Loading...
HomeMy WebLinkAboutDERR-2024-010338Annual Sump Inspection PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 8/24/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 7/30/2024 Order Number: 2372539 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: Jackson Foods #161 1567 S. Creek Meadow Rd. Riverton, UT 84065 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :Jackson Foods #161 Name :TANKNOLOGY INC. Address :1567 S. Creek Meadow Rd. Riverton, UT 84065 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :-Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :4 Products per Nozzle :1 Tanks Manifolded ?No Drop-Out tank present?N0 Total # of Tanks Tested :1 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) 4 E-FREE REG - CONV(E0) 9753 1965 7788 12:30 2.00 2.00 2.00 2.00 2.00 2.00 1.88 Pass Total 9753 1965 7788 All Comments: Tester :David Mathie Test Date :7/30/2024 Signature :Work Order :2372539 WO: 2372539 PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.47 Pass Neg Leak Rate (CFH)0.21 17 0.0360 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -6.86 Pass PVVC tested ==>PREM Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.52 Pass Neg Leak Rate (CFH)0.21 16 0.0339 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -6.90 Pass PVVC tested ==>EFREE Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.53 Pass Neg Leak Rate (CFH)0.21 15 0.0318 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -6.86 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0339 Total -ve LR: 0.1017 Test Date 7/30/2024 Technician Name David Mathie WO #2372539 Facility Name / Loc #Jackson Foods #161 161 Street 1567 S. Creek Meadow Rd. City, St, Zip Riverton, UT 84065 Pressure Vacuum Vent Cap Test Form TP-201.1E ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 7/30/2024 UST Facility Person Conducting Test Facility Name Jackson Foods #161 Facility ID # 161 Tester's Name DMATHIE Physical Address 1567 S. Creek Meadow Rd. Company Tanknology Inc. City Riverton County SALT LAKE State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner JACKSONS FOOD STORES Tester's Signature Date 7/30/2024 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2024 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:1 RUL - 1 Y Y Y Y N Pass STP:2 PREMIUM - 1 Y Y Y Y N Pass STP:3 Low Sulfur Diesel - 1 Y Y Y Y N Pass STP:4 E-FREE REG - CONV(E0) - 1 Y Y Y Y N Pass Comments: WO: 2372539 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2372539 Site ID / Name:161 / Jackson Foods #161 Address:1567 S. Creek Meadow Rd. City:Riverton State:UT Zip:84065