HomeMy WebLinkAboutDSHW-2015-007993 - 0901a0688054f8eaOrbital ATK/J
July 29, 2015
8200-FY16-026 Div of Waste Management
and Radiation Control
Mr. Scott T. Anderson, Director
Utah Department of Environmental Quality •'UL Z 9 2015
Division of Waste Management and Radiation Control
195 North 1950 West
P.O. Box 144880
Salt Lake City, Utah 84114-4880
Re: ATK Launch Systems Inc., Solid Waste Management Unit 553 Additional
Investigation, Promontory EPA ID #UTD009081357
Dear Mr. Anderson:
Jeff Vandal, with your office, proposed that the ATK Promontory Facility review a group
of eight Solid Waste Management Units (SWMUs) and, as needed, conduct additional
investigations. Then based on this additional information, determine if they could be
closed with no further action. These SWMUs had previously been investigated and the
results reported in the Promontory RCRA Facility Investigation (RFI) Phase 1, August
2000 report. One ofthe SWMUs is 553, associated with the M-19A facility and the
historic discharge of photographic wastewater to a drainage channel.
A review of the RFI report for SWMU 553 shows that the contaminants of concern were
primarily silver and chromium. Eleven samples were collected within the drainage
channel. Only one indicated a high value for total chromium at 506 mg/kg, this was a
sample 50' down gradient in the drainage channel and 2 feet deep. All the other samples
showed typical background levels for total chromium. There were varying values for
silver that were above background but below risk based levels. Therefore, the only
potential concern is if the sample location containing the high total chromium value has a
chromium (VI) value that may exceed the June 2015 EPA Regional Screening Level
(RSL) of 0.3 ppm for residential exposure.
An additional investigation was conducted on August 8,2014 with another sample
collected 50 feet down gradient of the start of the channel and two feet deep. The sample
was analyzed for total chromium, total silver and chromium (VI). Results of the
sampling showed values similar to the original RFI drainage samples for total silver. The
total chromium value was 19 ppm. Although it is less than the previous 506 ppm it is
similar to the other original samples from the channel, indicating that the earlier high
value is likely an outlier. The chromium (VI) analysis shows a value of non-detect with a
0.214 ppm detection limit. A copy of the laboratory report is attached to this letter.
Orbital ATK, Inc. • P.O. Box 707, Brigham City, UT 84302 • 435-863-3511
Orbital ATK
Based on the previous RFI sampling and this additional investigation, we conclude that
chromium concentrations in the drainage channel are the chromium III form, and do not
exceed the current residential risk based level of 120,000 ppm found in the EPA RSL
table. ATK recommends that SWMU 553 be closed with a no further action designation.
If you have questions regarding this letter, please contact Paul Hancock at (435) 863-
3344.
Sincerely,
George E. Gooch
Manager, Environmental Services
ATK Launch Systems
Orbital ATK, Inc. • P.O. Box 707, Brigham City, UT 84302 • 435-863-3511
988P LS336
CERTIFICATE OF ANALYSIS
Listing of Sample Information and Testing Requested
Monday, September 22, 2014
TESTED FOR: ATK: DLV
Environmental Monitoring
Thiokol Corp, UT 84322
Analytical Chemistry Laboratory
P.O. Box 707, M/S 245
Brigham City, UT 84302-0707
435-863-3732
435-863-8080
ANALYZED BY: ATK Launch Systems
Contact Name: Paul Hancock
Project:
Sample Delivery Group:
Solid Waste Management - DLV
1408005
Page 1 of 4
Printed: 09/22/1415:02
Sample Delivery Group: 1408005
Sample No. Client No.
Test Requested Sample Description
Received Collect Date/Time
Matrix
1408005-01 1 - 50' Down Gradient 19A Storm Drainage 08/08/14 8/8/2014 09:10:00
MOISTURE
SW-846 Method 7199
SW-846, 3050B
SW-846, 3060A
SW-846, 6010B (Solids)
Percent Moisture
Cr (VI) Metals Analysis by IC
ICP/GFAA Metals Digestion
Alkaline Digestion for Hexavalent Chromium
Metals Analysis by ICP - 6010B
Soil
Soil
Soil
Soil
Soil
Certified By: 09/22/2014
W. Scott Fraser, Quality Assurance Officer Date
This certifies that the following data meets the requirements ofthe National Environmental Laboratory Accreditation
Program (NELAP) unless otherwise annotated:
Page 2 of 4
Printed: 09/22/14 15:02
Listing of Results by Sample
Sample Delivery Group: 1408005
Client Sample ID: 1 - 50' Down Gradient 19A Storm Drainage
Sample Description: ATK-DLV -19 A Storm Drainage
Laboratory Sample ID: 1408005-01
Date Sampled: 08/08/14 09:10
Moisture: 6.4%
CAS Number Test Parameter Result (Dry Wt) Units MDL
Dilution
EQL Factor Analyst Test Date
[ Test Method: MOISTURE Percent Moisture
MOISTURE 6.4 MDP
Test Method: SW-846Method 7199 Cr (VI) Metals Analysis by IC
18540-29-9 CHROMIUM HEXAVALENT ug/kg 2.14 10.7 1 CRS 08/27/14
i Test Method: SW-846,3050B ICP/GFAA Metals Digestion
3050B ACID DIGESTION DATE 08/22/2014
Test Method: SW-846, 3060A Alkaline Digestion for Hexavalent Chromium
MTB 08/22/14
3050B ACID DIGESTION DATE 08/26/2014 CRS 08/26/14
Test Method: SW-846,6010B (Solids) _ Metals Analysis by ICP-6010B
7440-47-3 CHROMIUM 19.
7440-22-4 SILVER 93.1
ug/g
ug/g
1.1
0.1
5.3
0.5
MTB
MTB
08/26/14
08/26/14
Printed:
Page 3 of 4
09/22/14 15:02
Data Reporting Qualifiers
u
B
J
MDL
EQL
Dilution
Factor
Indicates that the analyte concentration is less than the MDL.
This flag is used when an analyte is found in the blank as well as the sample.
Indicates an extimated value. This flag is used either when estimating a concentration
for tentatively identified compounds or when the data indicated the presence of a
compound that meets the identification criteria but the result is less than the
EQL (e.g. 3 J with an EQL of 10).
Method Detection Limit: The minimum concentration of a substance that can be
confidently measured and reported. The laboratory has demonstrated that the
MDL can be achieved in a laboratory reagent blank, but does not guarantee it
can be achieved in all sample matrices.
Estimated Quantitation Limit: The EQL generally is 5 to 10 times the MDL. For
many analytes the EQL is selected as the value of the lowest standard in the
calibration curve.
Dilution Factor: The prepared sample was diluted by this factor because the
sample was too concentrated or due to other interferences in the sample matrix.
Any dilution factor causes a corresponding increase in the MDL and EQL.
Page 4 of 4
Printed: 09/22/1415:02
ATK Space Systems Group
Environmental Laboratory
Client Name
Sample Receipt Checklist
SDG No
Carrier. gut Hand delivered, no coolor
Carrier Number
inland delivered, sample^) taken out at receiving counter Initials:
Cooler Information: . _ /
Cooler Number/IP: <^^Vlfc.Lv fc&tA.
Condition or Shipping Container.
Cooler Seated (taped):
Custody Seats Present:
Coolant:
State of Coolant:
Thermometer P: Sfffilffi?
Packing Description:
•doc Fair
U4o Ye*
lYes
Intact NBrotten
t*dce Blue les
rozan
Reading
Not Applicable
i, Not Applicable
; iNot Applicable
^Damaged (explain) _
'None
'Partially frozen
< C "C CF: ~
Seal Number.
Other:
'Melted
Corrected Temp:. Temp Blank Inctudad: (Yes ("rtfo"
Chain-Of-Cuttody Information:
COC Present:
COC I
COCi
COC or LWI agrees wtti sample labels:
: Present rr-jn irAQ t*"S» iNunberts): H9yn /
: signed (reJinoutehad end received): ^riVes
yffrlo Other
i/Yes
UNO
I No
I INot Applicable
I INot Applicable
Notes:
Sample Information: , , ^ , . t _
Samples Included In cooler: \%tj+0&> — j !)C W*L- V/l^
Custody Sesls Present
Sample contajners Intact:
Samples ki proper containers;
Surfidant sample volume:
Al
11 Yes
fimtact
terras
If*
ltime: VJY«S
Water- VOA's have zaro headspace:
nPnvpreaerved wtth HCt
Notes-.
Otner.
tjBroken Seal Number(s) _
nWo Notes:
(Mo
UNo
ftto
nYes UNo fcd$otAppBcaole
t lPre-|JBi«iYSU otft NaAOfr QNorvPreeorved:
Water-pH acceptable upon receipt flYes
HNO,= H^O, -
l lAdjusted (see comments below) j^HoTApplicable ~
NaOH = ZnAC /NeOH >
Water • pH adjusted: (mfg. S Lot No.)
HNOj HjSO. _NaOH. ZnAC
NaJSOJOj
Notes:
Other
_HCL =
HCi
SOP-102 Form A
1408005
ENVIRONMENTAL LAB WORK REQUEST
TO-. ATK LAUNCH SYSTEMS INC. ENVIRONMENTAL LABORATORY LWRNO.E13549
Login No.
ocJ-—
EXTENSION: COST CENTER:
8200
WORK ORDER: X
988P/LS33J
ORGANIZATION:
ENVIRONMENTAL SERVICES
MAO. STOP:
301
SAMPLE INFORMATION
REPORT RESULTS TOi
SAMPLE DATE TYPE LOCATION TIME TEST REMARKS
X
CHAIN OF CUSTODY
RELINQUISHED BY RECEIVED BY DATE TIME
FOR LABORATORY USE ONLY
DATE COMPLETED DATE REPORTED