Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DDW-2024-008601
National Flood Hazard Layer FIRMette 0 500 1,000 1,500 2,000250 Feet Ü SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT SPECIAL FLOODHAZARD AREAS Without Base Flood Elevation (BFE)Zone A, V, A99With BFE or DepthZone AE, AO, AH, VE, AR Regulatory Floodway 0.2% Annual Chance Flood Hazard, Areasof 1% annual chance flood with averagedepth less than one foot or with drainageareas of less than one square mileZone X Future Conditions 1% Annual Chance Flood HazardZone X Area with Reduced Flood Risk due to Levee. See Notes.Zone X Area with Flood Risk due to LeveeZone D NO SCREENArea of Minimal Flood Hazard Zone X Area of Undetermined Flood HazardZone D Channel, Culvert, or Storm Sewer Levee, Dike, or Floodwall Cross Sections with 1% Annual Chance 17.5 Water Surface Elevation Coastal Transect Coastal Transect Baseline Profile Baseline Hydrographic Feature Base Flood Elevation Line (BFE) Effective LOMRs Limit of Study Jurisdiction Boundary Digital Data Available No Digital Data Available Unmapped This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below.The basemap shown complies with FEMA's basemapaccuracy standards The flood hazard information is derived directly from theauthoritative NFHL web services provided by FEMA. This mapwas exported on 6/12/2024 at 12:06 PM and does notreflect changes or amendments subsequent to this date andtime. The NFHL and effective information may change orbecome superseded by new data over time. This map image is void if the one or more of the following map elements do not appear: basemap imagery, flood zone labels, legend, scale bar, map creation date, community identifiers, FIRM panel number, and FIRM effective date. Map images for unmapped and unmodernized areas cannot be used for regulatory purposes. Legend OTHER AREAS OF FLOOD HAZARD OTHER AREAS GENERAL STRUCTURES OTHER FEATURES MAP PANELS 8 B 20.2 The pin displayed on the map is an approximatepoint selected by the user and does not representan authoritative property location. 1:6,000 111°51'44"W 41°13'14"N 111°51'7"W 41°12'47"N Basemap Imagery Source: USGS National Map 2023 PS98i Submersible Pressure Transmitt er (4-20 mA) TYPICAL INSTALLATION APPLICATIONS Pump and slug tests River, stream, reservoir gauging Stormwater runoff monitoring Wetland monitoring Well, tank, tidal levels Flow monitoring Water resource management Landfi ll leachate levels Control applications Rugged and accurate with great noise immunity, transient protection, and thermal performance Features • Pressure and optionally temperature • Industry standard, 2-wire, 4-20 mA confi guration • Thermally compensated — great where water temperatures vary • ± 0.25% FSO accuracy • Low power (9 - 24 VDC) • Small diameter — 0.75” (1.9 cm) • Reverse polarity protection • Under- and over- current limitation • Built-in transient protection • Thermally stable • 2% over 50 degrees standard • 0.2% over 40 degrees with enhanced calibration option • 1/4” NPT end cone adapter option • Calibrated with patented calibration procedures and NIST traceable equipment Well seal with connections for cable and power (Optional) Cable strain relief (Optional) Cable AquiStar® Sensor 8902 122nd Avenue NE Kirkland, WA 98033 USA 425-822-4434 FAX 425-822-8384 / info@inwusa.com SALES & SERVICE LOCATIONS 4620 Northgate Boulevard, Suite 170 Sacramento, CA 95834 USA 916-922-2900 FAX 916-648-7766 / inwsw@inwusa.com ©2013 Instrumentation Northwest, Inc. All rights reserved. INW and AquiStar are registered trademarks of Instrumentation Northwest. Information in this document is subject to change without notice. Doc# 6D0011r17 05/17/13 PS98i Submersible Pressure Transmitt er (4-20 mA) GENERAL Length 8.3” (21.081 cm) Diameter 0.75” (1.9 cm) Weight 0.75 lb. (0.3 kg) Body Material Acetal & 316 stainless steel or titanium Wire Seal Material Fluoropolymer and PTFE Submersible Cable Polyurethane, polyethylene, or FEP available Desiccant 1-3 mm indicating silica gel (high or standard capacity) Terminating Connector Available Output 4-20 mA Operating Temp. Range -5° C to 70° C POWER Transmitter Voltage 9-24VDC (100 ms warmup) TEMPERATURE Element Type Thermistor Accuracy ± 0.3° C (typical) ± 0.75° C (maximum) Range -5° C to 70° C PRESSURE Transducer Type Silicon strain gauge Transducer Material 316 stainless steel or titanium Pressure Ranges Gauge FtH2O1 mH2O1 Absolute FtH2O1 mH2O1 2.3, 5.8, 12, 35, 69, 115, 231, 692 0.7, 1.75, 3.5, 10.5, 21, 35, 70, 210 46, 69, 115, 231, 692 14, 21, 35, 70, 210 Static Accuracy (B.F.S.L. 20° C) ± 0.25% FSO (maximum) ± 0.1% FSO (optional) Maximum Operating Pressure 1.1 x FS Burst Pressure2 3.0 x FS Compensated Range 0° C to 50° C 1 Higher pressure ratings available upon request2 Burst reduced at PSI>300 8.3”(21.081 cm) • Feet & Inches Display Ideal for Level Applications • Large Dual-Line 6-Digit Display, 0.60" & 0.46" • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Inputs • NEMA 4X, IP65 Front • Input Power Options Include 85-265 VAC or 12-24 VDC • Dual-Scale for Level and Volume – Single Input • Optional SunBright Display Models for Outdoor Applications • Isolated 24 VDC @ 200 mA Transmitter Power Supply • Signal Input Conditioning for Round Horizontal Tanks • Programmable Displays & Function Keys • 32-Point or Exponential Linearization • Multi-Pump Alternation Control • 2 or 4 Relays + Isolated 4-20 mA Output Options • External 4-Relay & Digital I/O Expansion Modules • RS-232, & RS-485 Serial Communication Options • Modbus® RTU Communication Protocol Standard (Slave) • Onboard USB and MeterView® Pro Programming Software FEET & INCHES PROCESS PD6001PROVU® Analog Input Feet & Inches Meter Precision Digital corPoration www.predig.com PR VUSERIES ® www.predig.com2 PD6001 PROVU® Analog Input Feet & Inches Meter Dual-Line 6-Character Display Large 0.6" Digits Rugged Front User Configurable Display (Showing custom tag) User Configurable Display Showing Feet & Inches to nearest 8th or 16th of an inch Programmable Function Keys Alarm Status Indicators UV Resistant Sunlight Readable Front Panel NEMA 4X Rated PD6001 INTRODUCTION The ProVu® PD6001 is a multi-purpose, easy-to-use digital process meter featuring a bright, highly visible main display with convenient feet and inches designations. It is ideal for level applications requiring a comprehensible display, as it shows feet, inches, and fractions of an inch to the nearest sixteenth of an inch. It accepts current and voltage signals (e.g. 4-20 mA, 0-10 V). Three of the front panel buttons can be custom-programmed for a specific operation. The analog input can be scaled to display the process in two different scales. The main display can indicate level in feet and inches with printed feet and inches designations, and the second display could be used to indicate some other scale, such as the volume in gallons or liters. The basic model includes an isolated 24 VDC transmitter power supply that can be used to power the input transmitter or other devices. An additional isolated 24 VDC power supply is included with the 4-20 mA output option. A digital input is standard. A fully loaded PD6001 meter has the following: four SPDT relays, 4-20 mA output, and two 24 VDC power supplies. The PD6001 capabilities may be enhanced by adding the following external expansion modules: four SPST relays (creating an eight-relay process meter), two digital I/O modules with four inputs and four outputs each, and USB, RS-232 or RS-485 communication adapters. The eight relays can be used for alarm indication or process control applications, such as pump alternation control. The 4-20 mA isolated output, Modbus RTU serial communications, and digital I/O options make the PD6001 an excellent addition to any level monitoring or control system. KEy FEATURES Precise, Accurate, and More Informative PROVU’s large 0.6" upper display provides a highly accurate and precise view of the process measurement in feet & inches, while the lower display provides a clearly identifiable custom tag. Its 24-bit A/D is accurate to ±0.03% of calibrated span ±1 count. The PD6001’s display also has lead zero blanking capability. Function Keys There are three function keys available to the user. These keys can be programmed to trigger certain events (i.e. acknowledge alarms, reset max and/or min, disable/enable output relays, or hold current relay states), provide direct menu access points, and more. Learn more about using the PROVU’s Function Keys by watching a video at predig.com/videos Standard LED and Optional SunBright LED Display Models The PROVU’s standard and SunBright display models feature extraordinarily bright LED displays. They are perfect for indoor and outdoor applications where visibility may be impaired by smoke, fog, dust, or distance. The intensity on the SunBright display model is so high it can be read even in the brightest sunlight. Free USB Programming Software & Cable The ProVu® comes preloaded with free MeterView® Pro programming software that connects and installs directly to your PC with a standard USB cable, also provided free with each instrument. This eliminates the need to insert CDs, install drivers, or download software from the internet. The software will allow you to configure, monitor, and datalog a ProVu® PD6001 using your PC. Just simply connect the meter to your PC with the USB cable and within minutes you will be programming it. Free USB Cable Included for Easy Software Installation www.predig.com3 PD6001 PROVU® Analog Input Feet & Inches Meter Dual-Scale Display Feature The PROVU PD6001 has a rather unique, and very flexible dual-scale capability; a second scaled display can represent the measured input in a different form (i.e. feet & gallons). This is of particular value in level applications. Please see the examples shown below. Both displays are independently scaled and are based on the 4-20 mA input signal. This function can be used for feet & gallons, feet & meters, feet & percent, feet & barrels, and more. Advanced Linearization Capability The PROVU includes a 32-point linearizer. In non-linear level applications (i.e. some pumping or lift stations), it can easily compensate for submerged equipment or plumbing that displace usable volume. A second independent 8-point linearizer is available for a second scaled display (PV2) when “Level” function is enabled. Precision Digital’s free MeterView Pro PC-based software greatly simplifies the construction of the linearization tables. The software can save this data to the meter and/or PC. On-Board Digital Input The PD6001 includes a digital input as standard. This digital input can operate with the interlock relays feature, force relays on from a signal from a PLC or relay on other equipment, and much more. This is ideal for installations where the meter is inaccessible behind a cover, or where an additional function key is needed for customized operation. P- COMP+V+ mA+ 3 41 2 5 F4 6 Max/Min Display Max/Min (or Peak/Valley) is standard on the PROVU PD6001. Either display can be configured to show either maximum or minimum excursion since last reset. The displays can also be configured to toggle between Max and Min values. Both values can be simply reset from the front panel. PROVU VIDEOS Watch a quick demonstration on how the PROVU works and also how the function keys can simplify functionality. These and other videos are available at www.predig.com/videos. Feet & MetersFeet & Gallons Feet & BarrelsFeet & Percent DIGITAL COMMUNICATIONS Modbus® RTU Serial Communications With the purchase of a serial communication adapter, PROVU meters can communicate with any Modbus Master device using the ever- popular Modbus communications protocol that is included in every PROVU. This greatly increases the flexibility of the meter. Modbus provides much more capability than read PV and write set points. Below are some examples of other things that can be done with PROVU’s Modbus communications. • Send a 6-character message to the lower display upon an event • Convert a digital value to a 4-20 mA signal • Remote user control (i.e. change set points, acknowledge alarms) • Input a Modbus digital PV (in place of analog input) • Remote override of any, or all, relays and analog outputs Remote MessageModbus PV Input Please see the following page for more information. Easy-to-Use The user friendly dual-line display makes the PROVU easy to set up & program. No jumpers to set for input selection. All setup & programming are done via the front panel. Three levels of password protection help maintain the reliability of the programming. Rugged & Durable A unique front panel design makes the PROVU nearly impenetrable in typical applications. Here, the PROVU easily survives a direct hit on the display from a heavy 2" solid stainless steel ball dropped from a height of eight feet. www.predig.com4 PD6001 PROVU® Analog Input Feet & Inches Meter PDA1232 & PDA1485 Communication Modules Serial communications on the PROVU can be added anytime with external PDA1232 (RS-232) or PDA1485 (RS-485) communication adapters. Free Modbus protocol included for use with PROVU serial communications modules. FIELD EXPANSION MODULES Add functionality to the PROVU in the field with easy-to-install external expansion modules. Add USB, RS-232, or RS-485 communications, I/O modules (up to 2), and 4-relay expansion module. The menu items for these modules do not appear until the module is connected, simplifying the basic menu. Relay and digital I/O modules are shown below with optional DIN rail mounting kit, P/N PDA1002. PDA1044 I/O Expansion Module Four digital inputs and four digital outputs are available per expansion module. The PROVU meter will accept two of these modules. External digital inputs can function similarly to the front panel function keys or on-board digital input F4. They can be configured to trigger certain events (i.e. acknowledge/reset alarms, reset max and/or min values, disable/enable all output relays, and hold current relay states), provide direct menu access point, or mimic front panel keys. The I/O module can be used to configure the PROVU remotely, in essence giving the user control of the four front panel push buttons. This feature is particularly useful if the meter is mounted inside an explosion-proof enclosure. Digital outputs can be used to remotely monitor PROVU’s alarm relay output states, or the states of a variety of actions and functions executed by the meter. PDA1004 Relay Expansion Module An external module containing four 3 A Form A (SPST) relays can be added to the PROVU at anytime. Removable screw terminal blocks accept 12 to 22 AWG wire. METERVIEw® PRO SOFTwARE Configure, monitor, and datalog a PD6001 from a PC using Meter View Pro Software (available with each ProVu meter via USB or for download at www.predig.com). Mo n i t o r & D a t a l o g Li n e a r i z a t i o n F e a t u r e Se t u p Re l a y s 10,0,0 6,0,0 20,0,0 12,6,0 30,0,0 18,0,0 40,0,0 24,6,0 www.predig.com5 PD6001 PROVU® Analog Input Feet & Inches Meter OUTPUTS Relay Outputs The PROVU has up to four 3 A Form C relays (SPDT) with multiple power loss fail-safe options. Relays can be configured for proper protective action upon input loop break. Relay ON and OFF delay times are user adjustable. Up to eight front panel indicators show alarm and/or relay state. All relays can be configured for 0-100% deadband. Relay Operation/Configuration There are powerful relay functions that can be configured in the PROVU meter, including: • Automatic reset only (non-latching) • Automatic + manual reset at any time (non-latching) • Latching (manual reset only) • Latching with clear (manual reset only after alarm condition has cleared)• Pump alternation control (automatic reset only) • Sampling (activated for a user-specified time) • User selectable fail-safe operation • Relay action for loss (break) of 4-20 mA input signal • Time delay (on and off), independent for each relay• Manual control mode • Interlock relay mode Analog Output The isolated analog retransmission signal can be configured to represent the process variable (PV), maximum (peak) value, minimum (valley) value, the value for any of the eight relay set points, or Modbus input. While the output is nominally 4-20 mA, the signal will accurately accommodate under- and over-ranges from 1 to 23 mA. Manual Output Control Take control of any output with this feature. All relays can be forced ON or OFF, and the 4-20 mA output signal can be set to any value within its range. When the relays and 4-20 mA output are controlled manually, an LED labeled “M” is turned on and the associated Alarm LEDs (1-8) flash every 10 seconds indicating that the meter is in manual control mode. Isolated Transmitter Power Supplies A powerful 24 V @ 200 mA power supply is a standard feature on the PROVU meter. It can be configured for 5, 10, or 24 V (default) by means of a simple internal jumper (see manual). An additional power supply (24 V @ 40 mA) is standard with the 4-20 mA output option. Sampling Function (PV Triggered Timed Relay) The sampling function allows the operator to set a set point for a “sampling” relay. When the PV reaches that set point, it will close that relay’s contacts for a preset period of time (0.1 to 5999.9 seconds). An example of its use may be for beer/ale fermentation. When the batch reaches a certain pH, the relay contacts would close and by some means (light, horn, etc.) alert someone to take a sample, or provide the trigger to automatically take a sample of the batch. The utility of this function can, of course, be expanded beyond sampling and be used whenever a timed relay output closure is required when the PV reaches a certain set point. Interlock Relay(s) This function allows a process to use one or more very low voltage input signals or simple switch contacts to control the state of one or more internal “interlock” relays. A violation (i.e. loss of input, open switch, or open circuit) forces one or more N/O interlock relay contacts to open. One input can be used in series with a number of interlock switches, or up to eight inputs can be required to force-on one (or more) internal interlock relays. Please see Application Note AN-1008 on our website for more information. Requires PDA1044 Digital I/O module or use of on-board digital input F4. SIGNAL INPUT CONDITIONING Non-linear input signals can be linearized with the PROVU’s simple to use round horizontal tank linearizer, or the PROVU’s powerful general purpose linearizer. Loop-PwrRemoteIndicator(Volume) 4-20 mA Out HiAlarm LoAlarm + - Relay 1 & 2 Linearized4-20 mA Out 4-20 mA Loop Poweredby the Meter4-20 mA Outputfrom Level Transmitter LevelTransmitter 8-Point Linearizer for Volume Round Horizontal Tank Signal Input Conditioner COMNO NC 4 36 5 2 1 +5V I1 1 2 115 VAC NEUTLOAD COMNO NC Interlock Contact (Digital Input)Control Relay Interlock Relay www.predig.com6 PD6001 PROVU® Analog Input Feet & Inches Meter 5 ControlRelay ControlRelay MainPump OFF12ON8 BackupPump ON OFF LevelTransmitter4-20 mA Signal HiAlarm LoAlarm Relay #1 trips the Low Level Alarm at 8 feet and resets at 12 feet. 4 ControlRelay ControlRelay MainPump ON48 OFF35 BackupPump ON ON LevelTransmitter4-20 mA Signal HiAlarm LoAlarm Relay #2 trips the High Level Alarm at 48 feet and resets at 35 feet. 3 ControlRelay ControlRelay MainPump ON45 OFF10 BackupPump ON ON LevelTransmitter4-20 mA Signal HiAlarm LoAlarm If the backup pump is not able to keep up, and the level reaches 45 feet, relay #4 transfers and starts the main pump as well. 2 ControlRelay ControlRelay MainPump ON40 OFF10 BackupPump OFF ON LevelTransmitter4-20 mA Signal HiAlarm LoAlarm With the Pump Alternation feature activated, the next time the level reaches 40 feet, relay #3 transfers and starts the backup pump. 1 ControlRelay ControlRelay MainPump ON40 OFF10 BackupPump ON OFF LevelTransmitter4-20 mA Signal HiAlarm LoAlarm Relay #4 turns the main pump on at 40 feet and turns it off at 10 feet. FT IN FT IN FT IN FT IN FT IN Level Level Level Level Level 8 8 8 8 8 42 11 01 43 01 01 45 07 03 48 01 01 7 11 07 Multi-Pump Alternation Up to 8 pumps can be alternated/sequenced. This not only provides a high level of control over the entire system, but also increases the life of your pumps. CONNECTIONS RI- I+ MA OUT 13 2 POWER +-SIGNAL M-LINK C NONO NC NC C RELAY4 RELAY3 4 36 5 2 1 C NONO NC NC C RELAY2 RELAY1 4 36 5 2 1 1 2 3 4 5 6 7 8 21 + 4-20 mA Output -+ Powered by PROVU 24 V • Form C (SPDT) relays• Two isolated supplies available even on 12/24 VDC input power models • Removable terminal blocks• 2 or 4 relays + isolated 4-20 mA output option • Input Power Options: 85-265 VAC or 12/24 VDC • Voltage or current inputs • No jumpers needed for V/mA input selection• M-Link for adding expansion modules • Digital input (F4) PROVU provides 24V@200 mA to power the transmitter - P- COMP+V+ mA+ 3 41 2 5 F4 6 PDA2811 Plastic Low-Cost NEMA 4 & 4X FIELD ENCLOSURES Precision Digital offers a variety of rugged enclosures that provide a high degree of protection against harsh operating environments. Thermoplastic and stainless steel NEMA 4X, and painted steel NEMA 4 enclosures for up to 10 PROVU meters are available. See our complete offering at www.predig.com/esu PDA2706 Steel PDA2812 Plastic Low-Cost PDA2302 Plastic Economical PDA3400 Plastic Internally Mounted PDA2600 Stainless Steel PROTEX-MAX EXPLOSION-PROOF All the proven features of the PROVU brought into your hazardous areas! Go to www.predig.com/pd8 PD8-6000 ProtEX-MAX Explosion-Proof www.predig.com7 PD6001 PROVU® Analog Input Feet & Inches Meter SPECIFICATIONSExcept where noted all specifications apply to operation at +25°C. General Display: Upper Feet & Inches display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs. Feet & Inches Display Range: 0' 00" 0/16" to 99' 11" 15/16" Display Intensity: Eight intensity levels Display Update Rate: 5/second (200 ms) Overrange: Display flashes 999999 Underrange: Display flashes -99999 Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max & min, set points, units (lower display only), or Modbus input. Front Panel: NEMA 4X, IP65 Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers. F4 Digital Input Contacts: 3.3 VDC on contact. Connect normally open contacts across F4 to COM. F4 Digital Input Logic Levels: Logic High: 3 to 5 VDC Logic Low: 0 to 1.25 VDC Noise filter: Programmable from 2 to 199 (0 will disable filter) Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months. Max/Min Display: Max / min readings reached by the process are stored until reset by the user or until power to the meter is turned off. Password: Three programmable passwords restrict modification of programmed settings. Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost. Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or optional model with 12-24 VDC ±10%, 15 W max. Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse. Isolated Transmitter Power Supply: Terminals P+ & P-: 24 VDC ± 10%. Internally selectable jumper for 24, 10, or 5 VDC supply. 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply. Normal Mode Rejection: Greater than 60 dB at 50/60 Hz Isolation: 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply. Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III. Environmental: Operating temperature range: -40 to 65°C Storage temperature range: -40 to 85°C Relative humidity: 0 to 90% non-condensing Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters. Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black Mounting: 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided. Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm) Dimensions: 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) weight: 9.5 oz (269 g) UL File Number: UL & C-UL Listed. E160849; 508 Industrial Control Equipment. warranty: 3 years parts & labor USB Connection: Compatibility: USB 2.0 Standard, Compliant Connector Type: Micro-B receptacle Cable: USB A Male to Micro-B Cable Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit Power: USB Port Process Input Inputs: Field selectable: 0-20, 4-20 mA, ±10 VDC (0-5, 1-5, 0-10 V), Modbus PV (Slave) Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span Temperature Drift: 0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient Signal Input Conditioning: Linear or round horizontal tank volume calculation. Multi-Point Linearization: 2 to 32 points for PV or PV1. 2 to 8 points for PV2 (Dual-Scale Level feature) Programmable Exponent: 1.0001 to 2.9999 Low-Flow Cutoff: 0-999999 (0 disables cutoff function) Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd. Calibration Range: 4-20 mA: minimum span input 1 & input 2: 0.15 mA. ±10 V: minimum span input 1 & 2: 0.10 V. An Error message will appear if input 1 and input 2 signals are too close together. Input Impedance: Voltage ranges: greater than 1 MΩ. Current ranges: 50 - 100 Ω (depending on resettable fuse impedance). Input Overload: Current input protected by resettable fuse, 30 VDC max. Fuse resets automatically after fault is removed. Relays Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (≈ 50 watts) @ 125/250 VAC for inductive loads such as contactors, solenoids, etc. Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads. Deadband: 0-100% of span, user programmable High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off). Relay Operation: automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode). Relay Reset: User selectable via front panel buttons or digital inputs. 1. Automatic reset only (non-latching), when input passes the reset point. 2. Automatic + manual reset at any time (non-latching). 3. Manual reset only, at any time (latching). 4. Manual reset only after alarm condition has cleared (latching). Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset. Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay. Fail-Safe Operation: Programmable and independent for each relay. Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state. Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter. Serial Communications Protocol: Modbus® RTU (Slave Only) Meter Address/Slave ID: 1 - 247 Baud Rate: 300 - 19,200 bps Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communication Data: 8 bit (1 start bit, 1 or 2 stop bits) Parity: Even, odd, or none with 1 or 2 stop bits Byte-to-Byte Timeout: 0.01 - 2.54 seconds Turn Around Delay: Less than 2 ms (fixed)Note: Refer to the PROVU® Register Tables located at www.predig.com for details. PD6001 PROVU® Analog Input Feet & Inches Meter www.predig.com LDS6001_C 05/16 Precision Digital corPoration 233 South Street • Hopkinton MA 01748 USA • Tel (800) 343-1001 • Fax (508) 655-8990 ORDERING INFORMATION PROVU® PD6001 • Standard Models 85-265 VAC Model 12-24 VDC Model Options Installed PD6001-6R0*PD6001-7R0 None PD6001-6R2* PD6001-7R2 2 Relays PD6001-6R3* PD6001-7R3 4-20 mA Output PD6001-6R4*PD6001-7R4 4 Relays PD6001-6R5* PD6001-7R5 2 Relays & 4-20 mA Output PD6001-6R7* PD6001-7R7 4 Relays & 4-20 mA Output Note: 24 V Transmitter power supply standard on all models.* Quick Shipment Program product, typically ships within 2 working days. PROVU® PD6001 • SunBright Display Models 85-265 VAC Model 12-24 VDC Model Options Installed PD6001-6H0 PD6001-7H0 None PD6001-6H2 PD6001-7H2 2 Relays PD6001-6H3 PD6001-7H3 4-20 mA Output PD6001-6H4 PD6001-7H4 4 Relays PD6001-6H5 PD6001-7H5 2 Relays & 4-20 mA Output PD6001-6H7 PD6001-7H7 4 Relays & 4-20 mA Output Note: 24 V Transmitter power supply standard on all models. Accessories Model Description PDA1002 DIN Rail Mounting Kit for Two Expansion Modules PDA1004 4-Relay Expansion Module PDA1044 4 Digital Inputs & 4 Digital Outputs Module PDA1232 RS-232 Serial Adapter PDA1485 RS-485 Serial Adapter PDA7485-I RS-232 to RS-422/485 Isolated Converter PDA7485-N RS-232 to RS-422/485 Non-Isolated Converter PDA8232-N USB to RS-232 Non-Isolated Converter PDA8485-I USB to RS-422/485 Isolated Converter PDA8485-N USB to RS-422/485 Non-Isolated Converter PDX6901 Suppressor (snubber): 0.01 μF/470 Ω, 250 VAC Disclaimer The information contained in this document is subject to change without notice. Precision Digital Corporation makes no representations or warranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. ©2014-2016 Precision Digital Corporation. All rights reserved. your Local Distributor is: Notes: 1. Panel cutout required: 1.772" x 3.622" (45 mm x 92 mm)2. Panel thickness: 0.040 - 0.250" (1.0 mm - 6.4 mm) 3. Mounting brackets lock in place for easy mounting4. Clearance: Allow 6" (152 mm) behind the panel Isolated 4-20 mA Transmitter Output Output Source: Process variable (PV), max, min, set points 1-8, manual control setting, or Modbus input Scaling Range: 1.000 to 23.000 mA for any display range Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output Analog Output Programming: 23.000 mA maximum for all parameters: Overrange, underrange, max, min, and break Accuracy: ± 0.1% of span ± 0.004 mA Temperature Drift: 0.4 μA/°C max from 0 to 65°C ambient, 0.8 μA/°C max from -40 to 0°C ambient Note: Analog output drift is separate from input drift. Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10%. Isolated from the input at >500 V. May be used to power the 4-20 mA output or other devices. All models rated @ 40 mA max. External Loop Power Supply: 35 VDC maximum Output Loop Resistance: Power supply Minimum Maximum 24 VDC 10 Ω 700 Ω 35 VDC (external) 100 Ω 1200 Ω DIMENSIONS 3.61" (91.5 mm) 4.17"(106 mm) 4.68"(119 mm) 1.76"(44.5 mm) 0.59"(15 mm)4.77" (121 mm) 2.45"(62 mm) (128 mm)5.05" Side View Top View 6" (152 mm) Clearance NO NCNCC NOCNONCNCCNOC+-ROptional Connectors Installed 3.61" (91.5 mm) 4.17"(106 mm) 4.68"(119 mm) 1.76" (44.5 mm) 0.59" (15 mm)4.77" (121 mm) 2.45"(62 mm) (128 mm) 5.05" Side View Top View 6" (152 mm) Clearance NO NCNCC NOCNONCNCCNOC+-ROptional Connectors Installed