Loading...
HomeMy WebLinkAboutDDW-2024-009973 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144830 • Salt Lake City, UT 84114-4830 Telephone (801) 536-4200 • Fax (801) 536-4211 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF DRINKING WATER Nathan Lunstad Director June 3, 2024 Andy Crnich Woodland Mutual Water 3651 S 1000 E Woodland, UT 84036 Dear Andy Crnich: Subject: Corrective Action Plan Closure UTAH22018-2024-01 On August 24, 2022, Woodland Mutual Water and the Division of Drinking Water entered into a Corrective Action Plan (CAP). As of June 03, 2024, Woodland Mutual Water has successfully completed the requirements listed in the CAP. The CAP is now officially closed, and the water system’s rating will remain at an approved status with 120 Improvement Priority System (IPS) points. The Division of Drinking Water recognizes that addressing deficiencies and violations can be difficult and often requires significant financial and personnel resources. We would like to thank Woodland Mutual Water for the efforts put forth in resolving the items, for your continued commitment to maintaining reliable infrastructure, and for ensuring the safety of the drinking water provided to your customers. Please find enclosed current copies of the completed CAP requirements, monitoring schedule, and IPS report to help Woodland Mutual Water maintain compliance and an approved status. If you have any questions, please contact Brandi Smith at (385) 515-1650 or brandismith@utah.gov. If there is ever anything we can do to support you in your role of protecting public health, please contact us. Sincerely, Helen Lau Compliance and Operator Assistance Section Manager Division of Drinking Water Enclosure ' ) 0 — 0 ) B v A ? A C @ F w ? D ˜ State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF DRINKING WATER Nathan Lunstad Director Completed CAP Requirements Deficiency/Violation Date of Occurrence Plan to return to compliance Date of Completion IPS Points Resolved V009-ST001-Storage tank lacks a function gasket 08/2022 Ensure system has a functioning gasket 08/23/2023 25 V011-ST001-End of storage tank overflow lacks a 12 inch clearance 08/2022 Ensure that the system has a 12 inch clearance on tank overflow 08/23/2023 25 V012-ST001-End of storage tank overflow pipe lacks a No.4 screen 08/2022 Ensure that the overflow has a No. 4 screen 08/23/2023 25 V022-ST001- Storage tank roof or sidewalls show signs of serve deterioration 08/2022 Repair/replace storage tank as required 06/03/2024 50 G001-ST003- Unapproved facility in service 08/2022 Get proper approval and permits from the Division 05/22/2024 50 S029-WS002-End of air release vacuum relief valve piping lacks a No.14 Screen 08/2022 Ensure that the air release vacuum relief valve has a No. 14 Screen 08/23/2023 25