HomeMy WebLinkAboutDERR-2024-010145Facility Information Facility Name:SUNRISE CHEVRON Release ID:FCO Facility Address:432 W MAIN ST DUCHESNE, UT 84021 Facility ID:9000053 Notification Date:08/19/1991 Owner Name:MUNDY LLC Reporting Party:BOB ADAMSON Owner Address:PO BOX 269 DUCHESNE, UT 84021 Project Manager:Mark Crim Site Assessment Information a. Contaminant Source Information Cause of Release (if known) Product Released Amount Released (gal) Size (gal) # of USTs Tank Piping Disp Over/Spill Other Comments Gasoline UNK 2-2K Yes Yes Diesel UNK 1-6K Yes Yes Waste Oil Unknown Other Tank Piping Disp Free Prod Cont Soil Sources Removed:Yes Yes Yes No No b. Land Use Information Current Land use at the Site:Commercial Surrounding Neighborhood:Commercial (Note: Surrounding land use is Residential if one or more residences share a common property line with the Facility) c. Soil Information Soil Type(s) Depth to Contaminated Soil (feet below land surface): 5-10 SC-Clayey sands Method of Soil Type Identification:Unified Soil Classification d. Groundwater Information Was groundwater encountered?:Yes Thickness of Free Product:Historic Depth to groundwater (feet below land surface): 6-7 Is groundwater impacted at any concentration: Yes Groundwater flow direction:SE Measured Slope direction of surface topography:SE e. Distance from Highest Measured Contaminated Concentrations and Sampling Location to Nearest Potential Receptor Receptors:(Enter distance to each receptor from corresponding sampling location in feet) Distance- Location Distance- Location Water Line:5 - SS-W @5-7'Sewer Line:5 - SS-W @5-7'Building Desc:Other Electrical:UNK - Natural Gas:>30 - SS-WSW @5- 7' Other Desc:Currently barren land. Building:>30 - SS-WSW @5- 7' Telephone:UNK - Property Line 0 - CS-B22 Storm Drain:NA - Other(specify): - Receptors Within 500 feet: Municipal Well:>500 Domestic Well:>500 Irrigation Well:>500 Other: Surface Water(specify type: lake, stream, creek, river, wetland):Dist: >500 Desc: Strawberry River Utah's RBCA Tier 1 Worksheet Printed on: 8/21/2024 10:31:20 AM Facility History - Executive Summary Release FCO: August 1991, three USTs removed. Petroleum saturated soils noted and product float on GW. Also 3-ASTs were adjacent to the USTs. Both AST and UST product lines abandoned with install of new PST-covered USTs approx. 1981. PST-Funded USTs and Release ID JRH cleaned up and obtained NFA (7-2016). Some soil excavation work occurred in 2000 with confirmation samples > Tier 1. More work needed to evaluate current conditions, as historic work shows UST and AST source areas > Tier 1 levels for soil and groundwater. Last sampling data was 2011 for soil and 2014 for GW. RBCA Tier 1 Screening Level Evaluation Groundwater(mg/L)Soil(mg/Kg) Constituent ISL/Tier 1 Level Highest Concentration and Sampling Location ISL/Tier 1 Level Highest Concentration and Sampling Location Benzene 0.005/0.30 0.14 MW-1A 0.20/0.90 55 SS-W @5-7' Toluene 1.0/3.00 0.013 MW-1A 9.0/25.0 497 SS-WSW @5-7' Ethylbenzene 0.7/4.00 0.061 MW-1A 5.0/23.0 166 SS-WSW @5-7' Xylenes 10.0/10.0 0.366 MW-1A 142.0/142.0 1,080 SS-WSW @5-7' Napthalene 0.70/0.70 <0.005 MW-12 51.0/51.0 92.1 SS-WSW @5-7' MTBE 0.20/0.20 <0.02 MW-12 0.30/0.30 <2.2 B-14 @5-7' TPH-gasoline 1.0/10.0 86 MW-12 150/1500 10,300 SS-WSW @5-7' TPH-diesel 1.0/10.0 732 MW-12 500/5000 8,950 SS-W @5-7' Oil and Grease/TRPH 10.0/10.0 NT NT 1000/10000 NT NT Recommended Tier 1 Actions All contaminant concentration levels are below ISLs or below Tier 1 screening levels and no receptors are within the critical distances. Recommendation - No further action. Tier 1 criteria (contaminant concentration and/or distance to receptors) are exceeded at the site. Recommendation - See attached supplemental information worksheet. Evaluation Completed by:Date: DERR Project Manager's Signature Utah's RBCA Tier 1 Worksheet Printed on: 8/21/2024 10:31:20 AM 8-21-2024