HomeMy WebLinkAboutDDW-2024-00872818026 14527 Salt Lake City WS 925 S 4400 W Building Addition BRYAN K SCHMUTZ 4777990 CIVIL ENGINEER BRYANS@ADVANCEDCIVILENGINEERING.COM (801) 884 6010 ADVANCED CIVIL ENGINEERING, PLLC 6/27/24 Rebecca Yoo 6/28/2024 Michael Newberry, P.E. Install a proposed 8" sewer lateral 0.57' under the existing 12" PVC water main. Sewer shall be PE3408 fused HDPE DR17 with flexible gasketed joints at the manholes. Includes leakage test, deflection test, and video inspection Matthias Neville, Salt Lake County Health Department, mrneville@slco.org Bryan Schmutz, Advanced Civil Engineering, bryans@advancedcivilengineering.com Teresa Gray, SLC Water System, teresa.gray@slcgov.com Rebecca Yoo, Division of Drinking Water, ryoo@utah.gov Water/Sewer Separation - Exception Request Spreadsheet STA 76+52 4400 West Constraint due to existing water main and gravity sewer elevation. Perpendicular crossing 0.57 feet Above 18" below water main Condition (New/Existing)Existing 1996 Material PVC Size 12" Pressure Rating 150 psi (107 static) Is the line pressurized year-round?Yes Condition (New/Existing)Proposed 2024 Material fused HDPE DR17 Size 8" Pressure Rating 150 psi Is the line pressurized?No Maintain existing water main in place without adding additional joints in the area; Sewer shall be PE3408 fused HDPE DR17 with QC testing per DEQ; add magnetic warning tape 12" above water and sewer lines 1. Separation distances shall be measured edge-to-edge. 2.     Examples of proposed means to mitigate risks include: a.     remove/replace the aged vitrified clay sewer pipe; b.     replace the aged or cracked existing sewer pipe; c.      use thicker or higher pressure class PVC instead d.     of the typical thin-wall sewer pipe; install an in-situ lining to the existing sewer pipe for XX feet; e.     center the sewer line over the crossing to keep the joints as far as possible from the water line; f.      add detectable or magnetic warning tape placed 12 inches above the sewer and/or the water line(s) to minimize possible damage during future excavations; g.     use HDPE pipe for water line or sewer line to eliminate the joints [if there is no sagging or lack-of-sufficient slope problems for HDPE sewer pipes]; h.     use restrained joints for water line and/or sewer line near the crossing Sewer Line Water Line Reason for not meeting R309-550-7 Mitigation Efforts2 Station or Location Horizontal Clearance1 Vertical Clearance1 Water is Above or Below Sewer Groundwater conditions