Loading...
HomeMy WebLinkAboutDAQ-2024-008631 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-583-24 Site ID 11941 (B1) Olivia Cramm Ames Construction, Inc. 3737 West 2100 South West Valley City, UT 84120 Dear Ms. Cramm: Re: Ames Construction, Inc. – Temporary Relocation/Operation, Notice of Intent – Utah County Your Notice of Intent dated June 12, 2024, to relocate portable concrete batch plant equipment to the temporary project located from Redwood Road to the top of Hudson Road, Lehi, UT, received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: Erie Strayer F-10155 concrete batch plant and mixer Associated aggregate conveyor, bin, cement silo, Carrier refrigerating unit, and dust collector Three storage tanks Approval is subject to the conditions of the dust control plan submitted for this location and the current Ames Construction portable Approval Order (AO) DAQE-AN119410013-22, dated September 26, 2022. Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The operational days per site cannot be extended beyond the stipulated 365 consecutive day period. Hours of operation shall be held to 16 hours per each 24-hour day. As per Condition II.B.3.c of the above portable AO, the referenced equipment shall only operate between 6:00 AM and 10:00 PM each day. The maximum production rate shall be held to the requested 300 cubic yards per hour. The DAQ does not currently estimate emissions for temporary concrete batch plant operations. 2 + " Û Þ Û Ù Û Ý DAQC-583-24 Page 2 The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the Director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385)306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SPW:jl Enclosure: Submitted Temporary Relocation Form cc: Utah County Health Department 4 * - - $ . — 0 ) A @ v A ? A C @ F w B ? ˜ Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Wed, Jun 12, 2024 at 3:18 PM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Ames Construction has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2024-06-12 15:18:23 MDT IP: 205.182.133.105 ResponseID: R_3MfIqt1QDy2AUBE Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/ zel69R5w2OLh7a3jG8BTb35FN8n6gilDwv-8IuBWT3z3RsOaaCziGk2HGWKaYKKqs uEogLPpZKEX11xbcZ82KGof2T02B4vw-KqdB4LbXi4ACSfWU4Hzbum6LxNwH2cy3JJxm7zERbtdlgXnKWw7AuKlXi2YQ XcMma35Wpj07nfR-wkyC57jrNExl4IQ8CHUCgrGiwWIvm4ChGqm5nKLM0egtS2fBMxXcC4UF6e2l 3RUj6cveg65VaK8M3nDrR0DAdMsOqXTiYkrxKgTA9nKoZ8LhXTLiZNhMmvaZfI8FDFo3hbl8Ajpd-8rv5aWX1jaR3% 2EYz27HCV2VWJpais9njQ Response Summary: Please fill out the information below: Contact Person: Olivia Cramm Company Name: Ames Construction Mailing Address: 3737 West 2100 South City: Salt Lake City Zip: 84120 Phone Number: 8019778012 Email: Oliviacramm@amesco.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... Yes All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... 535329909C Briefly give directions to the site and/or physical address: Redwood Road to Hudson Way, take Hudson Way to top of road Proposed Relocation Information: Closest City Lehi County Utah UTM X Coordinates 578900.80 UTM Y Coordinates 4474389.17 Approximate distance to the nearest house/business .06 UTM X Coordinates to nearest house/business 578900.15 UTM Y Coordinates to nearest house/business 44744550.77 Does this site currently have a permit with DAQ? 6/14/24, 1:58 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1801691717702078823%7Cmsg-f:1801691717702078823&…1/3 No Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) DAQE-AN119410013-22 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Storage Tank Make/Model SP 55-4100 Dragon Serial or ID# 191087 Manufactured Date 1/1/23 Design Capacity 4100 cf 2 Equipment Type Storage Tank Make/Model SP 55-4100 Dragon Serial or ID# 191166 Manufactured Date 1/1/23 Design Capacity 4100 cf 3 Equipment Type Storage Tank Make/Model Central Tank Of OK Serial or ID# CSP 02 071 Manufactured Date 1/1/11 Design Capacity 4100 cf 4 Equipment Type Plant Mixer Make/Model Erie Strayer Serial or ID# F-10155 Manufactured Date 1/21/03 Design Capacity 4100 cy 5 Equipment Type Aggregate Conveyor Make/Model Erie Strayer Serial or ID# 5328 Manufactured Date 1/1/11 Design Capacity 3950 ton/hr 6 Equipment Type Cement Silo Make/Model Erie Strayer Serial or ID# 1-11937 Manufactured Date 1/1/11 Design Capacity 2866 cf 7 Equipment Type Aggregate Bin Make/Model Erie Strayer Serial or ID# 1-14255 Manufactured Date 1/11/11 Design Capacity 50 cy 8 Equipment Type Refrigerating Make/Model Carrier Serial or ID# 1722W93710 Manufactured Date 4/23/22 Design Capacity 82 lbs 9 Equipment Type Dust Collector Make/Model C&W MFG & Sales Co. Serial or ID# 26219 Manufactured Date 1/11/11 Design Capacity 13000 acfm Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3hrx3g5zDgpAyr6 Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... 6/14/24, 1:58 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1801691717702078823%7Cmsg-f:1801691717702078823&…2/3 No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 16 Starting time of operation (am/pm) 6 Ending time of operation (am/pm) 9 Maximum hourly production rate for project 300 cy/hr Expected startup date 07/01/2024 Expected completion date 02/15/2025 What type of application is this for? New Application In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2Vs97OVie7sUzcE Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3qqHgJIoEklnYmh 6/14/24, 1:58 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1801691717702078823%7Cmsg-f:1801691717702078823&…3/3 Susan Weisenberg <sweisenberg@utah.gov> RE: [EXTERNAL] generator question for batch relocation to Lehi 1 message Olivia Cramm <OliviaCramm@amesco.com>Thu, Jun 13, 2024 at 8:19 AM To: Susan Weisenberg <sweisenberg@utah.gov> The plant will be powered by temporary power connection. Olivia Cramm, CPESC, CISEC, QSP/QSD Region Environmental Manager OliviaCramm@amesco.com Mobile: 385-910-1481 Western: 801-977-8012 3737 West 2100 South West Valley City Utah 84120 AmesConstruction.com Instilling True Confidence. Delivering Success. The information transmitted is intended only for the person or entity to which it is addressed and may contain proprietary, business-confidential and/or privileged material. If you are not the intended recipient of this message you are hereby notified that any use, review, retransmission, dissemination, publication, distribution, reproduction or any action taken in reliance upon this message is prohibited. If you received this in error, please contact the sender and delete the material. Any views expressed in this message are those of the individual sender and may not necessarily reflect the views of the company. From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Wednesday, June 12, 2024 5:58 PM To: Olivia Cramm <OliviaCramm@amesco.com> Subject: [EXTERNAL] generator question for batch relocation to Lehi CAUTION: This email originated from outside of Ames Construction. DO NOT click links or open attachments unless you recognize and/or trust the sender. Contact Ames IT with questions or concerns. Hello, I always have to determinie if temporary projects will be powered by a diesel engine. Please let me know if there is an engine and what the size is, or let me know if this project will be connected to line power. Thanks Susan Weisenberg, Environmental Scientist Office: 385-306-6512 6/14/24, 1:43 PM State of Utah Mail - RE: [EXTERNAL] generator question for batch relocation to Lehi https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r6925194478135606974%7Cmsg-f:1801755931078645183…1/2 6/14/24, 1:43 PM State of Utah Mail - RE: [EXTERNAL] generator question for batch relocation to Lehi https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r6925194478135606974%7Cmsg-f:1801755931078645183…2/2