Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2024-010100
IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION OVERFILL OPERABILITY PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 8/19/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 8/14/2024 Order Number: 2370465 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN 41620 5600 South Van Winkle Expy State ID 4002590 Murray, UT 84121 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 7-ELEVEN 41620 5600 South Van Winkle Expy State ID 4002590 Murray UT 84121 41620 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 08/14/2024 RUL PUL Vaporless LD- 2000 Vaporless LD- 2000 Vaporless LD- 2000 30 30 200 3 20 4 30 30 200 3 20 4 30 30 200 2 20 3 UT151 David Mathie NW1-2370465 Low Sulfur Diesel T1:1 T2:1 T3:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2370465 Date:8/14/2024 Site Name/ID:7-ELEVEN 41620 Address:5600 South Van Winkle Expy State ID 4002590 City:Murray State:UT Zip:84121 How Inspected: Line Test NFPA 30A PEI RP1200 Other STP PRESSURE Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 40 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 40 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN 41620 7-ELEVEN, INC. 5600 South Van Winkle Expy State ID 4002590 Murray UT 84121 4002590 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 08/14/2024 1 2 3 RUL PUL DSL VR350 VR350 VR350 19782 7901 11904 118.33 118.33 118.33 UT151 David Mathie 5600 South Van Winkle Expy State ID 4002590 7-ELEVEN 41620 5600 South Van Winkle Expy State ID 4002590, Murray, UT 84121 41620 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 08/14/2024 ANNULAR ANNULAR SB FILL STP SB FILL STP SB FILL RUL PUL/DSL RUL RUL PUL PUL DSL UT151 David Mathie 5600 South Van Winkle Expy State ID 4002590 7-ELEVEN 41620 5600 South Van Winkle Expy State ID 4002590, Murray, UT 84121 41620 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 08/14/2024 STP UDC UDC UDC UDC UDC UDC DSL 1/2 3/4 5/6 7/8 9/10 11/12 UT151 David Mathie 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-ELEVEN 41620 Name :TANKNOLOGY INC. Address :5600 South Van Winkle Expy State ID 4002590 Murray, UT 84121 Address : 11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :385-395-9832 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :12 Products per Nozzle :3 Tanks Manifolded ?No Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) 1 RUL 19782 13962 5820 10:46 2.00 2.00 2.00 2.00 2.00 1.99 1.84 Pass 2 PUL 7901 2007 5894 10:54 2.00 2.00 2.00 2.00 2.00 2.00 1.84 Pass Total 27683 15969 11714 All Comments: Tester :David Mathie Test Date :8/14/2024 Signature :Work Order :2370465 WO: 2370465 PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 20 0.0424 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.18 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -3.84 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 4 0.0085 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.62 Pass Neg Leak Rate (CFH)0.21 15 0.0318 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.98 Pass PVVC tested ==>PUL CENTER Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 20 0.0424 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.21 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -3.92 Fail PVVC tested ==>PUL CENTER Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.56 Pass Neg Leak Rate (CFH)0.21 14 0.0297 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.02 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0191 Total -ve LR: 0.0615 Test Date 8/14/2024 Technician Name David Mathie WO #2370465 Facility Name / Loc #7-ELEVEN 41620 41620 Street 5600 South Van Winkle Expy State ID 4002590 City, St, Zip Murray, UT 84121 Pressure Vacuum Vent Cap Test Form TP-201.1E 7-ELEVEN 41620 5600 South Van Winkle Expy State ID 4002590 Murray, UT 84121 41620 Tanknology, Inc. 7-ELEVEN, INC. 972-828-7575 800-800-4633 08/14/2024 RUL 1 19782 118.375 OPW PUL 2 7901 118.375 OPW DSL 3 11903 118.375 OPW UT151 David Mathie P.O. BOX 711 DALLAS, TX 75221 Overfill Prevention Equipment Inspection OPW 61 and 71 Series Overfill Prevention Device Inspection Date:8/14/2024 Customer Name:7-ELEVEN, INC. Location #:7-ELEVEN 41620 Location Address:5600 South Van Winkle Expy State ID 4002590 ,Murray ,UT , 84121 OPW Model Number:71S0 PART 1) Proper height setting calculation Maximum Tank Volume per: Tank Chart A gallons Max shut off requirement for Flapper is 95% B 95% Multiply Maximum tank volume by 95% C gallons Use tank chart to determine height of calculated volume D inches Measure top of fill riser threads, or face seal adapter when used, to tank top E inches Tank diameter From Chart F inches Upper Tube in tank (G) F - D = G G inches Subtract 2 inches from upper tube in tank G - 2"= H H inches Calculated minimum upper tube length (I) H + E = I I inches Actual measured upper tube length (Without fill adapter) (J) J inches PART 2) Device certification criteria evaluation Criteria 1 Does the overfill prevention device meet the 95% requirement? Criteria 1a If the final shutoff volume is installed greater than 95%, is there at least 250 gallons of ullage above the overfill device activation point to ensure that none of the tank top fittings are exposed to product, meeting the criteria established in EPA 280.20iic and per OPW installation guidelines. Criteria 2 Is the Actual measured upper tube length 6.5 inches or more than the fill riser? (J must be 6.5" or more than E) Criteria 3 Does the overfill prevention device function as required? (Inspect the device for damage, contamination, freedom of movement, weakening due to wear and corrosion) PART 3) Device Certification PASS / FAIL Technician certifies that the device is operationally compliant. 1 19782.000 0.95 18792.900 106.375 59.250 118.375 12.000 10.000 69.250 72.625 Yes NA Yes Yes Pass 2 7901.000 0.95 7505.950 106.875 58.500 118.375 11.500 9.500 68.000 71.625 Yes NA Yes Yes Pass 3 11904.000 0.95 11308.800 105.875 51.500 118.375 12.500 10.500 62.000 65.250 Yes NA Yes Yes Pass 0.95 Comments: Signature of Technician: Date: 8/14/2024 David Mathie WO: NW1- 2370465 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2370465 Site ID / Name:41620 / 7-ELEVEN 41620 Address:5600 South Van Winkle Expy State ID 4002590 City:Murray State:UT Zip:84121 W.O.# NW1-2370465 +AAE- I10100 AUG 14, 2024 11:40 AM 873931 7-11 41620 5584 S VAN WINKLE EX MURRAY UT 84117 W04277766705001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I90200 AUG 14, 2024 11:41 AM SOFTWARE REVISION LEVEL VERSION 336.01 SOFTWARE+ACM- 346336-100-B CREATED - 20.04.26.20.30 S-MODULE+ACM- 330160-100-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR +AAMAAQ- I11B00 AUG 14, 2024 11:41 AM 873931 7-11 41620 5584 S VAN WINKLE EX MURRAY UT 84117 W04277766705001 SERVICE NOTICE SESSION REPORT START TIME END TIME AUG 14, 2024 9:06 AM AUG 14, 2024 11:37 AM MAY 10, 2024 8:26 AM MAY 10, 2024 11:26 AM AUG 15, 2023 9:04 AM AUG 15, 2023 10:42 AM AUG 16, 2022 10:33 AM AUG 16, 2022 12:05 PM AUG 26, 2021 8:20 AM AUG 26, 2021 1:53 PM +AAMAAQ- I20100 AUG 14, 2024 11:41 AM 873931 7-11 41620 5584 S VAN WINKLE EX MURRAY UT 84117 W04277766705001 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 REGULAR 13880 13696 5902 77.66 0.00 79.19 2 PREMIUM 1957 1934 5944 34.94 0.00 76.76 3 DIESEL 3877 3843 8027 43.69 0.63 79.52 +AAMAAQ- I30100 AUG 14, 2024 11:41 AM 873931 7-11 41620 5584 S VAN WINKLE EX MURRAY UT 84117 W04277766705001 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 RUL ANNULAR SENSOR NORMAL 2 PUL-DSL ANNULAR SENSOR NORMAL 3 RUL SPILL BKT SENSOR NORMAL 4 RUL STP SENSOR NORMAL 5 PUL SPILL BKT SENSOR NORMAL 6 PUL STP SENSOR NORMAL 7 DSL SPILL BKT SENSOR NORMAL 8 DSL STP SENSOR NORMAL 9 DISP 1-2 SENSOR NORMAL 10 DISP 3-4 SENSOR NORMAL 11 DISP 5-6 SENSOR NORMAL 12 DISP 7-8 SENSOR NORMAL 13 DISP 9-10 SENSOR NORMAL 14 DISP 11-12 SENSOR NORMAL +AAMAAQ- I30200 AUG 14, 2024 11:41 AM 873931 7-11 41620 5584 S VAN WINKLE EX MURRAY UT 84117 W04277766705001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 RUL ANNULAR AUG 14, 2024 10:44 AM FUEL ALARM AUG 15, 2023 9:53 AM FUEL ALARM AUG 16, 2022 11:59 AM FUEL ALARM 2 PUL-DSL ANNULAR AUG 14, 2024 10:49 AM FUEL ALARM AUG 15, 2023 10:13 AM FUEL ALARM AUG 16, 2022 12:01 PM FUEL ALARM 3 RUL SPILL BKT AUG 14, 2024 9:20 AM FUEL ALARM AUG 15, 2023 9:55 AM FUEL ALARM AUG 16, 2022 11:45 AM FUEL ALARM 4 RUL STP AUG 14, 2024 10:12 AM FUEL ALARM AUG 15, 2023 9:58 AM FUEL ALARM AUG 16, 2022 11:17 AM FUEL ALARM 5 PUL SPILL BKT AUG 14, 2024 9:32 AM FUEL ALARM AUG 15, 2023 10:01 AM FUEL ALARM AUG 16, 2022 11:51 AM FUEL ALARM 6 PUL STP AUG 14, 2024 10:13 AM FUEL ALARM AUG 15, 2023 10:03 AM FUEL ALARM AUG 16, 2022 11:18 AM FUEL ALARM 7 DSL SPILL BKT AUG 14, 2024 9:45 AM FUEL ALARM AUG 15, 2023 10:07 AM FUEL ALARM AUG 16, 2022 11:54 AM FUEL ALARM 8 DSL STP AUG 14, 2024 10:14 AM FUEL ALARM AUG 15, 2023 10:07 AM FUEL ALARM AUG 16, 2022 11:21 AM FUEL ALARM 9 DISP 1-2 AUG 14, 2024 10:00 AM FUEL ALARM AUG 15, 2023 9:07 AM FUEL ALARM AUG 16, 2022 10:57 AM FUEL ALARM 10 DISP 3-4 AUG 14, 2024 10:01 AM FUEL ALARM AUG 15, 2023 9:08 AM FUEL ALARM AUG 16, 2022 10:58 AM FUEL ALARM 11 DISP 5-6 AUG 14, 2024 10:01 AM FUEL ALARM AUG 15, 2023 9:09 AM FUEL ALARM AUG 16, 2022 10:58 AM FUEL ALARM 12 DISP 7-8 AUG 14, 2024 10:01 AM FUEL ALARM AUG 15, 2023 9:10 AM FUEL ALARM AUG 16, 2022 10:58 AM FUEL ALARM 13 DISP 9-10 AUG 14, 2024 10:02 AM FUEL ALARM AUG 15, 2023 9:12 AM FUEL ALARM AUG 16, 2022 10:58 AM FUEL ALARM 14 DISP 11-12 AUG 14, 2024 10:02 AM FUEL ALARM AUG 15, 2023 9:12 AM FUEL ALARM AUG 16, 2022 10:59 AM FUEL ALARM +AAMAAQ- IA0100 AUG 14, 2024 11:41 AM TYPE CODE LENGTH SERIAL NO. D/CODE TANK 1 REGULAR MAG D004 126.00 401381 3804 TANK 2 PREMIUM MAG D004 126.00 362656 1404 TANK 3 DIESEL MAG D004 126.00 410603 4304 +AAMAAQ- 931 TANK 1 SETUP CONDITIONS PRODUCT: REGULAR PRODUCT CODE 1 HIGH WATER LIMIT 1.0 OVERFILL LIMIT: 17803 HIGH PRODUCT LIMIT: 18792 LOW PRODUCT: 1504 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 25 THERMAL COEFF: 0.000690 DELIVERY DELAY: 5 TANK FULL CAPACITY: 19782 0 0 0 0 3/4 HEIGHT CAPACITY: 16055 0 0 0 0 1/2 HEIGHT CAPACITY: 9897 0 0 0 0 1/4 HEIGHT CAPACITY: 3718 0 0 0 0 TANK DIAMETER: 118.33 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 932 TANK 2 SETUP CONDITIONS PRODUCT: PREMIUM PRODUCT CODE 2 HIGH WATER LIMIT 1.0 OVERFILL LIMIT: 7110 HIGH PRODUCT LIMIT: 7505 LOW PRODUCT: 651 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 25 THERMAL COEFF: 0.000690 DELIVERY DELAY: 5 TANK FULL CAPACITY: 7901 0 0 0 0 3/4 HEIGHT CAPACITY: 6365 0 0 0 0 1/2 HEIGHT CAPACITY: 3964 0 0 0 0 1/4 HEIGHT CAPACITY: 1551 0 0 0 0 TANK DIAMETER: 118.33 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 933 TANK 3 SETUP CONDITIONS PRODUCT: DIESEL PRODUCT CODE 3 HIGH WATER LIMIT 1.0 OVERFILL LIMIT: 10713 HIGH PRODUCT LIMIT: 11308 LOW PRODUCT: 1024 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 25 THERMAL COEFF: 0.000450 DELIVERY DELAY: 5 TANK FULL CAPACITY: 11904 0 0 0 0 3/4 HEIGHT CAPACITY: 9710 0 0 0 0 1/2 HEIGHT CAPACITY: 5944 0 0 0 0 1/4 HEIGHT CAPACITY: 2172 0 0 0 0 TANK DIAMETER: 118.33 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- I61100 AUG 14, 2024 11:41 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK APR 26, 2020 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED +AAMAAQ- I70300 AUG 14, 2024 11:41 AM LIQUID TYPE SENSOR LOCATION TYPE 1 RUL ANNULAR TRI-STATE (SINGLE FLOAT) 2 PUL-DSL ANNULAR TRI-STATE (SINGLE FLOAT) 3 RUL SPILL BKT NORMALLY CLOSED 4 RUL STP TRI-STATE (SINGLE FLOAT) 5 PUL SPILL BKT NORMALLY CLOSED 6 PUL STP TRI-STATE (SINGLE FLOAT) 7 DSL SPILL BKT NORMALLY CLOSED 8 DSL STP TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 DISP 9-10 TRI-STATE (SINGLE FLOAT) 14 DISP 11-12 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) +AAMAAQ- I80800 AUG 14, 2024 11:41 AM RELAY SETUP REPORT R 1: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 2: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 3: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 4: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - +AAMAAQ- I10200 AUG 14, 2024 11:41 AM 873931 7-11 41620 5584 S VAN WINKLE EX MURRAY UT 84117 W04277766705001 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163541 161816 2 INTERSTITIAL BD 200540 199716 3 INTERSTITIAL BD 200562 200056 4 UNUSED 9720668 9534203 5 UNUSED 9668114 9520347 6 UNUSED 9662467 9522688 7 UNUSED 9654050 9523990 8 UNUSED 9652929 9520585 9 RELAY BOARD 14993 14992 10 UNUSED 9657779 9525380 11 UNUSED 9647691 9523429 12 UNUSED 9642298 9521585 13 UNUSED 9647183 9520501 14 UNUSED 9642636 9521976 15 UNUSED 9639633 9522431 16 UNUSED 9639654 9522193 COMM 1 ELEC DISP INT. 100364 100367 COMM 2 UNUSED 9648854 9522474 COMM 3 SERIAL SAT BD 477862 477609 COMM 4 UNUSED 9644180 9524426 COMM 5 RS485 SERIAL BD 68236 68256 COMM 6 MT COMM BOARD 408436 408623 +AAM-