Loading...
HomeMy WebLinkAboutDDW-2024-009694J. Paul Wright <pwright@utah.gov> Johnson Canyon Well #4 (WS006) File #15254 - Review Comments Brent Gardner <brentgardner@alphaengineering.com>Tue, Jul 30, 2024 at 3:14 PM To: "J. Paul Wright" <pwright@utah.gov> Cc: Glen Carnahan <glencarnahan@alphaengineering.com>, "Dale Gardner (info@gardnerbrothersdrilling.com)" <info@gardnerbrothersdrilling.com>, Mike Noel <mnoel5603@gmail.com> Mike Noel called and I thought Glen had taken care of this but not sure if you have seen a response. I still need to speak to Mike Noel as PVC screen is also less efficient in allowing water through the screen which creates more head for pumping but the attached is for PVC Casing and Screen. Attached are the red lines that I believe address the specifications and a clean copy is also provided. My responses to each of the questions are below: Brent E. Gardner, PE brentgardner@alphaengineering.com 43 South 100 East, Suite 100 • St George, Utah 84770 T: 435.628.6500 • F: 435.628.6553 • alphaengineering.com From: J. Paul Wright <pwright@utah.gov> Sent: Thursday, July 11, 2024 4:24 PM To: Glen Carnahan <glencarnahan@alphaengineering.com>; Brent Gardner <brentgardner@alphaengineering.com> Cc: amanda.buhler@kcwcd.com; Kane County Water Conservancy District <kanecowater@gmail.com>; Mike Noel <mnoel5603@gmail.com> Subject: Johnson Canyon Well #4 (WS006) File #15254 - Review Comments Glen and Brent, I have reviewed the drilling plans for the Kane County WCD - Johnson Canyon (13038), Johnson Canyon Well #4 drilling project and I have some questions/comments. 1) The bid schedule (Section 107, Bid Item 1.2) shows that a 20" borehole and 20" casing will be installed. I have a couple of questions and some corrections needed: The borehole needs to be at least 4 inches larger in diameter to accomodate a proper grout seal. The drawing calls out at least a 2-inch annular space, but does not specify the minimum borehole diameter. The bid schedule should be corrected to reflect this. Changed to a 26” diameter hole being drilled for the top 100 feet with a 22” 0.312 wall steel carrier casing being installed. The 20-inch conductor casing type (steel I assume) and thickness have not been specified, this needs to be clarified. Clarified above. 7/30/24, 3:22 PM State of Utah Mail - Johnson Canyon Well #4 (WS006) File #15254 - Review Comments https://mail.google.com/mail/u/0/?ik=f3bcb897f8&view=pt&search=all&permmsgid=msg-f:1806040157085995790&simpl=msg-f:1806040157085995790 1/2 2) The bid schedule (Section 107, Bid Item 1.4) shows that a 20" borehole will be drilled to the bottom of the hole, however the drawing shows the borehole being slightly smaller than 20 inches. Obviously, once the conductor casing (20-inch) is installed, it needs to sit on that shelf, the borehole to the bottom should be smaller than 20 inches in diameter. This should be corrected. Corrected above. 3) The well detail at the end of the specifications calls out PVC SDR 17, 12-inch casing and PVC SDR 17, 12-inch slotted well screen. But Bid Item 1.7 calls out the PVC SDR 17 slotted screen and stainless steel spacers, so this discrepancy needs to be resolved. Specification modified to include only PVC SDR 17 screen and casing. 4) From what I can tell, you are planning a 12-inch steel casing for the top 300 feet of the well and the PVC well casing below that to a depth of 600 feet. In looking online, it appears that PVC SDR 17, 12-inch well casing should only be installed to a maximum depth of 450 feet (see table below). You will need to provide proof that this casing can be used at these depths. Also, I need you to verify that the PVC being used is marked "Well Casing " and meets ASTM 480-14 according to R655-4. Attached is the Johnson Screen information for the well screen and casing. The tensile strength of the screen is listed at 36,200 lbs. The weight of the screen is 18.89 lbs/ft which is less than the well casing pipe. If we use the casing weight of 19.18 lbs the total hanging weight for 600 feet is 11,508 lbs so there should not be an issue with depth as far as weight of screen and casing as the total allowable is 36,200 lbs. I verified this with Johnson Screen. [Quoted text hidden] [Quoted text hidden] 3 attachments Flush-Thread-PVC-Wells-Screens-Casings-Accessories.pdf 3035K Johnson Canyon Well #4 Drilling Specification BG Red Lines (002).pdf 526K Johnson Canyon Well #4 Drilling Specification without Red Lines (002).pdf 526K 7/30/24, 3:22 PM State of Utah Mail - Johnson Canyon Well #4 (WS006) File #15254 - Review Comments https://mail.google.com/mail/u/0/?ik=f3bcb897f8&view=pt&search=all&permmsgid=msg-f:1806040157085995790&simpl=msg-f:1806040157085995790 2/2