Loading...
HomeMy WebLinkAboutDAQ-2024-008545 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-547-24 Site ID 11941 (B1) Olivia Cramm Ames Construction 3737 West 2100 South Salt Lake City, UT 84120 Dear Ms. Cramm: Re: Ames Construction – Temporary Relocation/Operation, Notice of Intent – Uintah County Your Notice of Intent dated May 31, 2024, to relocate portable aggregate equipment to the temporary project located from US 191, between mile posts 364.74 and 367.3 on the east side of the road, near Vernal, UT, was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: KPI jaw crusher KPI 4250 impactor CS plant KPI 4250 impactor HSI crusher JCI 3-deck screen Cat C27 725 kW generator Associated stackers, conveyors, loaders, and dozers Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The operational days per site cannot be extended beyond the stipulated 365 consecutive day period. Approval is subject to the conditions of the dust control plan submitted for this location and the current Ames portable Approval Order (AO) DAQE-AN119410013-22, dated September 26, 2022. Hours of operation shall be held to 15 hours each day. The maximum production rate shall be held to the requested 600 tons per hour. 2 + " Ú Û Û Ù Û Ý DAQC-547-24 Page 2 Emissions for this project have been estimated at the following: Pollutant gram/sec lbs/hr lbs/24 hr tons/yr PM10 2.31 18.35 183.45 14.31 SOx 0.92 7.32 73.24 5.71 NOx 6.11 48.49 484.88 37.82 CO 1.60 12.67 126.69 9.88 VOC 0.25 1.98 19.75 1.54 The owner/operator shall maintain records of the actual operation hours, days, and production rate of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the Director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Federal New Source Performance Standards Supbart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens, and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SPW:jl Enclosure: Submitted Temporary Relocation Form cc: TriCounty Health Department 4 * - - $ . — 0 ) @ @ v A ? A C @ @ w C B ˜ Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Fri, May 31, 2024 at 4:02 PM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Ames Construction has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2024-05-31 16:02:36 MDT IP: 205.182.133.105 ResponseID: R_1SGPfwU1ILwtvHC Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/k4XjrVhAC0nuco% 2EIjK1m0hlDGhVsYpouG1tbr-0SIERPNfqPyWbNJhYaMELV29-5OzA6vI7uHvkY2uRpzpHP7uUkG98y2lovDcbM7gUf2VA- 2OLj6CEhEfSZzeDnjJpBjm8a51UDQAx81BqsKyIGG-OR6raEsPiDz84HV3280E%2EgdirclHyO8kjATT1ejtTWJB1NEBV NyzOKpv0aMdHa8ULJcqgUG3LDgS2wco8-ma24RX6J2Ko14JthjZgMX%2ERXASmbSHU- lndd6XehSApcnq39RnK9cMHQWHWGc2uFPTW%2ES2Fspgj9mJRMigqieaYDTRo3lfq15BsF1uTYPb4MAQ Response Summary: Please fill out the information below: Contact Person: Olivia Cramm Company Name: Ames Construction Mailing Address: 3737 West 2100 South City: Salt Lake City Zip: 84120 Phone Number: 8019778012 Email: Oliviacramm@amesco.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... No All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... 350B383010 Briefly give directions to the site and/or physical address: take US 191, between mile posts 364.74 and 367.3 on the east side of the road Proposed Relocation Information: Closest City Vernal County Uintah UTM X Coordinates 629457.87 UTM Y Coordinates 4497890.69 Approximate distance to the nearest house/business .77 miles UTM X Coordinates to nearest house/business 628777.35 UTM Y Coordinates to nearest house/business 4497812.26 Does this site currently have a permit with DAQ? No 6/4/24, 11:15 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1800607330077646005%7Cmsg-f:1800607330077646005&…1/3 Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) AN119410012-17 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Crusher Make/Model KPI Jaw Crusher Serial or ID# 411157 Manufactured Date 2007 Design Capacity 800 t/h 2 Equipment Type CS Plant Make/Model KPI 4250 Impactor Serial or ID# 419589 Manufactured Date 2020 Design Capacity 500 t/h 3 Equipment Type HSI Crusher Make/Model KPI 4250 Impactor Serial or ID# 419589 Manufactured Date 2020 Design Capacity 500 t/h 4 Equipment Type Screen Make/Model JCI 3-Deck Screen Serial or ID# S215294 Manufactured Date 2010 Design Capacity 500 t/h 5 Equipment Type conveyor Make/Model Kimball Stackable Serial or ID# 65974-1 Manufactured Date 2000 Design Capacity 700 t/h 6 Equipment Type Generator Make/Model Cat C27 Serial or ID# T4Z00245 Manufactured Date 2014 Design Capacity 725 kw 7 Equipment Type Loader Make/Model Cat Serial or ID# MK610146 Manufactured Date 2018 Design Capacity 7 cyd 8 Equipment Type Dozer Make/Model Cat D&T SU Serial or ID# FMC01694 Manufactured Date 2018 Design Capacity NA 9 Equipment Type Stacker Make/Model KPI Superstacker Conveyor Serial or ID# 418196 Manufactured Date 2019 Design Capacity 700 t/h 10 Equipment Type conveyor Make/Model LMW Stackable Serial or ID# 3060-0496-1 Manufactured Date 1996 Design Capacity 700 t/h 6/4/24, 11:15 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1800607330077646005%7Cmsg-f:1800607330077646005&…2/3 Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_4HMX4WoqHRbFRFT Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 15 Starting time of operation (am/pm) 7:00 am Ending time of operation (am/pm) 7:00 pm Maximum hourly production rate for project 600 t/h Expected startup date 06/10/2024 Expected completion date 02/28/2025 What type of application is this for? New Application In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2QEPsSMdkKzGLGP Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3fd7NqSxIN3bmmh 6/4/24, 11:15 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1800607330077646005%7Cmsg-f:1800607330077646005&…3/3