Dear Ms. Cramm:
Re: Ames Construction – Temporary Relocation/Operation, Notice of Intent – Uintah County
Your Notice of Intent dated May 31, 2024, to relocate portable aggregate equipment to the
temporary project located from US 191, between mile posts 364.74 and 367.3 on the east side of
the road, near Vernal, UT, was received by the Utah Division of Air Quality (DAQ) and has been
reviewed.
The following equipment has been approved for operation for this temporary project:
KPI jaw crusher
KPI 4250 impactor CS plant
KPI 4250 impactor HSI crusher
JCI 3-deck screen
Cat C27 725 kW generator
Associated stackers, conveyors, loaders, and dozers
Approval is granted to relocate and operate this equipment at the new location for a period not to
exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the
operation of equipment at this temporary site may be for up to 180 working days in any calendar
year not to exceed 365 consecutive days, starting from the initial relocation date. The operational
days per site cannot be extended beyond the stipulated 365 consecutive day period. Approval is
subject to the conditions of the dust control plan submitted for this location and the current Ames
portable Approval Order (AO) DAQE-AN119410013-22, dated September 26, 2022. Hours of
operation shall be held to 15 hours each day. The maximum production rate shall be held to the
requested 600 tons per hour.
2 + " Ú Û Û Ù Û Ý
DAQC-547-24
Page 2
Emissions for this project have been estimated at the following:
Pollutant gram/sec lbs/hr lbs/24 hr tons/yr
PM10 2.31 18.35 183.45 14.31
SOx 0.92 7.32 73.24 5.71
NOx 6.11 48.49 484.88 37.82
CO 1.60 12.67 126.69 9.88
VOC 0.25 1.98 19.75 1.54
The owner/operator shall maintain records of the actual operation hours, days, and production rate
of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the Director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Federal New Source Performance Standards Supbart OOO requires that initial Method 9
observations be performed for all applicable portable crushers, screens, and attached conveyors.
Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after
April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep
maintenance records to ensure proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction
requirements for additional information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SPW:jl
Enclosure: Submitted Temporary Relocation Form
cc: TriCounty Health Department
4 * - - $ . — 0 ) @ @ v A ? A C @ @ w C B ˜
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Fri, May 31, 2024 at 4:02 PM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Ames Construction has requested a Temporary Relocation. Please see the information below. Any attachments
can be access by clicking on the links.
Recipient Data:
Time Finished: 2024-05-31 16:02:36 MDT
IP: 205.182.133.105
ResponseID: R_1SGPfwU1ILwtvHC
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/k4XjrVhAC0nuco%
2EIjK1m0hlDGhVsYpouG1tbr-0SIERPNfqPyWbNJhYaMELV29-5OzA6vI7uHvkY2uRpzpHP7uUkG98y2lovDcbM7gUf2VA-
2OLj6CEhEfSZzeDnjJpBjm8a51UDQAx81BqsKyIGG-OR6raEsPiDz84HV3280E%2EgdirclHyO8kjATT1ejtTWJB1NEBV
NyzOKpv0aMdHa8ULJcqgUG3LDgS2wco8-ma24RX6J2Ko14JthjZgMX%2ERXASmbSHU-
lndd6XehSApcnq39RnK9cMHQWHWGc2uFPTW%2ES2Fspgj9mJRMigqieaYDTRo3lfq15BsF1uTYPb4MAQ
Response Summary:
Please fill out the information below:
Contact Person: Olivia Cramm
Company Name: Ames Construction
Mailing Address: 3737 West 2100 South
City: Salt Lake City
Zip: 84120
Phone Number: 8019778012
Email: Oliviacramm@amesco.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
No
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
350B383010
Briefly give directions to the site and/or physical address:
take US 191, between mile posts 364.74 and 367.3 on the east side of the road
Proposed Relocation Information:
Closest City Vernal
County Uintah
UTM X Coordinates 629457.87
UTM Y Coordinates 4497890.69
Approximate distance to the nearest house/business .77 miles
UTM X Coordinates to nearest house/business 628777.35
UTM Y Coordinates to nearest house/business 4497812.26
Does this site currently have a permit with DAQ?
No
6/4/24, 11:15 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1800607330077646005%7Cmsg-f:1800607330077646005&…1/3
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
AN119410012-17
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Crusher
Make/Model KPI Jaw Crusher
Serial or ID# 411157
Manufactured Date 2007
Design Capacity 800 t/h
2
Equipment Type CS Plant
Make/Model KPI 4250 Impactor
Serial or ID# 419589
Manufactured Date 2020
Design Capacity 500 t/h
3
Equipment Type HSI Crusher
Make/Model KPI 4250 Impactor
Serial or ID# 419589
Manufactured Date 2020
Design Capacity 500 t/h
4
Equipment Type Screen
Make/Model JCI 3-Deck Screen
Serial or ID# S215294
Manufactured Date 2010
Design Capacity 500 t/h
5
Equipment Type conveyor
Make/Model Kimball Stackable
Serial or ID# 65974-1
Manufactured Date 2000
Design Capacity 700 t/h
6
Equipment Type Generator
Make/Model Cat C27
Serial or ID# T4Z00245
Manufactured Date 2014
Design Capacity 725 kw
7
Equipment Type Loader
Make/Model Cat
Serial or ID# MK610146
Manufactured Date 2018
Design Capacity 7 cyd
8
Equipment Type Dozer
Make/Model Cat D&T SU
Serial or ID# FMC01694
Manufactured Date 2018
Design Capacity NA
9
Equipment Type Stacker
Make/Model KPI Superstacker Conveyor
Serial or ID# 418196
Manufactured Date 2019
Design Capacity 700 t/h
10
Equipment Type conveyor
Make/Model LMW Stackable
Serial or ID# 3060-0496-1
Manufactured Date 1996
Design Capacity 700 t/h
6/4/24, 11:15 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1800607330077646005%7Cmsg-f:1800607330077646005&…2/3
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_4HMX4WoqHRbFRFT
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 15
Starting time of operation (am/pm) 7:00 am
Ending time of operation (am/pm) 7:00 pm
Maximum hourly production rate for project 600 t/h
Expected startup date 06/10/2024
Expected completion date 02/28/2025
What type of application is this for?
New Application
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2QEPsSMdkKzGLGP
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3fd7NqSxIN3bmmh
6/4/24, 11:15 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1800607330077646005%7Cmsg-f:1800607330077646005&…3/3