HomeMy WebLinkAboutDERR-1991-014034 - 0901a06880540439DOE ID NO. : MS- QQOfcQ - ^ -S Property Address: 4 4-^ SooTV> /11a SrVeefj VICINITY PROPERTY CERTIFICATION SUMMARY AND RECOMMENDATION SUMMARY EVALUATION Chem-Nuclear Geotech, Inc. YES NO NOT TAKEN Ra-226 is < 5 pCi/g above background in top 15-cm layer of soil averaged over 100 m2. [X]* [ ] [ ] In-situ [X] Lab [ ] Ra-226 is < 15 pCi/g above background in any 15-cm layer of soil more than 15 cm below the surface averaged over 100 m2. M [ ] ( ] In-situ [ ] Lab £x] Interior gamma is < 20 pR/h above background in any occupied or habitable structure. [><] [ ] [ ] The radon decay-product concentration in any occupied or habitable structure is < 0.02 working levels or, at most, 0.03 working levels. [><] [ ] [ ] Supplemental standards were applied in accordance with EPA standard 40 CFR 192.21. [ ] [x] [ ] Hot spot criteria met as outlined by U.S. DOE guidelines for FUSRAP and Decontamination and Decommissioning [ ] [ ] Cx] Program (Rev. 03/02/87). U.S. Department of Energy (DOE) YES NO NOT TAKEN t ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ 1 [ ] [ ] [ ] [ ] [ ] [ ] COMMENTS: *The excavations were backfilled with materials which were measured at the source showing that the Ra-226 concentrations are in the range of normal background. Other surface areas were verified on the basis of gamma exposure rates which do not exceed 30-percent above normal background. SFCERTIFED SFMS-00068 SCANNED DFRR - iqqi-Qigong DOE ID NO. : MS- OOOG8~ CHEM-NUCLEAR GEOTECH, INC., RECOMMENDATION Based on the Chem-Nuclear Geotech, Inc., evaluation, I recommend this property for: [X] Certification by the Department of Energy. ( ] Certification by the Department of Energy with the concurrence of the Nuclear Regulatory Commission because supplemental standards were applied per 40 CFR 192.21. 7 Jarry Decontamination and Decommissioning Program Manager Chem-Nuclear Geotech, Inc. *////?/ Date DOE EVALUATION [>d Should be certified by the Department of Energy. [ ] Should be certified by the Department of Energy with the concurrence of the Nuclear Regulatory Commission because supplemental standards were applied per 40 CFR 192.21. Decontamination and Decommissioning Program Certification Official Department of Energy Date DOE ID NO. MS-00376 232 South 1st East Street VICINITY PROPERTY SUMMARY EVALUATION AND FINDINGS 1.0 SUMMARY EVALUATION 1.1 EXTERIOR MEASUREMENTS Inclusion Survey Chem-Nuclear Geotech Gamma is > 25 piR/h above background averaged over 100 m2 Yes [ ] No Not Taken* [X] [ ] Gamma is < the acceptable difference or < 20% above background averaged over [X] [ ] [ ] 100 m2 Radium-226 is > 5 pCi/g above background in top 15 cm layer averaged over [ ] [X] [ ] 100 m2 Radium-226 is > 15 pCi/g above background in any subsurface 15 cm layer [ ] [ ] [X] averaged over 100 m2 Radium-226 is > 'Hot Spot' Guidelines [ ] [X] [ ] 1.2 INTERIOR MEASUREMENTS Gamma is > 20 j/R/h above background averaged in [ ] [X] [ ] any room (9.3 m2) Gamma is < the acceptable difference or < 20% above [X] [ ] [ ] background in all rooms Annual average radon decay-product concentration [ ] [ ] [X] is < 0.02 working level U.S. Department of Energy (DOE) Yes No Not Taken* [ ] [ ] [ ] [ ] [ ] [ 3 [ ] t ] [ ] [ ] [ 1 [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] Other: * Data were not taken because: [X] Data were not required to derive the findings. [ ] Property owner did not authorize access for interior sampling. FIELD ASSESSMENTS SECTION REPORT OF INCLUSION/EXCLUSION FOR BLOCK 13, MS-09013-BK MONTICELLO, UTAH MS-00371, MS-00372, MS-00373, MS-00374, MS-00375, MS-00376, MS-00377, MS-00378, AND MS-00379 Submitted: February 15,1991 Prepared by CHEM-NUCLEAR GEOTECH, INC. Grand Junction Projects Office Grand Junction, Colorado 81502 for the U.S. DEPARTMENT OF ENERGY CONTENTS Report of Radiological Survey Property/Owner Information List of Formulas Tables by Property: Radiological Screening Survey Results - Exterior Screening Radiological Screening Survey Results - Interior Screening Extended Survey Results - Exterior Extended Data Appendix A - Radiological Assessment • DOE ID NO. MS-09013-BK REPORT OF RADIOLOGICAL SURVEY AT DOE ID NUMBER MS-09013-BK 1.0 INTRODUCTION A radiological screening survey of DOE ID number MS-09013-BK was conducted by Chem-Nuclear Geotech, Inc. This survey was conducted using methods, as defined in the Vicinity Properties Management and Implementation Manual, UMTRA-DOE/AL-050601 (March 1988), the U.S. Department of Energy (DOE) Guidelines for Residual Radioactive Material at Formerly Utilized Sites Remedial Action Program (FUSRAP), Revision 2, March 1987, and the Chem-Nuclear Geotech, Inc., Field Assessments Procedures Manual. In order to simplify and expedite the identification and removal of mill tailings from Monu'cello properties, the DOE is using a "block" concept for the inclusion surveys and for the cleanup work. All of the properties in a city block that had not been previously assessed were surveyed sequentially to ensure the properties with contamination in excess of the Environmental Protection Agency (EPA) standards were identified in a timely and cost effective manner. The radiological survey of this block included gamma scans of the entire ground surface (exterior and interior), samples of exterior soil, and evaluation of historical data when present An assessment was also performed on this block to determine the aerial and vertical extent of the contamination. The results are shown in the Appendix A. 2.0 SUMMARY OF RECOMMENDATIONS The following table lists the recommendation for inclusion or exclusion for each properly investigated in Block 13: MONTICELLO, UTAH 84535 DOE ID NUMBER ADDRESS RECOMMENDATION MS MS' MS MS MS MS. MS MS MS •00371 •00372 •00373 •00374 •00375 •00376 •00377 •00378 •00379 264 South 1st East Street 117 South Main Street 56 East 2nd South Street 20 East 2nd South Street 254 South 1st East Street 232 South 1st East Street 96 East 2nd South Street 80 East 2nd South Street 64 East 2nd South Street Exclusion Exclusion Exclusion Exclusion Inclusion Exclusion Exclusion Exclusion Exclusion -1- DOE ID NO. MS-09013-BK 3.0 RESULTS AND CONCLUSIONS DOE ID NUMBER MS-00372 117 South Main Street Monticello, Utah 84535 The exterior background gamma exposure rate is 15 uR/h; the interior background gamma exposure rate for the multi-level brick building is 15 uR/h. Gamma exposure rates are shown in Figure 1, Appendix A. No exterior elevated gamma exposure rates were found; however, background soil samples were collected at Location Numbers 4, 5, 6, and 9 (Figure 1, Appendix A). The results of the soil samples are shown in Table lb, Appendix A. DOE ID Number MS-00372 Site contains radiation levels which DO NOT EXCEED the DOE guidelines below: Recommend: Exclusion Exterior gamma exposure rate is less than the acceptable difference or less than 20% above background averaged over 100 m2. Radium-226 is less than 5.0 pCi/g above background in the surface 15-cm soil layer averaged over 100 m2. DOE ID NUMBER MS-00374 20 East 2nd South Street Monticello, Utah 84535 The exterior background gamma exposure rate is 15 uR/h; the interior background gamma exposure rate for the single-story brick building is 14 |iR/h. Gamma exposure rates are shown in Figure 1, Appendix A. No exterior elevated exposure rates were found; however, a background soil sample was collected at Location Number 11 (Figure 1, Appendix A). The result of the soil sample is shown in Table Ic, Appendix A. DOE ID Number MS-00374 Site contains radiation levels which DO NOT EXCEED the DOE guidelines below: Recommend: Exclusion Exterior gamma exposure rate is less than the acceptable difference or less than 20% above background averaged over 100 m2. Radium-226 is less than 5.0 pCi/g above background in the surface 15-cm soil layer averaged over 100 m2. -2- • DOE ID NO. MS-09013-BK DOE ID NUMBER MS-00373 56 East 2nd South Street Monticello, Utah 84535 The exterior background gamma exposure rate is 15 tiR/h; the interior background gamma exposure rate for the two-story block building is 14 \<R/h. Two regions of exterior elevated gamma exposure rates were found and labeled Regions 1 and 2 (Figure 1, Appendix A). The soil samples collected from Regions 1 and 2 (Location Numbers 13, 14, and 15, Figure 1, Appendix A) yielded net area-weighted average radium-226 concentrations of less than 1.0 pCi/g. This value is less than the EPA guidelines of 5.0 pCi/g above background for surface soil. The results of the soil samples are shown in Table Id, Appendix A. DOE ID Number MS-00373 Site contains radiation levels which DO NOT EXCEED the DOE guidelines below: Recommend: Exclusion Radium-226 is less than 5.0 pCi/g above background in the surface 15-cm soil layer averaged over 100 m2. DOE ID NUMBER MS-00379 64 East 2nd South Street Monticello, Utah 84535 The exterior background gamma exposure rate is 14 uR/h; the interior background gamma exposure rate for the single-story block building is 15 uR/h. Two regions of exterior elevated gamma exposure rates were found and labeled Regions 2 and 3 (Figure 1, Appendix A). The soil samples collected from Regions 2 and 3 (Location Numbers 16 and 17, Figure 1, Appendix A) each yielded a net area-weighted average radium-226 concentration of less than 1.0 pCi/g. This value is less than the EPA guidelines of 5.0 pCi/g above background for surface soil. The results of the soil samples are shown in Table le, Appendix A. Site contains radiation levels which DO NOT EXCEED the DOE guidelines below: Exterior gamma exposure rate is less than the acceptable difference or less than 20% above background averaged over 100 m2. Radium-226 is less than 5.0 pCi/g above background in the surface 15-cm soil layer averaged over 100 m2. DOE ID Number MS-00379 Recommend: Exclusion -3- • DOE ID NO. MS-09013-BK DOE ID NUMBER MS-00375 254 South 1st East Street Monticello, Utah 84535 The exterior background gamma exposure rate is 15 jiR/h. There were no habitable structures on this property. Two regions of exterior elevated gamma exposure rates were found and labeled Regions 4 and 5 (Figure 1, Appendix A). The soil samples collected from Regions 4 and 5 (Location Numbers 19 and 21, Figure 1, Appendix A) each yielded a net area-weighted average radium-226 concentration of 1.3pCi/g and less than 1.0 pCi/g, respectively. These values are less than the EPA guidelines of 5.0 pCi/g above background for surface soil. However, the soil sample from Region 4 resulted in a net radium-226 concentration of 129.6 pCi/g which exceeds the surface 'Hot Spot' Guideline of 50.0 pCi/g for a 1.0 m2 area. The results of the soil samples are shown in Table If, Appendix A. DOE ID Number MS-00375 Site contains radiation levels which EXCEED the DOE guidelines below: Recommend: Inclusion Radium-226 exceeds the 'Hot Spot' Guidelines. DOE ID NUMBER MS-00378 80 East 2nd South Street Monticello, Utah 84535 The exterior background gamma exposure rate is 15 uR/h; the interior background gamma exposure rate for the two-story frame house is 15 uR/h. Gamma exposure rates are shown in Figure 1, Appendix A. No exterior elevated gamma exposure rates were found; however, two background soil samples were collected at Location Numbers 22 and 23 (Figure 1, Appendix A). The results of the soil samples are shown in Table Ig, Appendix A. DOE ID Number MS-00378 Site contains radiation levels which DO NOT EXCEED the DOE guidelines below: Recommend: Exclusion Exterior gamma exposure rate is less than the acceptable difference or less than 20% above background averaged over 100 m2. Radium-226 is less than 5.0 pCi/g above background in the surface 15-cm soil layer averaged over 100 m2. -4- DOE ID NO. MS-09013-BK DOE ID NUMBER MS-00371 264 South 1st East Street Monticello, Utah 84535 The exterior background gamma exposure rate is 16 piR/h; the interior background gamma exposure rate for the single-story brick building is 15 uR/h. Two regions of exterior elevated gamma exposure rates were found and labeled Regions 6 and 7 (Figure 1, Appendix A). The soil samples collected from Regions 6 and 7 (Location Numbers 25 and 27, Figure 1, Appendix A) each yielded a net area-weighted average radium-226 concentration of less than 1.0 pCi/g. This value is less than the EPA guidelines of 5.0 pCi/g above background for surface soil. The results of the soil samples are shown in Table lh. Appendix A. DOE ID Number MS-00371 Site contains radiation levels which DO NOT EXCEED the DOE guidelines below: Recommend: Exclusion Exterior gamma exposure rate is less than the acceptable difference or less than 20% above background averaged over 100 m2. Radium-226 is less than 5.0 pCi/g above background in the surface 15-cm soil layer averaged over 100 m2. DOE ID NUMBER MS-00376 232 South 1st East Street Monticello, Utah 84535 The exterior background gamma exposure rate is 15 uR/h; the interior background gamma exposure rate for the two-story metal and stucco building is 13 |iR/h. Gamma exposure rates are shown in Figure 1, Appendix A. No exterior elevated gamma exposure rates were found; however two background soil samples were collected at Location Numbers 28 and 29 (Figure 1, Appendix A). The results of the soil samples are shown in Table li, Appendix A. I I l -5- DOE ID NO. MS-09013-BK DOE ID Number MS-00376 Site contains radiation levels which DO NOT EXCEED the DOE guidelines below: Recommend: Exclusion Exterior gamma exposure rate is less than the acceptable difference or less than 20% above background averaged over 100 m2. Radium-226 is less than 5.0 pCi/g above background in the surface 15-cm soil layer averaged over 100 m2. DOE ID NUMBER MS-00377 96 East 2nd South Street Monticello, Utah 84535 The exterior background gamma exposure rate is 16 uJR/h; the interior background gamma exposure rate for the two-story brick and stucco building is 14 |iR/h. Gamma exposure rates are shown in Figure 1, Appendix A. No exterior elevated gamma exposure rales were found; however, two background soil samples were collected at Location Numbers 30 and 31 (Figure 1, Appendix A). The results of the soil samples are shown in Table lj, Appendix A. DOE ID Number MS-00377 Site contains radiation levels which DO NOT EXCEED the DOE guidelines below: Recommend: Exclusion Exterior gamma exposure rate is less than the acceptable difference or less than 20% above background averaged over 100 m2. Radium-226 is less than 5.0 pCi/g above background in the surface 15-cm soil layer averaged over 100 m2. -6- PROPERTY/OWNER INFORMATION BLOCK 13, MONTICELLO, UTAH Page 1 of 5 DOE ID NUMBER: MS-00372 PROPERTY LOCATION: PROPERTY OWNER: OWNER ADDRESS: TELEPHONE NUMBER: OCCUPANT/TENANT: TELEPHONE NUMBER: 117 South Main Street, Monticello, Utah San Juan County Same (801) 587-2237 Same Same PROPERTY CLASSIFICATION: Jail TOTAL AREA OF PROPERTY: 11,247 m2 STRUCTURES ON PROPERTY: A multi-level brick building . 4 IT MS-00372 Looking northeast MS-00374 Looking southeast DOE ID NUMBER: MS-00374 PROPERTY LOCATION: PROPERTY OWNER: OWNER ADDRESS: TELEPHONE NUMBER: OCCUPANT/TENANT: TELEPHONE NUMBER: 20 East 2nd South Street, Monticello, Utah None None PROPERTY CLASSIFICATION: Commercial Structure TOTAL AREA OF PROPERTY: 112 m2- STRUCTURES ON PROPERTY: A single-story brick building PROPERTY/OWNER INFORMATION BLOCK 13, MONTICELLO, UTAH Page 2 of 5 DOE ID NUMBER: MS-00373 PROPERTY LOCATION: 56 East 2nd South Street, Monucello, Utah PROPERTY OWNER: OCCUPANT/TENANT: None TELEPHONE NUMBER: None PROPERTY CLASSIFICATION: Commercial Structure TOTAL AREA OF PROPERTY: 1,015 m2 STRUCTURES ON PROPERTY: A two-story block building MS-00373 East side of Block Building Looking south MS-00373 West side of Block Building Looking south PROPERTY/OWNER INFORMATION BLOCK 13, MONTICELLO, UTAH Page 3 of 5 DOE ID NUMBER: MS-00379 PROPERTY LOCATION: PROPERTY OWNER: OWNER ADDRESS: TELEPHONE NUMBERS: OCCUPANT/TENANT: TELEPHONE NUMBER: PROPERTY CLASSIFICATION: TOTAL AREA OF PROPERTY: STRUCTURES ON PROPERTY: 64 East 2nd South Street Commercial Structure 798 m2 A single-story block building as* ,.•.,.<»«•.•«...... i asa« • — s . »j! 1" SK9S IK*! MS-00379 Looking south MS-00375 Looking west DOE ID NUMBER: MS-00375 PROPERTY LOCATION: PROPERTY OWNER: OWNER ADDRESS: TELEPHONE NUMBER: OCCUPANT/TENANT: TELEPHONE NUMBER: PROPERTY CLASSIFICATION: Vacant Lot TOTAL AREA OF PROPERTY: 1,296 m2 STRUCTURES ON PROPERTY: None 254 South 1st East Street, Monticello, Utah Vacant Lot N/A PROPERTY/OWNER INFORMATION BLOCK 13, MONTICELLO, UTAH Pase 4 of 5 DOE ID NUMBER: MS-00378 80 East 2nd South Street, Monticello, Utah None None PROPERTY LOCATION: PROPERTY OWNER: OWNER ADDRESS: TELEPHONE NUMBER: OCCUPANT/TENANT: TELEPHONE NUMBER: PROPERTY CLASSIFICATION: Residence TOTAL AREA OF PROPERTY: 1,252 m2 STRUCTURES ON PROPERTY: A two-story frame house and a frame shed Sis*™ MS-00378 Looking southwest MS-00371 Looking southwest DOE ID NUMBER: MS-00371 PROPERTY LOCATION: PROPERTY OWNER: OWNER ADDRESS: TELEPHONE NUMBER: OCCUPANT/TENANT: TELEPHONE NUMBER: 264 South 1st East Street, Monticello, Utah None None PROPERTY CLASSIFICATION: Commercial Structure TOTAL AREA OF PROPERTY: 1,645 m2 STRUCTURES ON PROPERTY: A single-story brick building PROPERTY/OWNER INFORMATION BLOCK 13, MONTICELLO, UTAH Page 5 of 5 DOE ID NUMBER: MS-00376 232 Souih 1st East Street, Monticello, Utah None None PROPERTY LOCATION: PROPERTY OWNER: OWNER ADDRESS: TELEPHONE NUMBER: OCCUPANT/TENANT: TELEPHONE NUMBER: PROPERTY CLASSIFICATION: Apartment TOTAL .AREA OF PROPERTY: 295 m2 STRUCTURES ON PROPERTY: A two-story metal and stucco building 2$ MS-00376 Looking west MS-00377 Looking south DOE ID NUMBER: MS-00377 PROPERTY LOCATION: PROPERTY OWNER: OWNER ADDRESS: TELEPHONE NUMBER: OCCUPANT/TENANT: TELEPHONE NUMBER: 96 East 2nd South Street, Monticello, Utah None None PROPERTY CLASSIFICATION: Apartment TOTAL AREA OF PROPERTY: 342 m* STRUCTURES ON PROPERTY: A two-story brick and stucco building LIST OF FORMULAS Page 1 of 1 The following is list of forumlas used in the tables for each property. : Formula used to calculate the net estimated area-weighted average gamma exposure rate for exterior screening: GAW = the area-weighted average gamma exposure rate (uR/h) G; = a series of average gamma exposure rates less background (tiR/h) Ai = a series of areas within regions of contamination (m2) 100 = threshold area (m2) Formula used to calculate the net estimated area-weighted average gamma expsoure rate for interior screening: G^, = the area-weighted average gamma exposure rate QiR/h) Gj = a series of average gamma exposure rates less background (pR/h) Ai = a series of areas within regions of contamination (m2) 9.3 = threshold area (m2) Formula used to calculate the net estimated area-weighted average radium-226 concentration in soil (pCi/g): Cxw = the area-weighted average radium-226 concentration (pCi/g) Ci = a series of average radium-226 concentrations less background (pCi/g) Ai = a series of areas within regions of contamination (m2) D;. = a series of depths of samples (m) 100 = the area used in averaging (m2) 0.15 = the depth of sample used in averaging (m) Formula used to calculate the Hot Spot Guideline: 100 mz HSL = the Hot Spot Guideline Limit (pCi/g) Cm = the maximum allowable radium concentration for this site (5.0 pCi/g for surface soil and 15.0 pCi/g for subsurface soil) A = the area of the Hot Spot (m2) Block 13 DOE ID NUMBER MS-00372 117 South Main Street Monticello, Utah 84535 Page 1 of 9 RADIOLOGICAL SCREENING SURVEY RESULTS EXTERIOR SCREENING MEAN BACKGROUND EXPOSURE RATE: 15uR/h BACKGROUND PLUS 20 PERCENT: 18 jiR/h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: None REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: General 15 n-R/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: Om2 NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: 0u.R/h RADIOLOGICAL SCREENING SURVEY RESULTSi 7 STRUCTURE DESCRIPTION OR NUMBER: Multi-Level Brick Building MEAN BACKGROUND EXPOSURE RATE: 15 u.R/h BACKGROUND PLUS 20 PERCENT: 18 uR/h REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: General 15 u.R/h POINT SOURCES (Discussed in Section 3.0): None NET ESTIMATED AREA-WEIGHTED AVERAGE: 0u.R/h 111 RADto SAMPLE LOCATION NUMBER: REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm): 15 RADIUM-226 CONCENTRATION (pCi/g): 1.4 2.1 2.1 1.4 REPRESENTATIVE (biased) SAMPLING AREA (m2): >100 NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi/g): N/A HOT SPOT GUIDELINE (pCi/g): N/A • Block 13 DOE ID NUMBER MS-00374 20 East 2nd South Street Monticello, Utah 84535 Page 2 of 9 RADIOLOGICAL1 SCREENING SURVEY RESULTS J ; EXTERIOR SCREENING MEAN BACKGROUND EXPOSURE RATE: 15 u.R7h BACKGROUND PLUS 20 PERCENT: 18 uR/h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: None REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: General 15u,R/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: 0 m2 NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: 0 U-R/h RADIOLOGICAL SCREENING SURVEY RESULTS ^ : INTERIOR SCREENING ^ STRUCTURE DESCRIPTION OR NUMBER: Single-Story Brick Building MEAN BACKGROUND EXPOSURE RATE: 14 uR/h BACKGROUND PLUS 20 PERCENT: 17u.R/h REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: General 15jiR/h POINT SOURCES (Discussed in Section 3.0): None NET ESTIMATED AREA-WEIGHTED AVERAGE: 0 u.R/h • RADIOLC^CALSCREENINGSURVEY RESULTS-M SAMPLE LOCATION NUMBER: 11 REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm): 15 RADIUM-226 CONCENTRATION (pCi/g): 1.5 REPRESENTATIVE (biased) SAMPLING AREA (m2): >100 NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi/g): N/A HOT SPOT GUIDELINE (pCi/g): N/A • DOE ID NUMBER MS-00373 56 East 2nd South Street Block 13 Monticello, Utah 84535 Page 3 of 9 RADIOLOGICAL SCREENING SURVEY RESULTS ^ ;M::Ji;: EXTERIOR SCREENING ? v : MEAN BACKGROUND EXPOSURE RATE: 15 M-R/h BACKGROUND PLUS 20 PERCENT: 18uR/h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: Region 1 Region 2 18 u.R/h 18-21 uR/h REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: Region 2 21 uR/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: Region 1 Region 2 2.8 nf 20.7 m2 NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: Region 1 <1 n-R/h Region 2 6u.R/h ! RADIOLOGICAL SCREENING SURVEY RESULTS STRUCTURE DESCRIPTION OR NUMBER: Two-Story Block Building MEAN BACKGROUND EXPOSURE RATE: 14uR/h BACKGROUND PLUS 20 PERCENT: 17u.R/h REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: General 16u.R/h POINT SOURCES (Discussed in Section 3.0): None NET ESTIMATED AREA-WEIGHTED AVERAGE: 0u.Fl/h ;^ RADIOLOGICAL SCREENING SURVEY RESULTS EXTERIOR EXTEND ED 'DATA * SAMPLE LOCATION NUMBER: 13 14 15 12 REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm): 15 RADIUM-226 CONCENTRATION (pCi/g): 1.5 1.2 2.7 1.4 REPRESENTATIVE (biased) SAMPLING AREA (m2): 2.8 20.7 N/A NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi/g): <1.0 N/A HOT SPOT GUIDELINE (pCi/g): N/A Block 13 DOE ID NUMBER MS-00379 64 East 2nd South Street Monticello, Utah 84535 Page 4 of 9 RADIOLO^CAL SCREENING SURVEY RESULTS: ? MEAN BACKGROUND EXPOSURE RATE: 14 uR/h BACKGROUND PLUS 20 PERCENT: 17uR/h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: Region 2 Region 3 18-21 uR/h 63 u.R/h REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: Region 3 63 uR/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: Region 2 Region 3 9.8 m2 < 1.0 m2 NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: Region 2 < 1 uR/h Region 3 < 1 u,R/h yNTERICfl SCREENING! STRUCTURE DESCRIPTION OR NUMBER: Single-Story Block Building MEAN BACKGROUND EXPOSURE RATE: 15u.R/h BACKGROUND PLUS 20 PERCENT: 18u.R/h REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: General 17u.R/h POINT SOURCES (Discussed in Section 3.0): None NET ESTIMATED AREA-WEIGHTED AVERAGE: 0u.R/h EXTENDED SURVEY RESULTS; EXTERIOR EXTENDED DATA SAMPLE LOCATION NUMBER: 16 17 18 REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm): 15 RADIUM-226 CONCENTRATION (pCi/g): 1.9 32.3 1.4 REPRESENTATIVE (biased) SAMPLING AREA (m2): 9.8 <1.0 N/A NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi/g): <1.0 N/A HOT SPOT GUIDELINE (pCi/g): N/A Block 13 DOE ID NUMBER MS-00375 254 South 1st East Street Monticello, Utah 84535 Page 5 of 9 EXTERIOR SCREENING MEAN BACKGROUND EXPOSURE RATE: 15 uR/h BACKGROUND PLUS 20 PERCENT: 18 uR/h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: Region 4 Region 5 18-44 uR'h 18 uR/h REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: Region 4 44 uR/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: Region 4 Region 5 < 1.0 m2 < 1.0 m2 NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: Region 4 Region 5 < 1 u.R/h < 1 u.R/h RADIOLOGICAL SCREENING SURVEY RESULTS 111111M STRUCTURE DESCRIPTION OR NUMBER: Vacant Lot MEAN BACKGROUND EXPOSURE RATE: N/A BACKGROUND PLUS 20 PERCENT: N/A REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: N/A POINT SOURCES (Discussed in Section 3.0): N/A NET ESTIMATED AREA-WEIGHTED AVERAGE: N/A •EXTENDED SURVEYRESULTS-i 1 EXTEfflOR EXtEN0ED;DATA« SAMPLE LOCATION NUMBER: 19 21 20 REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm) 15 RADIUM-226 CONCENTRATION (pCi/g): 131.6 5.1 3.3 REPRESENTATIVE (biased) SAMPLING AREA (m2): <1.0 >100 NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi/g): 1.3 <1.0 N/A HOT SPOT GUIDELINE (pCi/g): 50.0 N/A Block 13 DOE ID NUMBER MS-00378 80 East 2nd South Street Monticello, Utah 84535 Page 6 of 9 RADIOLOGICAL SCREENING SURVEY RESULTS ;7 !r : ^ErtOH SCREENING MEAN BACKGROUND EXPOSURE RATE: 15 uR/h BACKGROUND PLUS 20 PERCENT: 18u.R'h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: None REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: General 15 p.Fi/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: Onf NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: 0 u.R/h RADIOLOGICAL SCREENING SURVEY RESULTS:: ::i/INTERIOR SCREENING/ STRUCTURE DESCRIPTION OR NUMBER: Two-Story Frame House MEAN BACKGROUND EXPOSURE RATE: 15u.R/h BACKGROUND PLUS 20 PERCENT: 18u\R/h REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: General 16u.R/h POINT SOURCES (Discussed in Section 3.0): None NET ESTIMATED AREA-WEIGHTED AVERAGE: 0|iR/ri vEXTENbED^SORVEY; RESULTS K EXTERIOR-EnENDEb DATA): SAMPLE LOCATION NUMBER: 22 23 REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm): 15 RADIUM-226 CONCENTRATION (pCi/g): 3.2 2.8 REPRESENTATIVE (biased) SAMPLING AREA (nf): >100 NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi/g): N/A HOT SPOT GUIDELINE (pCi/g): N/A Block 13 DOE ID NUMBER MS-00371 264 South 1st East Street Monticello, Utah 84535 Page 7 of 9 EXTERIOR SCREENING: MEAN BACKGROUND EXPOSURE RATE: 16 jxR/h BACKGROUND PLUS 20 PERCENT: 19 u.R'h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: Region 6 Region 7 18-37 uR/h 18uR/h REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: Region 6 37 uR/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: Region 6 Region 7 2.5 m2 1.5 m2 NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: Region 6 Region 7 <1 u.R/h <1 u.R/h ; RADIOLOGIC*!! SCREENING SURVEY RESULTS liiii^ STRUCTURE DESCRIPTION OR NUMBER: Single-Story Brick Building MEAN BACKGROUND EXPOSURE RATE: 15 u,R/h BACKGROUND PLUS 20 PERCENT: 19u.R/h REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: General 16u.R/h POINT SOURCES (Discussed in Section 3.0): None NET ESTIMATED AREA-WEIGHTED AVERAGE: 0 u.R/h ii: EXTENDED SURVEY: RESULTS! aE^fflOREXTENDED DATA:1! SAMPLE LOCATION NUMBER: 25 27 26 REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm): 15 RADIUM-226 CONCENTRATION (pCi/g): 4.1 2.5 3.0 REPRESENTATIVE (biased) SAMPLING AREA (m2): 2.5 1.5 >100 NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi/g): <1.0 N/A HOT SPOT GUIDELINE (pCi/g): N/A • Block 13 DOE ID NUMBER MS-00376 232 South 1st East Street Monticello, Utah 84535 Page 8 of 9 RADIOLOGICAL SCREENING SURVEY RESULTS: L ; ; EXTERIOR SCRE MEAN BACKGROUND EXPOSURE RATE: 15 jxR/h BACKGROUND PLUS 20 PERCENT: 18 uR/h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: None REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: General 15 jxR/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: Onf NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: OuR/h :: RADIOLOGICAL SCREENING:SURVEY RESULTS;: STRUCTURE DESCRIPTION OR NUMBER: Two-Story Metal and Stucco Building MEAN BACKGROUND EXPOSURE RATE: 13u.R/h BACKGROUND PLUS 20 PERCENT: 16u,R/h REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: General 14 u.R/h POINT SOURCES (Discussed in Section 3.0): None NET ESTIMATED AREA-WEIGHTED AVERAGE: OuR/h /EXTENDED SURVEyiRESULtS;: ! EXTERIOR EXTENDED DATA/ SAMPLE LOCATION NUMBER: 28 29 REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm): 15 RADIUM-226 CONCENTRATION (pCi/g): 3.4 1.6 REPRESENTATIVE (biased) SAMPLING AREA (nf): >100 NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi/g): N/A HOT SPOT GUIDELINE (pCi/g): N/A Block 13 DOE ID NUMBER MS-00377 96 East 2nd South Street Monticello, Utah 84535 Page 9 of 9 - EXTERIOR SCREENING ; MEAN BACKGROUND EXPOSURE RATE: 17uR/h BACKGROUND PLUS 20 PERCENT: 20 uR/h EXPOSURE-RATE RANGE IN CONTAMINATED REGIONS: None REGION OF HIGHEST EXTERIOR GAMMA EXPOSURE RATE: General 17 u.R/h POINT SOURCES (Discussed in Section 3.0): None ESTIMATED AREA OF EXTERIOR CONTAMINATION BY REGION: Onf NET ESTIMATED AREA-WEIGHTED AVERAGE BY REGION: 0u.R/h RADIOLOGICAL SCREENING SURVEY RESULTS//: ||||||» STRUCTURE DESCRIPTION OR NUMBER: Two-Story Brick and Stucco Building MEAN BACKGROUND EXPOSURE RATE: 14u.R/h BACKGROUND PLUS 20 PERCENT: 17u.R/h REGION OF HIGHEST INTERIOR GAMMA EXPOSURE RATE: General 15 jiR/h POINT SOURCES (Discussed in Section 3.0): None NET ESTIMATED AREA-WEIGHTED AVERAGE: 0u,R/h EXTENDED SURVEY RESULTS £ EXTERIOR EXTENDED^ DAT A/' SAMPLE LOCATION NUMBER: 30 31 REGION SAMPLED: Bkgrd SAMPLE DEPTH (cm): 15 RADIUM-226 CONCENTRATION (pCi/g): 5.0 4.6 REPRESENTATIVE (biased) SAMPLING AREA (m2): >100 NET ESTIMATED AREA-WEIGHTED AVERAGE (pCi'g): N/A HOT SPOT GUIDELINE (pCi/g): N/A