HomeMy WebLinkAboutDAQ-2024-0085770 HoLcrM UTAH DEPARTMENT OF ENVIBONMENTAL OUAUTY DEC - 9 20??_ DIVISION OF AIR QUALITY 2. ). To: Executive Secretaryo Utah Air Quality Board From: Holcim -US, Utelite Plant RE: Deviation Report For Permit No. 4300001003 Date: 1112912022 In accordance with Operating Permit Provision I.S.2.b, Utah Administrative Code (UAC) R3 07-4 I 5-6a(3)(c)(ii) the following report is submitted: 1. List the date the deviation occurrred: 1112512022 Permit conditions for which deviation occurred: II.B.3.b Describe the deviation that occurred: At 9:58am emissions greater than 10 percent opacity were emitted from the Number 3 stack. This condition existed for approximately 6 minutes. Describe the probable cause of the deviation: A sudden loss of pressure in the compressed air system caused a bypass of the baghouse. Describe any corrective actions or preventive measures taken: The kiln was shut down until air pressure could be restored. The cause was determined to be moisture freezing in an air line. Because of the frozen line, air pressure had to be routed to the bag house from a different air line. Once air pressure was restored the kiln was restarted. In accordance with Operating Permit provision I.K and UAC R307-415-5d, and based on information and belief formed after reasonable inquiry, I certify that the statements and information in this document are trueraccurate, and complete. ,I //- z.r' Tazz- of a Responsible Official Date 4. 5. ( Jeffery Barrick, General Manager REVIEWEDInitials:Date: June 12, 2024Compliance Status: OKFile #: 10676 (B2)Comment: Should have been reviewed at time of the July 21, 2023 . inspection.