Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2024-010257
IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 8/23/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 8/21/2024 Order Number: 2370466 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN 16449, MKT 1606 3720 EAST 7000 SOUTH State ID 4000998 SALT LAKE CITY, UT 84121 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 7-ELEVEN 16449, MKT 1606 3720 EAST 7000 SOUTH State ID 4000998 SALT LAKE CITY UT 84121 16449 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 08/21/2024 RUL Low Sulfur Diesel Vaporless LD- 2000 Vaporless LD- 2000 Vaporless LD- 2000 30 30 130 4 20 5 30 30 130 2 20 3 30 30 70 2 20 3 UT151 David Mathie NW1-2370466 PUL TTNK4 REGULAR:1 TTNK5 DIESEL:1 TTNK6 PREMIUM:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2370466 Date:8/21/2024 Site Name/ID:7-ELEVEN 16449, MKT 1606 Address:3720 EAST 7000 SOUTH State ID 4000998 City:SALT LAKE CITY State:UT Zip:84121 How Inspected: Line Test NFPA 30A PEI RP1200 Other STP PRESSURE Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 40 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN 16449, MKT 1606 7-ELEVEN, INC. 3720 EAST 7000 SOUTH State ID 4000998 SALT LAKE CITY UT 84121 4000998 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 08/21/2024 4 5 6 RUL DSL PUL VR350 VR350 VR350 19782 11904 7901 118.37 118.37 118.37 UT151 David Mathie 3720 EAST 7000 SOUTH State ID 4000998 7-ELEVEN 16449, MKT 1606 3720 EAST 7000 SOUTH State ID 4000998, SALT LAKE CITY, UT 8412116449 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 08/21/2024 ANNULAR ANNULAR FILL STP FILL STP FILL RUL PUL/DSL RUL RUL PUL PUL DSL UT151 RUL FILL SENSOR IN ALARM CLEARED AND RETESTED WAITING FOR MANTIANCE TO CLEAN OUT David Mathie 3720 EAST 7000 SOUTH State ID 4000998 7-ELEVEN 16449, MKT 1606 3720 EAST 7000 SOUTH State ID 4000998, SALT LAKE CITY, UT 8412116449 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 08/21/2024 DSL UDC UDC UDC STP 1/2 3/4 5/6 UT151 David Mathie 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-ELEVEN 16449, MKT 1606 Name :TANKNOLOGY INC. Address :3720 EAST 7000 SOUTH State ID 4000998 SALT LAKE CITY, UT 84121 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :801-942-6668 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :6 Products per Nozzle :3 Tanks Manifolded ?No Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) TNK4 REGULAR RUL 19782 14446 5336 13:22 2.00 2.00 2.00 1.99 1.99 1.98 1.83 Pass TNK6 PREMIUM PUL 7901 2760 5141 13:30 2.00 2.00 1.99 1.99 1.98 1.98 1.82 Pass Total 27683 17206 10477 All Comments: Tester :David Mathie Test Date :8/21/2024 Signature :Work Order :2370466 WO: 2370466 PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 1.91 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -2.17 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.62 Pass Neg Leak Rate (CFH)0.21 16 0.0339 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.96 Pass PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 1.77 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -1.98 Fail PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.69 Pass Neg Leak Rate (CFH)0.21 14 0.0297 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.05 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0233 Total -ve LR: 0.0636 Test Date 8/21/2024 Technician Name David Mathie WO #2370466 Facility Name / Loc #7-ELEVEN 16449, MKT 1606 16449 Street 3720 EAST 7000 SOUTH State ID 4000998 City, St, Zip SALT LAKE CITY, UT 84121 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2370466 Site ID / Name:16449 / 7-ELEVEN 16449, MKT 1606 Address:3720 EAST 7000 SOUTH State ID 4000998 City:SALT LAKE CITY State:UT Zip:84121 W.O.# NW1-2370466 +AAE-i101002408211412021105030304+ACYAJg-FA0C+AAMAAQ- I10101 AUG 21, 2024 2:12 PM 176936 7-11 16449 3720 FORT UNION BLVD SLC UT 84121 90558298205001 SYSTEM STATUS REPORT T 5:DELIVERY NEEDED L 4:FUEL ALARM +AAMAAQ- I90200 AUG 21, 2024 2:12 PM SOFTWARE REVISION LEVEL VERSION 333.04 SOFTWARE+ACM- 346333-100-E CREATED - 13.06.07.08.25 S-MODULE+ACM- 330160-102-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR +AAMAAQ- I11B00 AUG 21, 2024 2:12 PM 176936 7-11 16449 3720 FORT UNION BLVD SLC UT 84121 90558298205001 SERVICE NOTICE SESSION REPORT START TIME END TIME AUG 21, 2024 12:33 PM AUG 21, 2024 2:09 PM AUG 24, 2023 9:08 AM AUG 24, 2023 12:24 PM SEP 7, 2022 8:39 AM SEP 7, 2022 10:22 AM NOV 19, 2021 11:58 AM NOV 19, 2021 12:17 PM SEP 23, 2020 8:52 AM SEP 23, 2020 12:24 PM SEP 26, 2019 8:57 AM SEP 26, 2019 10:06 AM +AAMAAQ- I20100 AUG 21, 2024 2:12 PM 176936 7-11 16449 3720 FORT UNION BLVD SLC UT 84121 90558298205001 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 4 RUL 14433 14260 5349 80.50 0.00 77.38 5 DSL 1722 1711 10182 25.26 0.00 74.40 6 PUL 2760 2727 5141 44.90 0.00 77.06 +AAMAAQ- I30100 AUG 21, 2024 2:12 PM 176936 7-11 16449 3720 FORT UNION BLVD SLC UT 84121 90558298205001 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 RUL INTERSTITIAL SENSOR NORMAL 2 PUL-DSL INTERSTITIAL SENSOR NORMAL 3 RUL STP SUMP SENSOR NORMAL 4 RUL FILL SUMP FUEL ALARM 5 PUL STP SUMP SENSOR NORMAL 6 PUL FILL SUMP SENSOR NORMAL 7 DSL STP SUMP SENSOR NORMAL 9 DISPENSER PAN 1-2 SENSOR NORMAL 10 DISPENSER PAN 3-4 SENSOR NORMAL 11 DISPENSER PAN 5-6 SENSOR NORMAL 12 DSL FILL SENSOR NORMAL +AAMAAQ- I30200 AUG 21, 2024 2:12 PM 176936 7-11 16449 3720 FORT UNION BLVD SLC UT 84121 90558298205001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 RUL INTERSTITIAL AUG 24, 2023 10:01 AM FUEL ALARM SEP 7, 2022 8:59 AM FUEL ALARM NOV 19, 2021 12:02 PM FUEL ALARM 2 PUL-DSL INTERSTITIAL AUG 21, 2024 1:36 PM FUEL ALARM AUG 24, 2023 10:03 AM FUEL ALARM SEP 7, 2022 8:49 AM FUEL ALARM 3 RUL STP SUMP AUG 21, 2024 1:17 PM FUEL ALARM AUG 24, 2023 9:29 AM FUEL ALARM SEP 7, 2022 9:07 AM FUEL ALARM 4 RUL FILL SUMP AUG 21, 2024 1:00 PM FUEL ALARM AUG 20, 2024 12:08 PM FUEL ALARM MAY 6, 2024 11:00 AM FUEL ALARM 5 PUL STP SUMP AUG 21, 2024 1:18 PM FUEL ALARM AUG 24, 2023 10:44 AM FUEL ALARM AUG 24, 2023 9:40 AM FUEL ALARM 6 PUL FILL SUMP AUG 21, 2024 1:05 PM FUEL ALARM AUG 24, 2023 10:25 AM FUEL ALARM SEP 7, 2022 9:21 AM FUEL ALARM 7 DSL STP SUMP AUG 21, 2024 1:18 PM FUEL ALARM AUG 24, 2023 9:45 AM FUEL ALARM DEC 13, 2022 11:29 AM FUEL ALARM 9 DISPENSER PAN 1-2 AUG 21, 2024 1:23 PM FUEL ALARM MAY 19, 2024 12:28 PM FUEL ALARM AUG 24, 2023 9:18 AM FUEL ALARM 10 DISPENSER PAN 3-4 AUG 21, 2024 1:23 PM FUEL ALARM AUG 24, 2023 9:18 AM FUEL ALARM SEP 7, 2022 10:08 AM FUEL ALARM 11 DISPENSER PAN 5-6 AUG 21, 2024 1:24 PM FUEL ALARM AUG 24, 2023 9:18 AM FUEL ALARM SEP 7, 2022 10:09 AM FUEL ALARM 12 DSL FILL AUG 21, 2024 1:12 PM FUEL ALARM AUG 24, 2023 10:18 AM FUEL ALARM APR 3, 2023 4:15 AM FUEL ALARM +AAMAAQ- IA0100 AUG 21, 2024 2:13 PM TYPE CODE LENGTH SERIAL NO. D/CODE TANK 4 RUL MAG D004 126.00 669483 2324 TANK 5 DSL MAG D004 120.00 546610 3904 TANK 6 PUL MAG D004 120.00 535813 3104 +AAMAAQ- 934 TANK 4 SETUP CONDITIONS PRODUCT: RUL PRODUCT CODE 4 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 17803 HIGH PRODUCT LIMIT: 18793 LOW PRODUCT: 747 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000690 DELIVERY DELAY: 5 TANK FULL CAPACITY: 19782 19443 18825 18025 17087 3/4 HEIGHT CAPACITY: 16039 14906 13705 12457 11178 1/2 HEIGHT CAPACITY: 9883 8588 7310 6064 4866 1/4 HEIGHT CAPACITY: 3735 2690 1756 960 345 TANK DIAMETER: 118.37 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 935 TANK 5 SETUP CONDITIONS PRODUCT: DSL PRODUCT CODE 5 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 10713 HIGH PRODUCT LIMIT: 11308 LOW PRODUCT: 416 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000450 DELIVERY DELAY: 5 TANK FULL CAPACITY: 11904 0 0 0 0 3/4 HEIGHT CAPACITY: 9710 0 0 0 0 1/2 HEIGHT CAPACITY: 5944 0 0 0 0 1/4 HEIGHT CAPACITY: 2186 0 0 0 0 TANK DIAMETER: 118.37 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 936 TANK 6 SETUP CONDITIONS PRODUCT: PUL PRODUCT CODE 6 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 7110 HIGH PRODUCT LIMIT: 7506 LOW PRODUCT: 332 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000690 DELIVERY DELAY: 5 TANK FULL CAPACITY: 7901 0 0 0 0 3/4 HEIGHT CAPACITY: 6360 0 0 0 0 1/2 HEIGHT CAPACITY: 3960 0 0 0 0 1/4 HEIGHT CAPACITY: 1558 0 0 0 0 TANK DIAMETER: 118.37 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- I61100 AUG 21, 2024 2:13 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK NOV 6, 2012 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED +AAMAAQ- I70300 AUG 21, 2024 2:13 PM LIQUID TYPE SENSOR LOCATION TYPE 1 RUL INTERSTITIAL TRI-STATE (SINGLE FLOAT) 2 PUL-DSL INTERSTITIAL TRI-STATE (SINGLE FLOAT) 3 RUL STP SUMP TRI-STATE (SINGLE FLOAT) 4 RUL FILL SUMP TRI-STATE (SINGLE FLOAT) 5 PUL STP SUMP TRI-STATE (SINGLE FLOAT) 6 PUL FILL SUMP TRI-STATE (SINGLE FLOAT) 7 DSL STP SUMP TRI-STATE (SINGLE FLOAT) 8 DSL FILL SUMP TRI-STATE (SINGLE FLOAT) 9 DISPENSER PAN 1-2 TRI-STATE (SINGLE FLOAT) 10 DISPENSER PAN 3-4 TRI-STATE (SINGLE FLOAT) 11 DISPENSER PAN 5-6 TRI-STATE (SINGLE FLOAT) 12 DSL FILL TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) +AAMAAQ- I80800 AUG 21, 2024 2:13 PM +AAMAAQ-9999FF1B+AAMAAQ- I10200 AUG 21, 2024 2:13 PM 176936 7-11 16449 3720 FORT UNION BLVD SLC UT 84121 90558298205001 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163830 162735 2 4 PROBE / G.T. 163159 162687 3 INTERSTITIAL BD 200836 200173 4 INTERSTITIAL BD 200953 200245 5 UNUSED 9359836 9051271 6 UNUSED 9340073 9043665 7 UNUSED 9339894 9041678 8 UNUSED 9334468 9038938 9 UNUSED 9335847 9044002 10 UNUSED 9332967 9040074 11 UNUSED 9336048 9036579 12 UNUSED 9329104 9042837 13 UNUSED 9327139 9041170 14 UNUSED 9332007 9033724 15 UNUSED 9335334 9027398 16 UNUSED 9329081 9039526 COMM 1 UNUSED 100423 9039777 COMM 2 ELEC DISP INT. 100834 100533 COMM 3 SERIAL SAT BD 481012 479502 COMM 4 UNUSED 9336428 9045533 COMM 5 RS485 SERIAL BD 68705 68608 COMM 6 MT COMM BOARD 408736 407943 +AAM-