HomeMy WebLinkAboutDDW-2024-008764Water/Sewer Separation - Exception Request Form INSTRUCTIONS Send the completed Exception Request Form, drawings, and Water/Sewer Exception Request Spreadsheet to ddwpnf@utah.gov PROJECT INFORMATION Water System Number*:DDW File Number: Water System Name*: Project Title*: Project Description*: Attachments:Drawings of water line and sewer line alignments Water/Sewer Exception Request Spreadsheet SUBMITTED BY Engineer of Record Name (Print): PE License Number: Title: Email: Phone: Organization: Signature: Date: REVIEWED BY DDW Permitting Engineer Name (Print) Date: APPROVED BY DDW Permitting Manager Name (Print): Signature: Date: Enclosures: CC: Digitally signed by DALLAS BUCKNER DN: cn=DALLAS BUCKNER, c=US, o=GO CIVIL ENGINEERING, email=DALLAS@GOCIVIL.NET Date: 2024.06.11 16:22:16 -06'00' DALLAS BUCKNER 11002 CEDAR CITY MUNICIPAL WATER (CULINARY) 50 S., 4375 & CENTER ST. ROAD IMPROVMENTS DALLAS BUCKNER 10622248 PRINCIPAL DALLAS@GOCIVIL.NET 435-586-9592 GO CIVIL ENGINEERING 6-11-24 J. Paul Wright, P.E.6-17-24 Michael Newberry, P.E. ROAD DEDICATION/IMPROVEMENTS PLAN WITHIN THE IRON WEST PROJECT BOUNDARY FOR RESIDENTIAL DEVELOPMENT. Jeremy Robert, Southwest Utah Public Health Dept. jroberts@swuhealth.gov Dallas Buckner, P.E., Go Civil Engineering, dallas@gocivil.net Robbie Mitchell, Cedar City Waterworks, mrobbie@cedarcity.org J. Paul Wright, P.E., DEQ Southwest District Office, pwright@utah.gov Nagendra Dev, Division of Drinking Water, ndev@utah.gov Exception Request Spreadsheet Is a Water/Sewer Separation Exception Required per R309-550-7? Are all requirements of R309-500-7(3)* met? No. Exception required Yes. Do water and sewer cross? No. Is there at least 10' of horizontal separation? No. There at least 6' of horizontal separation, sewer pipes in good condition, AND there is not high groundwater? Yes. Is water at least 18" above the sewer? Yes. Exception not required No. Exception required No. Exception required Yes. Exception not required Yes. Is water at least 18" above sewer? No. Exception required Yes. Exception not required Requirements of R309-500-7(3) are met if: The groundwater is not high Water transmission lines that may become unpressurized will not be installed within 20 feet of sewer lines Disturbances of existing lines are prevented or minimized Corrosive conditions do not exist When sewer force main crosses under existing water main, all portions of the sewer force main within 10’ (horizontally) of the water main will be enclosed in a continuous sleeve When a new water main crosses over an existing sewer force main, the water main will be constructed of pipe materials with a minimum rated working pressure of 200 psi or equivalent pressure rating Water service laterals will conform to requirements for separation of water and sewer lines Water/Sewer Separation - Exception Request Spreadsheet 0+37.50, SHEET 4 2+73.23 SHEET4 3+62.21 SHEET4 CONST. TO EX. SWR.CONST. TO EX. SWR.CONST. TO EX. SWR. X-ING X-ING X-ING 0.54 1.37 1.23 ABOVE ABOVE ABOVE >12'>12'>12' Condition (New/Existing)NEW NEW NEW Material DUCTILE DUCTILE DUCTILE Size 16"8"8" Pressure Rating 350 PSI 350 PSI 350 PSI Is the line pressurized year-round?YES YES YES Condition (New/Existing)NEW NEW NEW Material PVC PVC PVC Size 8" MAIN 4" LATERAL 4" LATERAL Pressure Rating N/A GRAVITY N/A GRAVITY N/A GRAVITY Is the line pressurized?NO NO NO 20' PVC sleeve on sewer line per Detail Sheet 11 centered on crossing 20' PVC sleeve on sewer line per Detail Sheet 11 centered on crossing 20' PVC sleeve on sewer line per Detail Sheet 11 centered on crossing 1. Separation distances shall be measured edge-to-edge. 2.     Examples of proposed means to mitigate risks include: a.     remove/replace the aged vitrified clay sewer pipe; b.     replace the aged or cracked existing sewer pipe; c.      use thicker or higher pressure class PVC instead d.     of the typical thin-wall sewer pipe; install an in-situ lining to the existing sewer pipe for XX feet; e.     center the sewer line over the crossing to keep the joints as far as possible from the water line; f.      add detectable or magnetic warning tape placed 12 inches above the sewer and/or the water line(s) to minimize possible damage during future excavations; g.     use HDPE pipe for water line or sewer line to eliminate the joints [if there is no sagging or lack-of-sufficient slope problems for HDPE sewer pipes]; h.     use restrained joints for water line and/or sewer line near the crossing Sewer Line Water Line Reason for not meeting R309-550-7 Mitigation Efforts2 Station or Location Horizontal Clearance1 Vertical Clearance1 Water is Above or Below Sewer Groundwater conditions 4+51.23 SHEET 4 5+40.23 SHEET 4 6+98.23 SHEET 4 14+51.12 SHEET 7 CONST. TO EX. SWR.CONST. TO EX. SWR.CONST. TO EX. SWR.CONST. TO EX. SWR. X-ING X-ING X-ING X-ING 1.15 1.07 0.98 1.21 ABOVE ABOVE ABOVE ABOVE >12'>12'>12'>12' NEW NEW NEW NEW DUCTILE DUCTILE DUCTILE DUCTILE 8"8"8"16" 350 PSI 350 PSI 350 PSI 350 PSI YES YES YES YES NEW NEW NEW NEW PVC PVC PVC PVC 4" LATERAL 4" LATERAL 4" LATERAL 4" LATERAL N/A GRAVITY N/A GRAVITY N/A GRAVITY N/A GRAVITY NO NO NO NO 20' PVC sleeve on sewer line per Detail Sheet 11 centered on crossing 20' PVC sleeve on sewer line per Detail Sheet 11 centered on crossing 20' PVC sleeve on sewer line per Detail Sheet 11 centered on crossing 20' PVC sleeve on sewer line per Detail Sheet 11 centered on crossing