HomeMy WebLinkAboutDSHW-2019-000666 - 0901a0688098e6bdJanuary 14, 2019
Scott T. Anderson, Director
Department of Environmental Quality
Division of Waste Management and Radiation Control
P.O. Box 144880
Salt Lake City, Utah 84114-4880
Div of Waste Management and Radiation Control
JAN 1 5 2019
7)6kW-240/9-00/%66
RE: ATK Launch Systems, Inc. — Bacchus Facility UTD001705029
Hazardous Waste Storage Permit Module II.D.5.c Submission
ATK Launch Systems, Inc. — Bacchus Facility — NIROP, UT3170027277
Hazardous Waste Storage Permit Module II D.5.c Submission
,vfii..TK Launch Systems, Inc. — Promontory Facility UTD009081357
Hazardous Waste Storage Permit Module II.D.6.c Submission
Dear Mr. Anderson,
ATK Launch Systems, Inc. has an annual requirement to update the parameters, analytical methods and
sample preparation methods listed in the referenced documents. There is only the addition of a perchlorate
method (EPA 6850) to the previous year's methods. Please direct any question about this submission to
Blair Palmer at (435) 863-2430.
I certjbl under penalty of law that this document and all attachments were prepared under my direction or
supervision in accordance with a system designed to assure that qualffied personnel properly gather and
evaluate the information submitted. Based on my inquiry of the person or persons who manage the
system, or those persons directly responsible for gathering the information, the information submitted is,
to the best of my knowledge and belief true, accurate, and complete. I am aware that there are
significant penalties for submitting false information, including the possibility offine and imprisonment
for knowing violations.
Kris H. Blauer, Manager,
Manager, Environmental Services
C: J. Vandel
Z. Hao
ATK Launch Systems, Inc. • P.O. Box 707 Brigham City, Utah 84321 • (801)250-5911
Figure 3-4
Anal tical Methods for Metals
Parameter Analytical Method Preparation Method 1
Arsenic EPA 6010C EPA 3005A (W) & 3050B (S)
Barium EPA 6010C EPA 3005A (W) & 3050B (S)
Beryllium EPA 6010C EPA 3005A (W) & 3050B (S)
Boron EPA 6010C EPA 3005A (W) & 3050B (S)
Cadmium EPA 6010C EPA 3005A (W) & 3050B (S)
Chromium EPA 6010C EPA 3005A (W) & 3050B (S)
Copper EPA 6010C EPA 3005A (W) & 3050B (S)
Lead EPA 6010C EPA 3005A (W) & 3050B (S)
Manganese EPA 6010C EPA 3005A (W) & 3050B (S)
Mercury EPA 7470A (W) & 7471B (S) EPA 7470A (W) & 7471B (S)
Molybdenum EPA 6010C EPA 3005A (W) & 3050B (S)
Nickel EPA 6010C EPA 3005A (W) & 3050B (S)
Selenium EPA 6010C EPA 3005A (W) & 3050B (S)
Silver EPA 6010C EPA 3005A (W) & 3050B (S)
Thallium EPA 6010C EPA 3005A (W) & 3050B (S)
Vanadium EPA 6010C EPA 3005A (W) & 3050B (S)
Zinc EPA 6010C EPA 3005A (W) & 3050B (S)
Analvtical Methods for Or anics
Parameter Analytical Method Preparation Method
Volatile Organics EPA 8260B EPA 5030C (W) & 5035A (S)
Semi-volatile Organics EPA 8270D EPA 3510C (W) & 3550C (S)
TPH EPA 8015D EPA 3510C (W) & 3550C (S)
TOC EPA 9060A (W only) EPA 9060A (W only)
Oil & Grease EPA 1664A (W only) EPA 1664A (W only)
Miscellaneous Test Methods
Parameter Analytical Method Preparation Method
pH EPA 9040C (W) & 9045D (S) EPA 9040C (W) & 9045D (S)
Ignitability EPA 1010A (W only) EPA 1010A (W only)
Toxicity EPA 6010C/7470A (Metals/Hg)
EPA 8260B (Volatile Organics)
EPA 8270D (Semi-volatile Organics)
EPA 1311 Followed by 3010A/7470A2
EPA 1311 Followed by 5030C
EPA 1311 Followed by 3510C
Explosives EPA 8330A EPA 8330A
Perchlorate
EPA 314.0
EPA 6850
EPA 314.0
EPA 6850
Anions EPA 9056A EPA 9056A (W) & 5050 (S)
TSS SM 2540D SM 2540D
TS SM 2540B SM 2540B
1. The 'W' indicates a water matrix. Samples that are water soluble liquids (or aqueous phase) fit into this
category. Non-aqueous liquids are usually treated as solids depending on the test method. In the case of an
oil matrix that cannot be analyzed by the solid preparation method, a waste dilution is often performed.
The 'S" indicates a solid matrix.
2. Mercury will be prepared using Method 7470A.