HomeMy WebLinkAboutDERR-2024-010209PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 8/21/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 7/30/2024 Order Number: 2374364 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: Jackson Foods #154 4607 W. 6200 S. West Jordan, UT 84008 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :Jackson Foods #154 Name :TANKNOLOGY INC. Address :4607 W. 6200 S. West Jordan, UT 84008 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :-Phone :(800) 800-4633 Stage I System?DUAL Stage II System?STUB UP Total # of Nozzles :12 Products per Nozzle :3 Tanks Manifolded ?Yes Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) 1 REG UNLEAD 19951 13790 6161 2 PREMIUM 15104 6873 8231 11:18 2.00 1.60 1.93 Fail Total 35055 20663 14392 All 11:18 2.00 1.60 1.93 Fail Comments: test balls in atg riser fill caps on Tester :David Mathie Test Date :7/30/2024 Signature :Work Order :2374364 WO: 2374364 PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 1.71 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -2.30 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.56 Pass Neg Leak Rate (CFH)0.21 13 0.0276 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.21 Pass PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 0.04 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -0.11 Fail PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 4 0.0085 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.87 Pass Neg Leak Rate (CFH)0.21 12 0.0254 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.05 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0212 Total -ve LR: 0.0530 Test Date 7/30/2024 Technician Name David Mathie WO #2374364 Facility Name / Loc #Jackson Foods #154 154 Street 4607 W. 6200 S. City, St, Zip West Jordan, UT 84008 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2374364 Site ID / Name:154 / Jackson Foods #154 Address:4607 W. 6200 S. City:West Jordan State:UT Zip:84008