements set forth by USEPA 40 CFR and has received third party certification. 4. TEST METHODS USED FOR THIS LOCATION TEI 5000 NON VOLUMETRIC TANK TEST TEI 4000 VOLUMETRIC TANK TEST TEI TANK ULLAGE TEST TEI LT3 LINE TESTX X LINE LEAK DETECTOR TYPE & SIMULATED LEAK RATE 1. 2. 3. M = MECHANICAL E = ELECTRONIC # = (GPH) RATE 4. 5. 6. All tests were performed according to manufacturer protocol, and within the common practices of the industry. However due to the variables of tightness testing, these results cannot be guaranteed. There are no warranties expressed, written or implied. DEQ ID#4001977 Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.08.24 14:39:44 -07'00' Reason: I am the author of this document UST OVERFILL EQUIPMENT INSPECTION AUTOMATIC SHUTOFF DEVICE AND BALL FLOAT VALVE Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: This data sheet is for inspecting automatic shutoff devices and ball float valves. See PEI/RP 1200, Section 7 for inspection procedures. Owner: Address: City, State, Zip Code: Phone# Tester Phone# Product Grade: Tank Number: Tank Volume, gallons: Tank Diameter, inches: Overfill Prevention Device Brand: Overfill Type AUTOMATIC SHUTOFF DEVICE INSPECTION 1. Drop tube removed from tank? 2. Drop tube and float mechanisms are free of debris? 3. Float moves freely without binding and poppet moves into flow path? 4. Bypass valve in the drop tube is open and free of blockage (if present)? 5. Flapper is adjusted to shut off flow at 95% ?* A "NO" to any item in Lines 1-5 indicates a test failure. BALL FLOAT VALVE INSPECTION * * 1. Tank top fittings are vapor-tight and leak free? 2. Ball float cage free of debris? 3. Ball free of holes and cracks and moves freely in cage? 4. Vent hole in pipe open and near top of tank? 5. Ball float pipe is proper length to restrict flow at 90% capacity?*** A "NO" to any item in Lines 1-5 indicates a test failure. Test Results: * Use manufacturer's suggested proceedure for determining if automatic shutoff device will shut off flow at 95% capacity. Tester's Name: GRANITE EDUCATION 2500 SOUTH MAIN SALT LAKE CITY, UTAH 4001977 AES UTAH LICENCE # UT 0121 STATE FUEL NETWORK PO BOX 841152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 Date: 8-21-2024 DSL 1 11527 90 OPW 71SO AUTOMATIC YES YES YES YES DSL 2 11527 90 OPW71SO AUTOMATIC YES YES YES YES Steven B. Martin Testers Signature: * * If a ball float is found to fail the inspection , another method of overfill must be used. * * * Use manufacturer's suggested procedure for determining if flow restriction device will restrict flow at 90% capacity. Comments PASS PASS Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.08.24 16:44:20 -07'00' Reason: I am the author of this document GRANITE EDUCATION BUILDING 2500 SOUTH MAIN SALT LAKE CITY, UTAH 4001977 APPLIED ENVIRONMENTAL SERVICES STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-6-2-4872 801-540-9258 8-21-2024 STP SU DSL X X X X X X X X PIP SU DSL X X X X X X X X SENSORS TRIGGER AUDIBLE AND VISUAL ALARM STEVEN B MARTIN APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 AESUTAH@AOL.COM Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.08.24 14:41:23 -07'00' Reason: I am the author of this document SPILL PREVENTION TEST Spill Bucket Hydrostatic Test Form Facility Name Facility ID Address Tester's Name Test Date Phone Tank Number Product Stored Capacity Manufacturer Construction Liquid and Debris Removed Visual Inspection No cracks, holes, or separations Tank Riser Cap Included in Test Is Drain Valve Included in Test Start Level Start Time Ending Level End Time Test Period (minimum of 1 hour) Change in Level Test Results Photos indicating water Levels are Attached? Pass / Fail Criteria: Must pass visual inspection, test duration at least one hour, must include photos with this form, water level drop of less than 1/8 inch. Ref: PEI / RP 1200 6.2.5 Test Procedure How was Liquid Disposed? Comments I certify under penalty of law that the above information is true, accurate and complete Tester's Signature GRANITE EDUCATION 4001977 2500 SOUTH MAIN SALT LAKE CITY, UTAH STEVEN MARTIN AES TESTING 8-21-2024 801-540-9258 1 DSL 5 EBW DW YES PASS NO YES 13 1/2 12:45 13 1/2 13:45 1 HR 0 PASS NO 2 DSL 5 EBW DW YES PASS NO YES 13 7/8 12:45 13 7/8 13:45 1 HR 0 PASS NO REUSED UTAH TESTER UT 0121 Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.08.24 16:42:27 -07'00' Reason: I am the author of this document AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: Owner: Address: City, State, Zip Code: Phone # Testers Phone # Date: This procedure is to determine whether the ( ATG) is operating properly. See PEI/RP1200 Section 8.2 for the proper inspection procedure. Tank Number Product Stored: ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, has it been inspected and any damaged or missing parts replaced? 4. Float moves freely on the stem without 5. Fuel float level agrees with the value programmed into the console? 6. Water float level agrees with the value programmed into the console? 7. Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the float alarm activates corresponds with value programmed in the gauge? If any answers in Lines 3,4,5, or 6 are "NO" the system has failed the test. TEST RESULTS Comments: Testers Name: Steven B. Martin Testers Signature: GRANITE EDUCATION BUILDING 2500 SOUTH MAIN SALT LAKE CITY, UTAH 4001977 AES UTAH TESTER # UT 0121 STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 8-21-2024 1 DSL TLS 300C 11527 92 YES YES YES YES 76 YES 2.0 YES 2 DSL TLS 300C 11527 92 YES YES YES YES 76 YES 2.0 YES PASS PASS BATTERY BACKUP FUNCTIONS PROPERLY BOTH SUMP SENSORS FUNCTION PROPERLY, SENSORS TRIP AUDIBLE AND VISUAL ALARM Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.08.24 16:45:53 -07'00' Reason: I am the author of this document