Loading...
HomeMy WebLinkAboutDERR-2024-009389Underwood Environmental Consulting, Inc. 1 July 31, 2024 Mr. Mark Crim Department of Environmental Quality Division of Environmental Response and Remediation P.O. Box 144840 Salt Lake City, Utah 84114-4840 Re: Soil Vapor Sampling Plan Former Calvinco Co. (Intermountain Lock) 3106 South Main Street South Salt Lake, Utah Facility ID #4000124, Release Site OBL Dear Mr. Crim, Based on previous correspondence, two temporary soil vapor sampling points located outside the building footprint itself are proposed. One would be placed near MW-5 and the other near MW-7 (Figure 1). Each sampling point would be emplaced through the 8” thick concrete slab a few feet from the actual monitoring wells. Vapor pins® would be installed by a qualified drilling subcontractor. Vapor samples would subsequently be collected from the subsurface using summa cans. Air sampling protocol outlined in the DERR PST Environmental Media Sampling Handbook (June 1, 2021) would be followed. The vapor samples would be analyzed using EPA method TO-15 for MTBE, BTEXN, and TPH gas (C5-C12). The vapor pins® would be removed and the drill holes patched immediately after sampling. The analytical results of vapor sampling would be compared with June 2015 Utah DERR RBCA commercial sub-slab guidance, or other pertinent guidance. A brief letter report would be prepared and transmitted to stakeholders. A rendering of the ground floor of the IML building is attached as Figure 2. Respectfully, Underwood Environmental Consulting, Inc. L. Earl Underwood, P.G. Sr. Geologist, CC-0018 enclosures: Figure 1 - Soil Vapor Sampling Plan Figure 2 – Ground Floor Rendering LEGEND approx. scale in feet one inch ~ 30 feet 00 3015 Former Calvinco Co. (Intermountain Lock) 3106 South Main St. South Salt Lake, Utah Facility ID # 4000124 Release Site OBL NORTH W SD Natural Gas Water Line G W S (Utility Locations Approximate) Power or Unknown SD Storm Drain CommunicationsC P Sanitary Sewer U GG C S U P SD SD C W C C U S S SD P U U Ma i n S t r e e t Angelo Avenue Intermountain Lock Security Supply Closed-in-Place Diesel UST Gr a c e M a r y M a n o r FIGURE 17/31/2024 MW-2 Monitoring Well B-1 Soil Boring Soil Boring (Western Geologic, 2021b) GP-01 91.17 Groundwater Elev. (ft) 9 1 Groundwater Contour Line (contour interval = 0.1 ft) Groundwater Flow Direction Soil Vapor Sampling Plan (July 2024) B-2 B-1 GP-01 GP-02GP-03 GP-04 GP-05 MW-3 MW-1 MW-2 MW-4 MW-6 MW-5 MW-7 V V V Proposed Soil Vapor Sample Point LEGEND approx. scale in feet one inch ~ 30 feet 00 3015 Former Calvinco Co. (Intermountain Lock) 3106 South Main St. South Salt Lake, Utah Facility ID # 4000124 Release Site OBL NORTH W SD Natural Gas Water Line G W S (Utility Locations Approximate) Power or Unknown SD Storm Drain CommunicationsC P Sanitary Sewer U GG C S U P SD SD C W C C U S S SD P U U Ma i n S t r e e t Angelo Avenue Intermountain Lock Security Supply Closed-in-Place Diesel UST Gr a c e M a r y M a n o r W ARE H O U S E SHO W R O O M ST AIRS SHI P P I N G / REC E I V I N G P ARK I N G G A R A G E FIGURE 27/31/2024 MW-2 Monitoring Well B-1 Soil Boring Soil Boring (Western Geologic, 2021b) GP-01 91.17 Groundwater Elev. (ft) 9 1 Groundwater Contour Line (contour interval = 0.1 ft) Groundwater Flow Direction GROUND FLOOR RENDERING B-2 B-1 GP-01 GP-02GP-03 GP-04 GP-05 MW-3 MW-1 MW-2 MW-4 MW-6 MW-5 MW-7 V V V Proposed Soil Vapor Sample Point