HomeMy WebLinkAboutDRC-2024-0060481 of Page 3
U:\RAD\COMMON\Uranium mills\UT0900480 Anfield Res - Shootaring Cyn UMill\HP Inspection Modules\2024\RADMOD-Shootaring
Inspection Report 6-12-2024.docx
INSPECTION REPORT
Inspection Module: RADMOD-Shootaring POSTINGS/EXTERNAL MONITORING
Inspection Location: Anfield Resources Holding Corp. (Anfield), Shootaring Canyon Mill,
Garfield County, Utah
Inspection Items: Radiological Posting, Notice to Workers Postings, External Monitoring,
Radiation Safety Training and Dosimetry
Inspection Date: June 12, 2024
Inspector: Ryan Johnson, Utah Division of Waste Management and Radiation
Control (DWMRC)
Personnel Contacted: LaMiya Morrill, Site Supervisor
DWMRC Meters
Used
Model Serial Number Calibration Due
Date
Dose Rate Bicron 9048 9/18/2024
Note: Instruments were source checked prior to inspection.
Governing Documents:
Radioactive Materials License UT0900480
UAC R313-15
UAC R313-18
UAC R313-24
Opening Meeting
Anfield Personnel
LaMiya Morrill, Site Supervisor
DWMRC Personnel
Ryan Johnson, DWMRC Inspector
The inspector briefly discussed the purpose of the inspection with Anfield’s Site Supervisor.
The inspector discussed with them that the inspection would be a tour of the Mill and a review of
records.
Inspection Summary
The inspection consisted of a tour of the Shootaring Canyon Mill facilities and reviewing
applicable documents. Due to the inactive status of Shootaring Canyon Mill, no work activity
was observed within the Mills restricted area.
2 of Page 3
U:\RAD\COMMON\Uranium mills\UT0900480 Anfield Res - Shootaring Cyn UMill\HP Inspection Modules\2024\RADMOD-Shootaring
Inspection Report 6-12-2024.docx
Inspection Item
Mill Tour:Anfield staff took the inspector on a tour of the Shootaring Canyon Mill’s facilities.
The inspector observed:
The entrance to the Mill and the gates to the Mills restricted area were properly posted.
Postings around the Mill were legible and in good condition;
The required Notice to Workers documentation (as required by UAC R313-18) on the
wall in the break room of the facilities office building;
All of Anfield’s personnel wore proper dosimetry within the restricted area of the Mill
and their dosimetry was kept in the Mill’s office building when not being used;
Proper radiological instrumentation was being used, maintained and calibrated;
Personnel surveyed themselves before leaving the restricted area.
Perimeter fencing and gates were in good condition;
Known and suspected contaminated areas within the restricted area. Discussions of
these areas were about what needed to surveyed, cleaned up and documented prior to any
work being done within the restricted area;
Ore on the ore pad was covered with soil;
Radiological general area dose rate measurements taken by the inspector during the
inspection and are as follows:
o 8-20 µrem/hr inside the restricted area;
The following documents were reviewed by the Inspector:
The Radiological training records for the Mill’s Supervisor and Staff and found them to
be complete, legible and appropriate; and
The facility’s ALARA Report and determined it met the requirements of the License.
Deficiencies:
None
Other:
During the records review, the Licensee provided a written memo documenting minor self-
reportable items. They are as follows:
1. The RSO had the tape under the leach tanks changed from saying “Radiation Area” to a
caution tape with small signs attached that said “Any Area within this area may Contain
Radioactive Material”.
2. A survey meter was used past its calibration due date for about one month. When it was
discovered, the Licensee replaced the meter with a calibrated meter and the out-of-date
meter was sent in for calibration.
The inspector determined that the 1st item is not a compliance issue because the caution tape was
placed there to discourage people from walking around the leach tanks and through the sandy
material that is under them.
The 2nd item is a minor compliance issue and would be a severity level IV. The inspector
determined that the Licensee acted appropriately and the corrective actions in the written
document will be sufficient. This item will be followed up in future inspections.
3 of Page 3
U:\RAD\COMMON\Uranium mills\UT0900480 Anfield Res - Shootaring Cyn UMill\HP Inspection Modules\2024\RADMOD-Shootaring
Inspection Report 6-12-2024.docx
The written memo provided to the Inspector meets the requirements of R313-14-15(1)(c). The
memo can be reviewed by request at the Mill facility.
Closeout Meeting
Anfield Personnel
LaMiya Morrill, Site Supervisor
DWMRC Personnel
Ryan Johnson, DWMRC Inspector
Findings
Compliant
Recommendations
None
Prepared By: Ryan Johnson 6/24/2024
(Print Name) (Signature) (Date)
Reviewed
By: Heather Mickelson 6/24/2024
(Print Name) (Signature) (Date)
Reviewed
By: Adam Wingate 6//2024
(Print Name) (Signature) (Date)