Loading...
HomeMy WebLinkAboutDSHW-2011-014435 - 0901a068802eab0aState of Utah GARYR. HERBERT Governor GREG BELL Lieutenant Governor Dave P. Gosen, P .E. Department of Environmental Quality Amanda Smith Executive Director DIVISION OF SOLID AND HAZARDOUS WASTE Scott T. Anderson Director December 16, 2011 Director, Environmental Services ATK Launch Systems -Promontory P.O. Box 707 Brigham City, UT 84302-0707 RE: Class 1 Storage Permit Modification Request UTD009081357 Dear Mr. Gosen: Solid and Hazardous Waste Control Board Kevin Murray, Chair Kory Coleman, Vice-Chair Brian E. Brower Scott Bruce Jeff Coombs, MPH, LEHS R. Ryan Dupont, Ph.D. Larry A. Ellertson Brad Mertz Brett Mickelson GaryMossor Dennis Riding Dwayne Woolley Amanda Smith Scott T. Anderson Executive Secretary The Division of Solid and Hazardous Waste has completed its review of ATK' s Storage Permit modification request, received on December 8, 2011, to expand the hours of operation at theM- 136 and M-225 Burn Grounds. The Division has determined that this is a Class 1 permit modification that requires prior approval. The purpose for expanding the hours of operation (from 10:00 am to 6:00pm to the proposed 6:00 am to 6:00pm) is to provide ATK with the ability to conduct open burns in the morning hours when winds are sometimes out of the north. This added operational flexibility will allow A TK to conduct burns where the generated smoke can blow back across ATK's large property and not towards off-site communities located to the north and east. The permit modification is hereby approved. The modification to Condition IV.C.6.c is enclosed. Please make copies as necessary and replace this page in your copies of the Storage Permit at Promontory. In accordance with 40 CFR §270.42(a)(ii), ATK must send a notice of the modification to all persons on the facility mailing list, and the appropriate units of State and local government, within 90 days after this approval. TN201101321 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144880 • Salt Lake City, UT 84114-4880 Telephone (801) 536-0200 • Fax (801) 536-0222 • T.D.D. (801) 536-4414 www.deq.utah.gov Printed on I 00% recycled paper If you have any questions, please contact JeffVandel at (801) 536-0257. ~ Scott T. Anderson, Executive Secretary Utah Solid and Hazardous Waste Control Board STA/N/tjm Enclosure c: Nancy Morlock, US EPA Region VIII George Gooch, ATK Launch Systems Lloyd Berentzen, MBA, Health Officer, Bear River Health Department TN20ll01321 2 ATK Launch Systems Inc.-Promontory Modified December 15, 2010 UTD009081357 Module IV-Thermal Treatment of Energetic Wastes IV.C.6.b. IV.C.6.c. IV.D. IV.D.l. IV.E. IV.E.l. IV.E.1.a. IV.E.l.b. IV.E.1.c. IV.E.1.d. IV.E.1.e. IV.E.l.f. IV.F. IV.F.l. The Permittee shall only conduct bums when the surface wind speed is not greater than 15 miles per hour; and The Permittee may conduct bums and open detonations only between the hours of 6:00 am and 6:00pm. WASTE TRACKING The Permittee shall track all reactive hazardous waste in accordance with Attachment 11 and maintain this information in the operating record for both of the Promontory Thermal Treatment Areas. PRE-BURN ACTIVITIES Prior to bringing any reactive hazardous waste into either of the Promontory Thermal Treatment Areas for thermal treatment, The Permittee shall conduct pre-bum activities in accordance with the requirements identified in Attachment 11, and the pre-bum inspection requirements in accordance with the inspection schedule included in Attachment 2. The Permittee shall also comply with the following conditions: If the treatment units have not been inspected the same day the unit is loaded, the treatment unit shall be inspected prior to placing reactive waste in the treatment unit; Any treatment unit that fails one or more of the inspection criteria shall be removed from service until the problem is corrected; No treatment is permitted unless either radio or telephone communication with emergency services is available; No treatment is permitted if the emergency equipment listed in Attachment 2, Table li-B, "Inspection Schedule for Thermal Treatment Area at M-136" or Table II-<;::, "Inspection Schedule for Thermal Treatment Areas at M-225" is not available for use at each respective location; All leaks or spills of diesel fuel shall be cleaned up before the Promontory thermal treatment areas can be operated; and The loss of the flashing light will require that the unit be shut down until the problem is corrected. If the Permittee must use the treatment unit when the flashing light is not working, the supervisor shall visually inspect the area within the QD of the treatment unit and assure that no unauthorized employees are present in the area. If any unauthorized employees are found within this area, they will be escorted from the area. Treatment operations can commence once the supervisor verifies in the operating record that the area is clear. PREPARING WASTE FOR THERMAL TREATMENT BURN Prior to placing any reactive hazardous waste in a treatment unit, the Permittee shall comply with all provisions Conditions IV.C, D and E of this Permit. The Permittee shall also comply with the following conditions: Page 5