Loading...
HomeMy WebLinkAboutDAQ-2024-0086191 DAQC-624-24 Site ID 10337 (B4) MEMORANDUM TO: STACK TEST FILE – UTAH METAL WORKS INCORPORATED – Utah Metal Works THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Paul Bushman, Environmental Scientist DATE: June 24, 2024 SUBJECT: Sources: Unit 1: One (1) Wire Chopper Baghouse and Cyclone, Unit 2: Gravity Separator Baghouse and Cyclone, and One (1) Chopping Line Baghouse Contact: Brenda Terry: 801-364-5679 Location: Remote location in Uintah County, Utah Test Contractor: Alliance Technical Group Permit/AO#: DAQE-AN103370009-24 dated March 27, 2024 Action Code: TR Subject: Review of stack test report received June 6, 2024 On June 6, 2024, Utah Division of Air Quality (DAQ) received a test report for the Wire Chopper Baghouse, the Gravity Separator Baghouse, and the Chopping Line Baghouse at Utah Metal Works, Salt Lake County, Utah. Testing was performed May 7-10, 2024, to demonstrate compliance with the emission limits found in condition II.B.3.a of DAQE-AN103370009-24. The calculated test results are: Source Test Date Test Method Pollutant Tester Results DAQ Results Limits Unit #1: Wire Chopper Baghouse May 10, 2024 201A PM10 0.0011gr/dscf 0.0011 gr/dscf 0.020 gr/dscf 0.057 lb/hr 0.060 lb/hr 1.10 lb/hr Unit #2: Gravity Separator Baghouse May 9, 2024 201A PM10 0.0010 gr/dscf 0.00098 gr/dscf 0.020 gr/dscf 0.054 lb/hr 0.053 lb/hr 1.10 lb/hr Chopping Line Baghouse May 7-8, 2024 201A PM10 0.0010 gr/dscf 0.00097 gr/dscf 0.00133 gr/dscf 0.19 lb/hr 0.18 lb/hr 0.24 lb/hr DEVIATIONS: None. CONCLUSION: The stack test report appears to be acceptable. 2 RECOMMENDATION: The emissions from the above units appear to be in compliance with the PM10 limits in the Approval Order. However, the Chopping Line Baghouse also contains limits for PM2.5 which were not tested for during this stack test, and the test results for PM10 exceed the limits set for PM2.5. The source was contacted and reminded that the Approval Order requires the Wire Chopper Baghouse meet the limits in Condition II.B.3.a for PM2.5 and that they will need to a schedule test to determine compliance. ATTACHMENTS: DAQ stack test review excel spreadsheets, Utah Metal Works, Inc. stack test report, email to Utah Metal Works regarding PM2.5 limit. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84