Loading...
HomeMy WebLinkAboutDAQ-2024-0086171 DAQC-620-24 Site ID: 11689 (B4) MEMORANDUM TO: STACK TEST FILE – SCOUT ENERGY MANAGEMENT, LLC. – Monument Butte Compressor Station THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Paul Bushman, Environmental Scientist DATE: June 24, 2024 SUBJECT: Source: Three (3) Caterpillar G3516 TALE engines; Units 1 SN: 4EK0547, Unit 3 SN: 4EK04342, Unit 4 SN: 4EK01270 Location: Duchesne County, Utah Contact: Chris Breitling: 469-485-3418 Tester: Great Plains Analytical Services, Inc. Site ID #: 11689 Permit/AO #: Approval Order DAQE-AN116890012-15 dated October 21, 2015 Subject: Review of Pretest Protocol dated July 13, 2023 On June 21, 2024, Utah Division of Air Quality (DAQ) received a protocol for the testing of three Caterpillar G3516 TALE engines at Monument Butte Compressor Station in Duchesne County, Utah. Testing will be performed during the week of July 29, 2024, to determine compliance with the emission limits found in condition II.B.5.b of DAQE-AN116890012-15. PROTOCOL CONDITIONS: 1. RM 1 used to determine sample velocity traverses: OK 2. RM 2/2C used to determine stack gas velocity and volumetric flow rate: OK 3. RM 3A used to determine the dry molecular weight of the gas stream: OK 4. ASTM D6348-03 used to determine H2O, NOx, CO, and VOC emissions: OK DEVIATIONS: No deviations stated in the protocol. CONCLUSION: The protocol appears to be acceptable. RECOMMENDATION: Send protocol review and test date confirmation notice. ATTACHMENTS: Scout Energy Management, LLC. test notification letter and pretest protocol. 2 3 4 5 6 7 8 9 10 11 12