HomeMy WebLinkAboutDAQ-2024-0085401 DAQC-CI160010001-24 Site ID 16001 (B1) MEMORANDUM TO: FILE – KINDER MORGAN ALTAMONT, LLC – Farm Compressor Station THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Paul Bushman, Environmental Scientist DATE: June 13, 2024 SUBJECT: FULL COMPLIANCE EVALUATION, Minor, Duchesne County INSPECTION DATE: June 10, 2024 SOURCE LOCATION: 40.21552, -110.12150 Kinder Morgan's field office is located approximately 2 miles west of Altamont on UT-87. 17790 West 3750 North, Altamont. SOURCE CONTACTS: Garrett Taylor, Ops Manager 435-823-0823, Garrett_Taylor@kindermorgan.com Erin Dunman, EHS - Air Permitting and Compliance 713-628-2073, Erin_Dunman@kindermorgan.com OPERATING STATUS: Operating. PROCESS DESCRIPTION: Kinder Morgan Altamont, LLC (Kinder Morgan) operates a natural gas compressor station located in Altamont, UT. The stations primary function is to compress and dehydrate field gas. Natural gas from the Altamont field enters the site through pipelines. Incoming field gas is then sent through a slug catcher where free liquids are separated. The free liquids are directed to a gunbarrel tank where the free liquids are separated into water and condensate. The separated condensate is directed to two (2) condensate tanks and is stored to be removed via truck load-out. The separated water remains in the gunbarrel tank and is removed through truck load-out. Overhead vapor from the gunbarrel and condensate tanks is sent to the combustor. Overhead gas from the slug catcher is directed to a natural gas manifold connected to eight (8) natural gas-fired compressor engines. Natural gas for the compressor engines will be provided by the Altamont Main Gas Plant. Any liquid removed throughout the compression stages is recycled back to the inlet slug catcher. Compressed gas is directed to a sulfur scrubbing process. After treatment, the gas is discharged to the triethylene glycol (TEG) unit equipped with a flash tank and still vent condenser for the 2 removal of entrained water. Gas from the dehydration unit flash tank and still vent condenser is routed to the process/emergency flare. APPLICABLE REGULATIONS: Approval Order (AO) DAQE-AN160010006-23, dated August 1, 2023 NSPS (Part 60) JJJJ : Standards of Performance for Stationary Spark Ignition Internal Combustion Engines, NSPS (Part 60) OOOOa : Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015, MACT (Part 63) -HH : National Emission Standards for Hazardous Air Pollutants From Oil and Natural Gas Production Facilities, MACT (Part 63) -ZZZZ: National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines SOURCE EVALUATION: Name of Permittee: Permitted Location: Kinder Morgan Altamont, LLC Farm Compressor Station 1001 Louisiana Street, Suite 1000 PO Box 587 Houston, TX 77002 Altamont, 84001 SIC Code: 1311: (Crude Petroleum & Natural Gas) Section I: GENERAL PROVISIONS I.1 All definitions, terms, abbreviations, and references used in this AO conform to those used in the UAC R307 and 40 CFR. Unless noted otherwise, references cited in these AO conditions refer to those rules. [R307-101] I.2 The limits set forth in this AO shall not be exceeded without prior approval. [R307-401] Status: In Compliance. No limits appear to have been exceeded. I.3 Modifications to the equipment or processes approved by this AO that could affect the emissions covered by this AO must be reviewed and approved. [R307-401-1] Status: In Compliance. No modifications to the equipment or processes approved by this AO were observed during the inspection. I.4 All records referenced in this AO or in other applicable rules, which are required to be kept by the owner/operator, shall be made available to the Director or Director's representative upon request, and the records shall include the five-year period prior to the date of the request. Unless 3 otherwise specified in this AO or in other applicable state and federal rules, records shall be kept for a minimum of five (5) years. [R307-401-8] Status: In Compliance. Records are kept as required and were made available upon request at both the local field office and after the inspection via email. I.5 At all times, including periods of startup, shutdown, and malfunction, owners and operators shall, to the extent practicable, maintain and operate any equipment approved under this AO, including associated air pollution control equipment, in a manner consistent with good air pollution control practice for minimizing emissions. Determination of whether acceptable operating and maintenance procedures are being used will be based on information available to the Director which may include, but is not limited to, monitoring results, opacity observations, review of operating and maintenance procedures, and inspection of the source. All maintenance performed on equipment authorized by this AO shall be recorded. [R307-401-4] Status: In Compliance. The source appears to operate and maintain the equipment approved under the AO in a manner consistent with good air pollution control practices for minimizing emissions. I.6 The owner/operator shall comply with UAC R307-107. General Requirements: Breakdowns. [R307-107] Status: In Compliance. No breakdowns have been reported since the last inspection. I.7 The owner/operator shall comply with UAC R307-150 Series. Emission Inventories. [R307-150] Status: In Compliance. The source started operating June 6, 2022. Emission inventories for the 2023 operating year are still under review at this time. I.8 The owner/operator shall submit documentation of the status of construction or modification to the Director within 18 months from the date of this AO. This AO may become invalid if construction is not commenced within 18 months from the date of this AO or if construction is discontinued for 18 months or more. To ensure proper credit when notifying the Director, send the documentation to the Director, attn.: NSR Section. [R307-401-18] Status: In Compliance. The source submitted a notice of construction on March 15, 2024, stating that six of the eight reciprocating engines, C-1 through C-6, have been installed and are operational. See DAQ-2024-008008 Section II: SPECIAL PROVISIONS II.A The approved installations shall consist of the following equipment: II.A.1 Farm Compressor Station II.A.2 Six Natural gas-fired IC engines C-1, C-2, C-3, C-4, C-5, and C-6 Natural gas-fired IC engines, 4SRB Rating: 1,900 hp (each) Controls: AFCR and NSCR 4 II.A.3 Two Natural gas-fired IC engines C-7 and C-8 Natural gas-fired IC engines, 4SRB Rating: 840 hp (each) Control: AFCR and NSCR II.A.4 REB-1 TEG Dehydrator Reboiler with natural gas heater Rating: 1.0 MMBtu/hr II.A.5 Dehy-1 TEG Dehydrator Rating: 50 MMscf/day Control: Condenser, Flare (FL-1001), and Enclosed Combustor (CMB-2) II.A.6 CMB-1 Enclosed Combustor Capacity: 121 scfh (pilot) Controls: TK-1, TK-2, TK-3, TK-4, Truck Loading II.A.7 CMB-2 (NEW) Alternate Operating Scenario (AOS) Enclosed Combustor Capacity: 50 MMscf/day Controls: TEG Dehydrator II.A.8 CMB-3 (NEW) Standby Enclosed Combustor Capacity: 65 scfh Controls: TK-1, TK-2, TK-3, TK-4, Truck Loading II.A.9 FL-1001 Process/Emergency Flare Capacity: 50 MMscf/day Controls: Compressor engine maintenance and repair activities, TEG dehydrator, and emergencies II.A.10 TK-1, TK-2, and TK-4(NEW) Condensate Storage Tanks Capacity: 16,800 gallons (400 bbls) each Control: Enclosed Combustor II.A.11 TK-3 Gunbarrel Storage Tank Capacity: 16,800 gallons (400 bbls) Control: Enclosed Combustor II.A.12 MT-Tank Methanol Storage Tank Capacity: 16,800 gallons (400 bbls) II.A.13 FAB 5 Closed Loop Ultra-fab H2S Removal System *Listed for informational purposes only II.A.14 NGL-Tank 1 and NGL-Tank 2 (NEW) Capacity: 60,000 gallons (each) Contents: Pressurized NGL *Pressurized closed loop, listed for informational purposes only II.A.15 Miscellaneous Tanks Tank capacities: no greater than 400 bbl (each) (one NEW) Material stored: TEG, lube oil, used lube oil, auxiliary water storage, ultra-fab H2S scavenger and used ultra-fab H2S scavenger II.A.16 FUG Fugitive Emissions Natural Gas Compressor Station applicable to 40 CFR 60 Subpart OOOOa II.A.17 TRK1 Condensate Truck Loading Control: Vapor Capture Line II.A.18 TRK2 Closed loop NGL Truck Loading *Listed for informational purposes only Status: In Compliance. The above equipment was observed on site with the exception of the two 840 hp engines in II.A.3. No unapproved equipment was observed during the inspection. II.B Requirements and Limitations II.B.1 Site-wide Requirement II.B.1.a The owner/operator shall not allow visible emissions to exceed the following: A. Each of the combustors and flare - No visible emissions B. All other stationary points or fugitive emission sources on site - 10% opacity. [R307-401-8] II.B.1.a.1 Opacity observations of emissions from stationary sources shall be conducted according to 40 CFR 60, Appendix A, Method 9. [R307-201-3] Status: In Compliance. No visible emissions were observed from any point during the inspection. II.B.1.b The owner/operator shall route all gases, vapors, and fumes from the depressurization of the compressors and other equipment during emergencies, upset conditions, or planned maintenance to the operating process/emergency flare. [R307-401-8] 6 II.B.1.b.1 To determine compliance, the owner/operator shall keep records of all diversions to the emergency flare. Records shall include the following: A. The date the process/emergency flare was used B. The amount of natural gas routed to the process/emergency flare when used C. The reason for the process/emergency flare usage. [R307-401-8] Status: In Compliance. All gases, vapors, and fumes from the depressurization of the compressors and other equipment during emergencies, upset conditions, or planned maintenance is routed to the emergency flare. Records are kept as required. See attachments. II.B.2 Engines Testing Requirement II.B.2.a Source: C-1, C-2, C-3, C-4, C-5, C-6 Pollutant lb/hr NOx 2.09 CO 2.11 VOC 1.26 Source: C-7 and C-8 Pollutant lb/hr NOx 1.3 CO 2.23 VOC 0.56 [40 CFR 60 Subpart JJJJ, R307-401-8] II.B.2.a.1 Stack testing to show compliance with the emission limitations stated in the above condition shall be performed as specified below: Testing Emissions Point Pollutant Frequency Compressor Engines CO # NOx # VOC # A. Testing Frequency Compliance test at least once every 8,760 hours of operation or once every three years, whichever comes first. The Director may require testing at any time. B. Notification The Director shall be notified at least 30 days prior to conducting any required emission testing. A source test protocol shall be submitted to DAQ when the testing notification is submitted to the Director. The source test protocol shall be approved by the Director prior to performing the test(s). The source test protocol shall outline the proposed test methodologies, stack to be tested, and procedures to be used. A pretest conference shall be held, if directed by the Director. C. Sample Location 7 The emission point shall be designed to conform to the requirements of 40 CFR 60, Appendix A, Method 1, or other EPA testing methods as acceptable to the Director. An Occupational Safety and Health Administration (OSHA) or Mine Safety and Health Administration (MSHA) approved access shall be provided to the test location. D. Volumetric Flow Rate 40 CFR 60, Appendix A, Method 2, Method 19 or other EPA testing methods acceptable to the Director. E. NOx 40 CFR 60, Appendix A, Method 7, 7A, 7B, 7C, 7D or 7E, or other EPA testing methods acceptable to the Director. F. CO 40 CFR 60, Appendix A, Method 10, or other EPA testing methods acceptable to the Director. G. VOC 40 CFR 60, Appendix A, Method 18, 25, 25A, 40 CFR 63 Appendix A Method 320 or other EPA-approved testing method, as acceptable to the Director. H. Calculations To determine mass emission rates (lb/hr, etc.) the pollutant concentration as determined by the appropriate methods above shall be multiplied by the volumetric flow rate and any necessary conversion factors determined by the Director, to give the results in the specified units of the emission limitation. I. The owner/operator shall submit a copy of the results of the test to the Director within 60 day after the test has been completed. J. New Source Operation For a new source/emission point, the combustion rate during all compliance testing shall be no less than 90% of the capacity listed in Section II.A. If the maximum AO allowable combustion rate has not been achieved at the time of the test, the following procedure shall be followed: 1) Testing shall be at no less than 90% of the combustion rate achieved to date. 2) If the test is passed, the new maximum allowable combustion rate shall be 110% of the tested achieved rate, but not more than the maximum allowable combustion rate. This new allowable maximum combustion rate shall remain in effect until successfully tested at a higher rate. 3) The owner/operator shall request a higher combustion rate when necessary. Testing at no less than 90% of the higher rate shall be conducted. A new maximum combustion rate (110% of the new rate) will then be allowed if the test is successful. This process may be repeated until the maximum AO combustion rate is achieved. K. For an existing source/emission point, the production rate during all compliance testing shall be no less than 90% of the maximum production achieved in the previous three (3) years. [40 CFR 60 Subpart JJJJ, R307-401-8] 8 Status: In Compliance. Compressor engines C1-C6 were stack tested April 2-3, 2024. C-1 Pollutant (lb/hr) NOx 0.644 CO 1.138 VOC 0.024 C-2 Pollutant (lb/hr) NOx 0.088 CO 0.902 VOC 0.013 C-3 Pollutant (lb/hr) NOx 0.459 CO 0.512 VOC 0.008 C-4 Pollutant (lb/hr) NOx 0.356 CO 0.443 VOC 0.021 C-5 Pollutant (lb/hr) NOx 0.560 CO 0.100 VOC 0.010 C-6 Pollutant (lb/hr) NOx 0.123 CO 0.425 VOC 0.004 See DAQC-576-24. II.B.2.b The exhaust stack for each engine shall vent vertically unrestricted with no obstruction beyond the opening of the stack. Stack height shall be no less than the following: A. 40 feet as measured from the base of the stack for each compressor engine B. 10 feet as measured from the base of the stack for each generator engine. [R307-401-8] Status: In Compliance. The stacks appeared to be no less than 40 feet. II.B.3 Truck Loading Operations Requirements 9 II.B.3.a The owner/operator shall load all tanker trucks on site by the use of submerged loading. [R307-401-8] Status: In Compliance. Tanker trucks are loaded on site by the use of submerged loading. II.B.3.b The owner/operator shall connect a vapor capture line to the enclosed combustor for use during on-site condensate truck loading operations at the Farm Compressor Station. The vapor capture/return line shall be used at all times during loading operations. [R307-401-8] Status: In Compliance. A vapor capture line has been installed. II.B.4 Storage Tanks Requirements II.B.4.a The owner/operator shall not produce more than 12,756,324 gallons (42 gallons = 1 barrel) of condensate per rolling 12-month period. [R307-401-8] II.B.4.a.1 To determine compliance, the owner/operator shall: A. Determine production with company and/or customer billing records. B. Record production on a daily basis. C. Use the production data to calculate a new 12-month total by the 20th day of each month using data from the previous 12 months. D. Keep the production records for all periods the plant is in operation. [R307-401-8] Status: In Compliance. The rolling 12-month total for the period ending May 2024, was 4,689,865 gallons of condensate. See attachments. II.B.4.b At all times after startup of production, the owner/operator shall route all gases, vapors, and fumes from the gunbarrel tank and condensate storage tanks to the enclosed combustor. [R307-401-8] Status: In Compliance. All gases, vapors, and fumes appeared to be routed to the enclosed combustor. II.B.4.c The owner/operator shall keep the storage tank thief hatches and other tank openings closed and sealed except during tank unloading or other maintenance activities. [R307-401-8] Status: In Compliance. Thief hatches appeared closed and sealed during the inspection. II.B.5 LDAR Requirement II.B.5.a The owner/operator shall comply with the LDAR requirements in 40 CFR 60 Subpart OOOOa. [40 CFR 60 Subpart OOOO, 40 CFR 60 Subpart OOOOa, R307-401-8] Status: In Compliance. Subpart OOOOa applies to the six reciprocating compressor engines, and to the collection of fugitive components located at the compressor station. Kinder Morgan performs quarterly LDAR inspections. See attachments. 10 II.B.6 Enclosed Combustor and Flare Requirements II.B.6.a The enclosed combustor and flare shall operate with a continuous pilot flame and be equipped with an auto-igniter. [R307-401-8] Status: In Compliance. The combustor and the flare operate with a continuous pilot flame and are equipped with auto-igniters. Section III: APPLICABLE FEDERAL REQUIREMENTS In addition to the requirements of this AO, all applicable provisions of the following federal programs have been found to apply to this installation. This AO in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including UAC R307. NSPS (Part 60) JJJJ : Standards of Performance for Stationary Spark Ignition Internal Combustion Engines Status: In Compliance. The engines are maintained and stack tested as required. The most recent stack test for engines C-1, C-2, C-3, C-4, C-5, and C-6 occurred on April 2-3, 2024. See DAQC-576-24. NSPS (Part 60) OOOOa : Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015 Status: In Compliance. Subpart OOOOa applies to the six reciprocating compressor engines, and to the collection of fugitive components located at the compressor station. Kinder Morgan performs LDAR inspections, and replaces the rod packing every 36 months. See attachments. MACT (Part 63) -HH : National Emission Standards for Hazardous Air Pollutants From Oil and Natural Gas Production Facilities Status: In Compliance. Subpart HH does not apply to the site since there is exemption for TEG dehydration units that emit less than 0.90 tons of benzene per year. The permitted TEG dehydrator installed at the site was calculated to have a total potential to emit of 0.18 tons of benzene per year. All emissions from the TEG dehydrator process are routed to a combustor for control. MACT (Part 63) -ZZZZ: National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines Status: In Compliance. Compliance with subpart JJJJ satisfies compliance with subpart ZZZZ. AREA SOURCE RULES EVALUATION: The following Area Source Rules were evaluated during this inspection: Oil and Gas Industry: General Provisions [R307-501] Status: In Compliance. Equipment appeared to be installed, operated, and maintained in a manner consistent with good air pollution control practices for reducing emissions. 11 Oil and Gas Industry: Tank Truck Loading [R307-504] Status: In Compliance. Tanker trucks are loaded with submerged loading. A vapor capture line is installed to collect vapors and route them to the combustor. Oil and Gas Industry: Flares. [R307-503] Status: In Compliance. The combustor and the flare operate with a continuous pilot flame and are equipped with auto-igniters. EMISSION INVENTORY: The emissions listed below are an estimate of the total potential emissions (PTE) from Kinder Morgan Altamont, LLC – Farm Compressor Station on the Approval Order (AO) DAQE-AN160010006-23, dated August 1, 2023. PTE are supplied for supplemental purposes only. Criteria Pollutant PTE tons/yr CO2 Equivalent 68750.00 Carbon Monoxide 90.68 Nitrogen Oxides 70.94 Particulate Matter - PM10 5.55 Particulate Matter - PM2.5 5.55 Sulfur Dioxide 0.28 Volatile Organic Compounds 56.97 Hazardous Air Pollutant PTE lbs/yr Acrolein (CAS #107028) 240 Benzene (Including Benzene From Gasoline) (CAS #71432) 540 Formaldehyde (CAS #50000) 12720 Generic HAPs (CAS #GHAPS) 580 Hexane (CAS #110543) 2060 Methanol (CAS #67561) 540 Toluene (CAS #108883) 120 Xylenes (Isomers And Mixture) (CAS #1330207) 20 PREVIOUS ENFORCEMENT ACTIONS: No enforcement actions within the past five years. COMPLIANCE STATUS & RECOMMENDATIONS: In regards to Approval Order (AO) DAQE-AN160010006-23, dated August 1, 2023: In Compliance. The facility appears to be well maintained and operated. Required records were current and made available both during the inspection and afterwards via email. HPV STATUS: Not Applicable. 12 RECOMMENDATION FOR NEXT INSPECTION: Inspect at the regular inspection frequency for this type of source. Contact Kinder Morgan prior to the inspection to ensure access to the facility. NSR RECOMMENDATIONS: ATTACHMENTS: Applicable Supporting Documentation Included. STATE OF UTAH, DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF AIR QUALITY Page _of_ EPA METHOD 9 -VISIBLE EMISSION OBSERVATION FORM Source Name: F~, M LcJMpf~5scJ r )f-_{,'o/\ Street Address: City/County: Ati"""""Q:'\+-ur Duc.l,W5/\~ I Phone: Site ID: I b OD \ Equipment/Process: Control Equipment: Emission Point: Sky Conditions: Clear [ ] Partly Cloudy [ ] Overcast [ ] Precipitation: No [ ] Yes [ ] Wind: Direction: ___ Speed: __ _ mph AmbientTemp: ___ °F RH: __ _ % Height Relative to Observer: ___ _ Distance From Observer: ---- Condensed Water Vapor Present: No [ ] Yes [ ] Attached [ ] Detached [ ] Length of Condensed Water Vapor Plume: ______ _ Background: _______________ _ Sketch process unit: indicate observer position relative to source; indicate potential emission points and/or actual emission points. 0 Draw nonh arrow • observer ~--___;;::,,,.._ Sun ♦ Wind ► E • • . m1ss1on Point with Plume ( ) Observer Position x ___ _, Observer's Signature: Li_ ~ ,I,. ; c/~ Distrib: white-file; canary-ins ec . . P tor, Pink-owner/operator OBSERVATION DATE: (, Ito /zoz.y Start time: ____ Stop time: ___ _ ~ c mm 0 15 30 45 1 2 3 4 5 6 7 8 9 10 1 1 12 1 have received a copy of these observations: SIGNATURE: ~~~-5.L'.'~-'----_______ _ Printed Name: &,,d/: ~(Cr Rolling con~ensate 2024 l e urrc n t Pro du c t \onl l\m \t Production February M a rch April M a y J une July August Septem b er Octobe r Novem b e r December G a llons January -r r 194 ,469 134 ,087 111 ,526 105 ,7 14 87 ,475 Bluebell Compressor Sta ,on . 1,748,082 1,675,453 1 ,561 ,615 1 ,437 ,115 1 ,389 ,667 1 ,292,756 1 ,234 ,679 1 ,1 52 ,977 1 ,053 ,258 949 ,545 806 ,762 633 ,271 4 ,250,0 00 Rolling Production 200 32,384 25 ,94 6 0 10 ,279 Bluebell Plant 26,952 50,361 68 ,007 74 ,607 94 ,175 91 ,738 9 7 ,338 98 ,438 79 ,432 68 ,909 67 ,309 68 ,809 13,000 ,00 0 Rolling Production 109 ,309 53 ,954 5 5 ,007 163,011 78 ,313 East Compressor Station 1,654,139 1 ,685,608 1,747,719 1 ,697 ,570 1,552 ,8 4 2 1 ,3 8 9 ,871 1 ,252 ,088 1 ,130,071 966 ,515 765 ,302 623 ,543 459 ,594 4 ,250,000 Rolling Production 290 ,485 161 ,073 127 ,167 2 61 ,779 Farm compressor Station 596,841 Rolling Production :,5,040,455 5 ,072,319 4 ,907,338 4 ,738 ,679 4 ,689 ,865 4,225,0 99 3 ,904,985 3 ,488 ,973 3 ,070 ,362 2 ,559 ,473 1 ,947 ,999 1 ,437,345 12,756,324 Rabbit Gulch compressor Station 103,880 11 4 ,861 103,64 9 136 ,244 146 ,256 Rolling Production '71,255,976 1,227,022 1 ,177,497 1,158 ,104 1,1 85 ,774 1,08 0 ,193 1 ,013 ,874 906 ,981 840 ,849 7 74 ,936 698 ,162 604,890 4,250,000 Ravo lla Compressor Station 227,229 185,972 197,976 123,954 175,477 Rolling Production ~.964,681 2 ,828,258 2 ,633,045 2 ,374,229 2 ,3 25,3 06 2 ,191,530 2 ,111 ,698 1,979 ,6 2 6 1 ,778 ,779 1 ,4 57 ,361 1 ,1 16,408 910,608 13,000,000 South Compressor Station 261 ,280 182,068 177,336 150 ,968 239 ,834 Rolling Production 2,472,557 2 ,450,920 2,422,402 2 ,335,868 2 ,36 6 ,525 2 ,207 ,35 6 2 ,046 ,997 1 ,898 ,595 1 ,739 ,204 1 ,540 ,873 1 ,291 ,985 1 ,01 1,486 7 ,000,000 West Compressor Station 53,375 18,7 12 37,244 81 ,0 73 6 6 ,123 Rolling Production 638,926 612,194 592,839 609 ,4 4 9 6 3 5 ,962 5 96 ,223 5 56,616 517 ,577 478 ,753 425 ,291 323,554 256,527 4,250,000 j  40 CFR Part 60 ‐ Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015 ‐ §60.5420a(b) Annual Report 40 CFR Part 60 ‐ Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015 ‐ §60.5420a(b) Annual Report For each reciprocating compressor affected facility, an owner or operator must include the information specified in §60.5420a(b)(4)(i) through (iii) in all annual reports. Note : Deviation information required by §60.5420a(b)(4)(ii) should be reported on the Deviations tab. Information required by §60.5420a(b)(4)(iii) should be reported on the Closed Vent Systems tab.  Site            Record No. selections appear once Facility Site Name(s) are added to Site Information worksheet. If you answer yes in Column D, cells that are not relevant will be shaded in black. Site Record No.  (Select from dropdown list) Reciprocating Compressor ID (§60.5420a(b)(1)(ii)) Are emissions from the rod packing being  routed to a process through a closed vent  system under negative pressure? (§60.5420a(b)(4)(i)) (Select from dropdown list) What are the cumulative number of hours or months of  operation since initial startup, since August 2, 2016, or  since the previous reciprocating compressor rod packing  replacement (whichever is later)? (§60.5420a(b)(4)(i)) Units of Time Measurement (§60.5420a(b)(4)(i)) (Select from dropdown list) RecordId RecipCompressorID RodEmissionsFlag OpCumTime OpCumUnit e.g.: ABC Company XYZ  Compressor Station e.g.: Comp‐12b e.g.: Yes e.g.: e.g.: e.g.: ABC Company 123  Compressor Station e.g.: Comp‐6a e.g.: No e.g.: 6 e.g.: months Kinder Morgan Altamont LLC Farm  Compressor Station C‐1 No 6.9 months Kinder Morgan Altamont LLC Farm  Compressor Station C‐2 No 6.9 months Kinder Morgan Altamont LLC Farm  Compressor Station C‐3 No 1.5 months Reciprocating Compressor Page 1 Submitted via EPA CEDRI March 19, 2024 Director US EPA Region 8 Office of Enforcement, Compliance and Environmental Justice 1595 Wynkoop Street, Mail Code 8ENF Denver, CO 80202-1129 Re: Kinder Morgan Altamont LLC Farm Compressor Station, Approval Order DAQE-AN160010003-23 NSPS OOOOa Annual Report As required by 40 CFR §60.5420a(b), Kinder Morgan Altamont LLC is providing the initial annual report for reciprocating compressors C-1, C-2, C-3, C-4, C-5, C-6, and the collection of fugitive components, located at the Farm Compressor Station. Reciprocating compressors C-1, C-2, C-3, C-4, C-5, C-6, and the collection of fugitive components at Farm Compressor Station are affected facilities with respect to NSPS OOOOa, Standards of Performance for Crude Oil and Natural Gas Facilities. This report is being submitted for the compliance period beginning on January 1, 2023 and ending on December 31, 2023. It is Kinder Morgan’s understanding that sources in the production and processing segments that commenced construction, reconstruction, or modification after September 18, 2015 are subject to the methane requirements in the 2016 NSPS and the VOC requirements in the 2020 Technical Rule, as amended on September 15, 2020. As such, reporting elements from both versions of NSPS OOOOa are being provided. The following documents are attached:  CEDRI Excel Template v3.00 dated 4/8/2021 – this template includes reporting elements for VOC as required by the 2020 Technical Amendment.  PDF of applicable pages from the CEDRI Excel Template v2.01 dated 7/22/2020 – these documents include reporting elements for methane as required by the 2016 NSPS. If you have any questions about this submittal, please contact me at (303) 914-7605 or by email at Erin_Dunman@KinderMorgan.com. Sincerely, Erin Dunman Environmental Engineer The asterisk (*) next to each field indicates that the corresponding field is required. PE Certification Facility Record No. * (Field value will  automatically  generate if a value  is not entered.) Company Name *  (§60.5420a(b)(1)(i)) Facility Site Name *  (§60.5420a(b)(1)(i)) US Well ID or US Well ID  Associated with the  Affected Facility, if  applicable. *  (§60.5420a(b)(1)(i)) Address of Affected  Facility *  (§60.5420a(b)(1)(i)) Address 2  City * County * State  Abbreviation *Zip Code * Responsible  Agency  Facility ID  (State  Facility  Identifier) Description of Site Location  (§60.5420a(b)(1)(i)) Latitude of the Site (decimal  degrees to 5 decimals using the  North American Datum of 1983)  (§60.5420a(b)(1)(i)) Longitude of the Site  (decimal degrees to 5  decimals using the North  American Datum of 1983)  (§60.5420a(b)(1)(i)) Beginning Date of  Reporting Period.*  (§60.5420a(b)(1)(iii)) Ending Date of  Reporting Period.*  (§60.5420a(b)(1)(iii))  Please provide the file name  that contains the certification  signed by a qualified  professional engineer for each  closed vent system routing to a  control device or process. * (§60.5420a(b)(12)) Please provide only one file per  record. Please enter  any additional  information. Enter associated file  name reference.  XML Tag: FacilityName SiteName WellID AddressLine1 AddressLine2 CityName CountyName StateName ZIPCode StateFacID SiteDescription SiteLatitude SiteLongitude  PeriodStartDate PeriodEndDate PeCertFile AddInfo AddFile e.g.: ABC Company e.g.: XYZ Compressor  Station e.g.: 12‐345‐67890‐12 e.g.: 123 Main Street e.g.: Suite 100 e.g.: Brooklyn e.g.: Kings Countye.g.: NY e.g.: 11221 e.g.: 7 miles NE of the  intersection of Hwy 123 and  Hwy 456 e.g.: 34.12345 e.g.: ‐101.12345 e.g.: 01/01/2016 e.g.: 06/30/2016 e.g.: Certification.pdf or  XYZCompressorStation.pdf e.g.: addlinfo.zip or  XYZCompressorStation. pdf 1 Kinder Morgan Altamon Farm Compressor Station Myton Duchesne UT 84052 3.6 miles NW of Myton, UT 40.21999 ‐110.13031 4/27/2021 1/1/2023 12/31/2023 REPORTING INFORMATION ADDITIONAL INFORMATIONSITE INFORMATION ALTERNATIVE ADDRESS INFORMATION (IF NO PHYSICAL ADDRESS AVAILABLE FOR SITE *) 40 CFR Part 60 ‐  For the collection of fugitive emissions components at each well site and the collection of fugitive emissions components at each compressor station within the company‐defined area, an owner or operator must include the records of each monitoring survey including the information specified in paragraphs (b)(7)(i) through (xii) of this section in all annual reports:  The asterisk (*) next to each field indicates that the corresponding field is required. OGI Facility Record No. *  (Select from  dropdown list ‐ may  need to scroll up) Identification of Each  Affected Facility *  (§60.5420a(b)(1)) Date of Survey *  (§60.5420a(b)(7)(i)) Survey Begin Time *  (§60.5420a(b)(7)(ii)) Survey End Time *  (§60.5420a(b)(7)(ii)) Name of Surveyor *  (§60.5420a(b)(7)(iii)) Ambient Temperature  During Survey *  (§60.5420a(b)(7)(iv)) Sky Conditions During  Survey *  (§60.5420a(b)(7)(iv)) Maximum Wind Speed During Survey *  (§60.5420a(b)(7)(iv)) Monitoring Instrument Used  * (§60.5420a(b)(7)(v)) Deviations From Monitoring  Plan (If none, state none.) *   (§60.5420a(b)(7)(vi))  Type of Component for which  Fugitive Emissions Detected *   (§60.5420a(b)(7)(vii))  Number of Each Component Type for which Fugitive Emissions  Detected *   (§60.5420a(b)(7)(vii))  Type of Component Not Repaired as  Required in §60.5397a(h) *  (§60.5420a(b)(7)(viii))  Number of Each Component  Type Not Repaired as  Required in § 60.5397a(h) *  (§60.5420a(b)(7)(viii))  Type of Difficult‐to‐ Monitor Components  Monitored *  (§60.5420a(b)(7)(ix))  Number of Each Difficult‐ to‐Monitor Component  Type Monitored *  (§60.5420a(b)(7)(ix))  Type of Unsafe‐to‐Monitor Component Monitored *  (§60.5420a(b)(7)(ix))  Number of Each Unsafe‐to‐ Monitor Component Type  Monitored *  (§60.5420a(b)(7)(ix))  Date of Successful Repair of Fugitive  Emissions Component *  (§60.5420a(b)(7)(x))  Type of Component  Placed on Delay of Repair  * (§60.5420a(b)(7)(xi))   Number of Each  Component Type Placed  on Delay of Repair *  (§60.5420a(b)(7)(xi))   Explanation for Delay of  Repair *  (§60.5420a(b)(7)(xi))   Type of Instrument Used to Resurvey  Repaired Components Not Repaired During  Original Survey *  (§60.5420a(b)(7)(xii))   Training and Experience of Surveyor * (§60.5420a(b)(7)(iii)) Was a monitoring survey  waived under §  60.5397a(g)(5)? * (§60.5420a(b)(7)) If a monitoring survey was waived, the  calendar months that make up the  quarterly monitoring period for which  the monitoring survey was waived. * (§60.5420a(b)(7)) e.g.: Well Site ABC e.g.: 8/13/17 e.g.: 10:00 am e.g.: 1:00 pm e.g.: John Smith e.g.: 90°F e.g.: Sunny, no clouds e.g.: 2 mph e.g.: Company ABC optical  gas imaging camera e.g.: None e.g.: Valve e.g.: 3 e.g.: Valve e.g.: 1 e.g.: Valve e.g.: 1 e.g.:Valve e.g.: 1 e.g.: 11/10/16 e.g.: Valve e.g.: 1 e.g.: Unsafe to repair  until next shutdown e.g.: Company ABC optical gas imaging  camera e.g.: Trained thermographer; completed 40‐hour course at XYZ Training Center. Has 10 years of experience with OGI surveys.e.g.: Yes e.g.: January; February; and March 1 Farm Compressor Stat 1/3/2023 12:15 PM 4:30 PM Darin Ward 44 Overcast 6 mph FLIR GFX320, SN 74900625 None compressor, connector, pump 13 All components repaired as required 0 none 0 none 0 1/6/23, 1/18/23, 1/20/23, 1/21/23, 1/23/23none 0 not applicable OGI; Method 21 soap bubble test Completed FLIR Certified Level I Infrared Thermography Course No N/A 1 Farm Compressor Stat 4/19/2023 9:10 AM 5:30 PM Bryan McDougle 33 Overcast 7 mph FLIR GFX320, SN 74900223 None connector 8 All components repaired as required 0 none 0 none 0 4/19/23, 5/3/23 none 0 not applicable OGI; Method 21 soap bubble test Completed FLIR Certified Level I Infrared Thermography Course No N/A 1 Farm Compressor Stat 7/18/2023 9:50 AM 2:00 PM Bryan McDougle 78 Overcast 8 mph FLIR GFX320, SN 74900223 None connector 1 All components repaired as required 0 none 0 none 0 8/1/2023 none 0 not applicable OGI; Method 21 soap bubble test Completed FLIR Certified Level I Infrared Thermography Course No N/A 1 Farm Compressor Stat 10/25/2023 7:30 AM 5:00 PM Darin Ward 34 Sunny/Clear 6 mph FLIR GFX320, SN 74900625 None connector, valve 19 All components repaired as required 0 none 0 none 0 11/1/23, 11/2/23,  11/3/23, 11/20/23 none 0 not applicable OGI; Method 21 soap bubble test Completed FLIR Certified Level I Infrared Thermography Course No N/A Compressor Station Affected Facility Only Site Occurrence Level.Event Date Year Leak/Flare Incident Description Product Unit Of Measure Amount Released Category Duration Ravolla 1/1/2023 2023 Flare Flared 4.9 Mcf due to pigging maintenance. Not reportable.Natural Gas Mcf 4.9 Maintenance 24 hours Rabbit Gulch 5/1/2023 2023 Flare Flared 407 MCF due to C-2 down for low compressor oil pressure for 5 hours.Natural Gas Mcf 407 Maintenance 24 hours Ravolla 5/1/2023 2023 Flare Flared 906.7 MCF due to C-3 and C-6 down due to high temperatures.Natural Gas Mcf 906.7 Maintenance 24 hours Farm 5/1/2023 2023 Flare Flared 1571.2 MCF due to high discharge pressure caused by Myton Offload station shut down. DOGM 8146.Natural Gas Mcf 1571.2 Maintenance 24 hours Rabbit Gulch 5/2/2023 2023 Flare Flared 467 MCF due to C-2 down for six hours due to low compressor oil.Natural Gas Mcf 467 Maintenance 24 hours Ravolla 5/2/2023 2023 Flare Flared 5.2 MCF due to C-1, C-2, and C-3 down intermittently for emissions testing.Natural Gas Mcf 5.2 Maintenance 24 hours Farm 5/2/2023 2023 Flare Flared 44.7 MCF due to C-6 down due to high engine load.Natural Gas Mcf 44.7 Maintenance 24 hours Rabbit Gulch 5/3/2023 2023 Flare Flared 2.4 Mcf due to pigging maintenance Natural Gas Mcf 2.4 Maintenance 24 hours Ravolla 5/3/2023 2023 Flare Flared 2.5 Mcf due to pigging maintenance.Natural Gas Mcf 2.5 Maintenance 24 hours Farm 5/3/2023 2023 Flare Flared 32.45 MCF due to purge flare gas.Natural Gas Mcf 32.45 Maintenance 24 hours Rabbit Gulch 5/4/2023 2023 Flare Flared 49.6 MCF due to pigging maintenance Natural Gas Mcf 49.6 Maintenance 24 hours Ravolla 5/4/2023 2023 Flare Flared 3.8 mcf due to pigging maintenance.Natural Gas Mcf 3.8 Maintenance 24 hours Farm 5/4/2023 2023 Flare Flared 51.8 MCF due to C-5 down due to low engine speed.Natural Gas Mcf 51.8 Maintenance 24 hours Rabbit Gulch 5/5/2023 2023 Flare Flared 55.2 MCF due to C-1 down for unscheduled repairs and high station pressure.Natural Gas Mcf 55.2 Maintenance 24 hours Ravolla 5/5/2023 2023 Flare Flared 292.7 MCF due to C-7 down due to high crankcase pressure/mechanical.Natural Gas Mcf 292.7 Maintenance 24 hours Farm 5/5/2023 2023 Flare Flared 193.27 MCF due to high discharge pressure due to pigging.Natural Gas Mcf 193.27 Maintenance 24 hours Rabbit Gulch 5/6/2023 2023 Flare Flared 72.4 MCF due to valve repair on C-2.Natural Gas Mcf 72.4 Maintenance 24 hours Ravolla 5/6/2023 2023 Flare Flared 2.0 Mcf due to pigging maintenance.Natural Gas Mcf 2 Maintenance 24 hours Farm 5/6/2023 2023 Flare Flared 1941.09 MCF due to C-6, C-2, and C-1 down due to high discharge pressure caused by pigging and C-6, C-5, C- 4, C-2, C-1 down due to power outage. DOGM 8148 Natural Gas Mcf 1941.09 Maintenance 24 hours Ravolla 5/7/2023 2023 Flare Flared 41.7 MCF due to C-5 down due to level switch fault.Natural Gas Mcf 41.7 Maintenance 24 hours Farm 5/7/2023 2023 Flare Flared 4.96 MCF due to C-6 down for 1 hour due to High 1st Stage Scrubber Level.Natural Gas Mcf 4.96 Maintenance 24 hours Rabbit Gulch 5/7/2023 2023 Flare Flared 38.4 MCF due to units down at Farm and East CS causing build up in pressure.Natural Gas Mcf 38.4 Maintenance 24 hours Ravolla 5/8/2023 2023 Flare Flared 663.7 MCF due to C-5 down due to level switch fault.Natural Gas Mcf 663.7 Maintenance 24 hours Farm 5/8/2023 2023 Flare Flared 42.59 MCF due to C-6 down for approximately 1 hour due to High 1st Stage Scrubber Level.Natural Gas Mcf 42.59 Maintenance 24 hours Ravolla 5/9/2023 2023 Flare Flared 68.7 Mcf due to C-7 being down for 2.5 hours during emissions testing.Natural Gas Mcf 68.7 Maintenance 24 hours Farm 5/9/2023 2023 Flare Flared 1,501.5 Mcf due to C-1, C-2, & C-3 being down for 2 hours due to Myton VRU Shutdown/High Discharge Pressure. DOGM 8150 Natural Gas Mcf 1501.5 Maintenance 24 hours Ravolla 5/10/2023 2023 Flare Flared 113 Mcf due to C-2, C-5, and C-8 down on low suction from pigging.Natural Gas Mcf 113 Maintenance 24 hours Farm 5/10/2023 2023 Flare Flared 39.9 Mcf due to C-6 cracked aux. coolant line.Natural Gas Mcf 39.9 Repair 24 hours Ravolla 5/11/2023 2023 Flare Flared 545 Mcf due to high field pressure.Natural Gas Mcf 545 Emergency 24 hours Farm 5/11/2023 2023 Flare Flared 35.7 Mcf due to C-4 down on two spark plugs.Natural Gas mcf 35.7 Maintenance 24 hours Ravolla 5/12/2023 2023 Flare Flared 9.5 Mcf due to nothing down Natural Gas Mcf 9.5 Maintenance 24 hours Farm 5/12/2023 2023 Flare Flared 2351.9 Mcf due to losing all units on high discharge pressure caused by inadequate valve sizing on myton inlet. DOGM 8151 Natural Gas Mcf 2351.9 Emergency 24 hours Rabbit Gulch 5/13/2023 2023 Flare Flared 508.9 Mcf due to C-2 went down on low compressor oil pressure Natural Gas Mcf 508.9 Maintenance 24 hours Ravolla 5/13/2023 2023 Flare Flared 2 Mcf - Nothing Down Natural Gas Mcf 2 Maintenance 24 hours Farm 5/13/2023 2023 Flare Flared 61.4 Mcf due to C-1, C-2, & C-6 down on low suction because of cook pig Natural Gas Mcf 61.4 Maintenance 24 hours Rabbit Gulch 5/14/2023 2023 Flare Flared 172.1 Mcf due to West C-2 down for 3 hours for unscheduled repairs Natural Gas Mcf 172.1 Repair 24 hours Ravolla 5/14/2023 2023 Flare Flared 323.8 Mcf due to C-4 going down on high engine oil level Natural Gas Mcf 323.8 Maintenance 24 hours Farm 5/14/2023 2023 Flare Flared 216.9 Mcf due to C-2 down to change 2 bad spark plugs, C-6 down on high discharge pressure cause by inadequate valve sizing on myton inlet Natural Gas Mcf 216.9 Maintenance 24 hours Rabbit Gulch 5/15/2023 2023 Flare Flared 275.4 mcf due to high station pressure Natural Gas Mcf 275.4 Maintenance 24 hours Rabbit Gulch 5/16/2023 2023 Flare Flared 225 Mcf due to unit down at Ravolla.Natural Gas Mcf 225 Maintenance 24 hours Ravolla 5/16/2023 2023 Flare Flared 172.8 mcf due to C-2 being down for continued mechanical work.Natural Gas Mcf 172.8 Maintenance 24 hours Farm 5/16/2023 2023 Flare Flared 39.8 mcf - Nothing down Natural Gas Mcf 39.8 Maintenance 24 hours Rabbit Gulch 5/17/2023 2023 Flare Flared 74.9 mcf due to West Station being down causing pressure to build Natural Gas Mcf 74.9 Maintenance 24 hours Ravolla 5/17/2023 2023 Flare Flared 1.8 mcf - Nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Farm 5/17/2023 2023 Flare Flared 84.4 mcf due to C-2 being down for mechanical Natural Gas Mcf 84.4 Maintenance 24 hours Rabbit Gulch 5/18/2023 2023 Flare Flared 6.7 Mcf due to pigging maintenance.Natural Gas Mcf 6.7 Maintenance 24 hours Ravolla 5/18/2023 2023 Flare Flared 8.1 mcf - nothing down Natural Gas Mcf 8.1 Maintenance 24 hours Farm 5/18/2023 2023 Flare Flared 762.9 mcf due to C-1 and C-3 outage for 45 minutes due to inadequate valve sizing on Myton Inlet Natural Gas Mcf 762.9 Maintenance 24 hours Ravolla 5/19/2023 2023 Flare Flared 2.5 mcf - nothing down Natural Gas Mcf 2.5 Maintenance 24 hours Farm 5/19/2023 2023 Flare Flared 34.4 mcf - nothing down Natural Gas Mcf 34.4 Maintenance 24 hours Rabbit Gulch 5/20/2023 2023 Flare Flared 571 Mcf due to C-3 down on oil temp issues.Natural Gas Mcf 571 Maintenance 24 hours Ravolla 5/20/2023 2023 Flare Flared 2 mcf - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 5/20/2023 2023 Flare Flared 22.3 mcf - nothing fown Natural Gas Mcf 22.3 Maintenance 24 hours Rabbit Gulch 5/21/2023 2023 Flare Flared 500 mcf due to C-3 engine issues Natural Gas Mcf 500 Repair 24 hours Ravolla 5/21/2023 2023 Flare Flared 240.7 mcf due to C-2, C-3, and C-5 being down approx. 45 min due to influx of liquids sweep / pressure adjustment to station during mitigation.Natural Gas Mcf 240.7 Maintenance 24 hours Farm 5/21/2023 2023 Flare Flared 18.29 mcf - nothing down. Natural Gas Mcf 18.29 Maintenance 24 hours Rabbit Gulch 5/22/2023 2023 Flare Flared 635 Mcf due to C-3 down on oil level and C-2 down for unscheduled repair.Natural Gas Mcf 635 Maintenance 24 hours Ravolla 5/22/2023 2023 Flare Flared 4.8 mcf due to C-1 being down for mechanical Natural Gas Mcf 4.8 Maintenance 24 hours Farm 5/22/2023 2023 Flare Flared 74.3 mcf due to C-1, C-2 and C-6 being down for approx. 45 min. due to influx of liquids sweep/pressure adjustment to station during mitigation Natural Gas Mcf 74.3 Maintenance 24 hours Rabbit Gulch 5/23/2023 2023 Flare Flared 1330 Mcf due to C-3 down for repair.Natural Gas Mcf 1330 Repair 24 hours Ravolla 5/23/2023 2023 Flare Flared 26.5 mcf due to C-4 being down for 8K-PM Natural Gas Mcf 26.5 Maintenance 24 hours Farm 5/23/2023 2023 Flare Flared 19.4 due to C-6 being down due to high temps/mechanical Natural Gas Mcf 19.4 Maintenance 24 hours Rabbit Gulch 5/24/2023 2023 Flare Flared 1,567 mcf due to C-3 being down for approx. 7.5 hours. DOGM 8161 Natural Gas Mcf 1567 Maintenance 24 hours Ravolla 5/24/2023 2023 Flare Flared 3.1 mcf due to pigging maintenance.Natural Gas Mcf 3.1 Maintenance 24 hours Farm 5/24/2023 2023 Flare Flared 10.6 Mcf due to flare purge gas.Natural Gas Mcf 10.6 Maintenance 24 hours Rabbit Gulch 5/25/2023 2023 Flare Flared 712 mcf due to C-3 being down on oil leveler issues Natural Gas Mcf 712 Maintenance 24 hours Ravolla 5/25/2023 2023 Flare Flared 15.3 mcf - nothing down Natural Gas Mcf 15.3 Maintenance 24 hours Farm 5/25/2023 2023 Flare Flared 12.3 mcf - nothing down Natural Gas Mcf 12.3 Maintenance 24 hours Rabbit Gulch 5/26/2023 2023 Flare Flared 62 Mcf due to shutting down units to check and adjust fluids.Natural Gas Mcf 62 Maintenance 24 hours Ravolla 5/26/2023 2023 Flare Flared 1.8 mcf - Nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Farm 5/26/2023 2023 Flare Flared 12.3 mcf - nothing down Natural Gas Mcf 12.3 Maintenance 24 hours Rabbit Gulch 5/27/2023 2023 Flare Flared 2.8 mcf due to sending and receiving pigs Natural Gas Mcf 2.8 Maintenance 24 hours Ravolla 5/28/2023 2023 Flare Flared 93.5 mcf due to C-2, C-5, and C-8 going down on low suction caused by an incoming pig.Natural Gas Mcf 93.5 Maintenance 24 hours Farm 5/28/2023 2023 Flare Flared 44.5 mcf due to C-3 going down on low engine speed.Natural Gas Mcf 44.5 Maintenance 24 hours Rabbit Gulch 5/29/2023 2023 Flare Flared 50.7 mcf due to C-2 being down for 0.5 hours Natural Gas Mcf 50.7 Maintenance 24 hours Rabbit Gulch 5/30/2023 2023 Flare Flared 11739 MCF due to C-2 being down for scheduled 8K PM (DOGM 8163) (5/30: 3075 MCF; 5/31: 6115 MCF; 6/1: 2549 MCF)Natural Gas Mcf 11739 Maintenance 24 hours Ravolla 5/30/2023 2023 Flare Flared 141.9 mcf due to C-1 being scheduled down for top end/mechanical Natural Gas Mcf 141.9 Maintenance 24 hours Farm 5/30/2023 2023 Flare Flared 793.2 mcf due to Station PSD due to slug catcher high level/discharge valve positioner failure Natural Gas Mcf 793.2 Maintenance 24 hours Ravolla 5/31/2023 2023 Flare Flared 3.6 mcf due to C-1 being down for scheduled top end/mechanical Natural Gas Mcf 3.6 Maintenance 24 hours Farm 5/31/2023 2023 Flare Flared 11.3 mcf - nothing down Natural Gas Mcf 11.3 Maintenance 24 hours Ravolla 6/1/2023 2023 Flare Flared 14.2 mcf - nothing down Natural Gas Mcf 14.2 Maintenance 24 hours Farm 6/1/2023 2023 Flare Flared 14.5 mcf - nothing down Natural Gas Mcf 14.5 Maintenance 24 hours Ravolla 6/2/2023 2023 Flare Flared 3.7 mcf - nothing down Natural Gas Mcf 3.7 Maintenance 24 hours Farm 6/2/2023 2023 Flare Flared 19.5 mcf - nothing down Natural Gas Mcf 19.5 Maintenance 24 hours Ravolla 6/3/2023 2023 Flare Flared 6.2 mcf -nothing down Natural Gas Mcf 6.2 Maintenance 24 hours Farm 6/3/2023 2023 Flare Flared 27.2 mcf - nothing down Natural Gas Mcf 27.2 Maintenance 24 hours Ravolla 6/4/2023 2023 Flare Flared 90773.4 MCF total due to scheduled plant shutdown (DOGM 8175) 6/4: 11829.3 MCF; 6/5: 16858 MCF; 6/6: 17005.7 MCF; 6/7: 17786.4 MCF; 6/8: 17780 MCF; 6/9: 9514 MCF Natural Gas Mcf 90773.4 Maintenance 24 hours Farm 6/4/2023 2023 Flare Flared 36.08 MCF - nothing down Natural Gas Mcf 36.08 Maintenance 24 hours Rabbit Gulch 6/4/2023 2023 Flare Flared 85182 MCF due to scheduled Altamont Plant shutdown. (DOGM 8178) 6/4: 13374 mcf; 6/5: 14375 mcf; 6/6: 15142 mcf; 6/7: 13763; 6/8: 15414 mcf; 6/9: 13114 mcf Natural Gas Mcf 85182 Maintenance 24 hours Farm 6/5/2023 2023 Flare Flared 23.3 MCF - nothing down Natural Gas Mcf 23.3 Maintenance 24 hours Farm 6/6/2023 2023 Flare Flared 33.2 MCF - nothing down Natural Gas Mcf 33.2 Maintenance 24 hours Farm 6/7/2023 2023 Flare Flared 15 MCF - nothing down Natural Gas Mcf 15 Maintenance 24 hours Farm 6/8/2023 2023 Flare Flared 11 MCF - nothing down Natural Gas Mcf 11 Maintenance 24 hours Farm 6/9/2023 2023 Flare Flared 63 MCF - nothing down Natural Gas Mcf 63 Maintenance 24 hours Rabbit Gulch 6/10/2023 2023 Flare Flared 3,891 MCF due to Unit C-2 being down after startup. Unit repaired and put back online. (DOGM 8185)Natural Gas Mcf 3891 Maintenance 24 hours Ravolla 6/10/2023 2023 Flare Flared 179.7 MCF due to C-1, C-3, and C-5 going down due to low suction.Natural Gas Mcf 179.7 Maintenance 24 hours Farm 6/10/2023 2023 Flare Flared 9999 MCF due to high line pressure at Dominion resulting in shutting Myton down. (DOGM 8189)Natural Gas Mcf 9999 Maintenance 24 hours Rabbit Gulch 6/11/2023 2023 Flare Flared 153 MCF - nothing down Natural Gas Mcf 153 Maintenance 24 hours Ravolla 6/11/2023 2023 Flare Flared 1064.8 MCF due to C-1 going down due to suction control valve issue Natural Gas Mcf 1064.8 Emergency 24 hours Farm 6/11/2023 2023 Flare Flared 7993.7 MCF due to Units C-3 and C-4 intermittently going down due to low engine speed. DOGM 8251 Natural Gas Mcf 7993.7 Emergency 24 hours Ravolla 6/12/2023 2023 Flare Flared 91.5 MCF- nothing down Natural Gas Mcf 91.5 Maintenance 24 hours Farm 6/12/2023 2023 Flare Flared 77.5 MCF due to C-3 and C-4 going down on low engine speed Natural Gas Mcf 77.5 Maintenance 24 hours Rabbit Gulch 6/12/2023 2023 Flare Flared 106 MCF - nothing down Natural Gas Mcf 106 Maintenance 24 hours Ravolla 6/13/2023 2023 Flare Flared 231.5 MCF due to all units intermittent down for fan cleaning Natural Gas Mcf 231.5 Maintenance 24 hours Farm 6/13/2023 2023 Flare Flared 12.2 MCF - nothing down Natural Gas Mcf 12.2 Maintenance 24 hours Rabbit Gulch 6/14/2023 2023 Flare Flared 104.5 MCF due to unit down at South Station causing high pressure Natural Gas Mcf 104.5 Maintenance 24 hours Ravolla 6/14/2023 2023 Flare Flared 69.2 mcf due to C-1 being down for mechanical work Natural Gas Mcf 69.2 Maintenance 24 hours Farm 6/14/2023 2023 Flare Flared 79.15 mcf due to C-5 being down for 1.5 hrs for mechanical work Natural Gas Mcf 79.15 Maintenance 24 hours Rabbit Gulch 6/14/2023 2023 Flare Flared 112 MCF due to a unit being down at South station causing high pressure Natural Gas Mcf 112 Maintenance 24 hours Rabbit Gulch 6/15/2023 2023 Flare Flared 646 mcf due to C-1 being down for service and each unit was shut down for cooler cleaning Natural Gas Mcf 646 Maintenance 24 hours Ravolla 6/15/2023 2023 Flare Flared 156.3 mcf due to C-1 down for pending mechanical work Natural Gas Mcf 156.3 Maintenance 24 hours Farm 6/15/2023 2023 Flare Flared 41.3 mcf - nothing down Natural Gas Mcf 41.3 Maintenance 24 hours Ravolla 6/16/2023 2023 Flare Flared 192 mcf due to C-1 down for mechanical work Natural Gas Mcf 192 Maintenance 24 hours Farm 6/16/2023 2023 Flare Flared 8.5 mcf - nothing down Natural Gas Mcf 8.5 Maintenance 24 hours Rabbit Gulch 6/16/2023 2023 Flare Flared 126 mcf due to a unit down at South Station causing high station pressure Natural Gas Mcf 126 Maintenance 24 hours Rabbit Gulch 6/17/2023 2023 Flare Flared 136 mcf due to a unit down at South Station causing high station pressure Natural Gas Mcf 136 Maintenance 24 hours Ravolla 6/17/2023 2023 Flare Flared 374.2 mcf due to increased field pressure for 7 hrs due to units being down at Farm station for mechanical work Natural Gas Mcf 347.2 Maintenance 24 hours Farm 6/17/2023 2023 Flare Flared 58.4 mcf due to units being down for mechanical work Natural Gas Mcf 58.4 Maintenance 24 hours Rabbit Gulch 6/18/2023 2023 Flare Flared 123 mcf due to South C-3 being down for engine swing and modifications Natural Gas Mcf 123 Maintenance 24 hours Ravolla 6/18/2023 2023 Flare Flared 136.7 mcf due to C-1 being down for mechanical work Natural Gas Mcf 136.7 Maintenance 24 hours Farm 6/18/2023 2023 Flare Flared 17.5 mcf - nothing down Natural Gas Mcf 17.5 Maintenance 24 hours Rabbit Gulch 6/19/2023 2023 Flare Flared 123 mcf due to South C-3 being down for engine swing and modifications Natural Gas Mcf 123 Maintenance 24 hours Ravolla 6/19/2023 2023 Flare Flared 608.9 mcf due to C-1 being down for mechanical work Natural Gas Mcf 608.9 Maintenance 24 hours Farm 6/19/2023 2023 Flare Flared 17.04 mcf - nothing down Natural Gas Mcf 17.04 Maintenance 24 hours Rabbit Gulch 6/20/2023 2023 Flare Flared 301 mcf due to C-3 being down for a scheduled PM and South had a unit down Natural Gas Mcf 301 Maintenance 24 hours Ravolla 6/20/2023 2023 Flare Flared 6.4 mcf due to C-1 and C-6 being down for mechanical/ high coolant temps.Natural Gas Mcf 6.4 Maintenance 24 hours Farm 6/20/2023 2023 Flare Flared 14.5 mcf - nothing down Natural Gas Mcf 14.5 Maintenance 24 hours Rabbit Gulch 6/21/2023 2023 Flare Flared 60 mcf for pipeline pigging maintenance Natural Gas Mcf 60 Maintenance 24 hours Ravolla 6/21/2023 2023 Flare Flared 261.4 due to pipeline pigging mainteanance.Natural Gas Mcf 261.4 Maintenance 24 hours Farm 6/21/2023 2023 Flare Flared 21 mcf- nothng down.Natural Gas Mcf 21 Maintenance 24 hours Farm 6/22/2023 2023 Flare Flared 14.5 mcf - nothing down Natural Gas Mcf 14.5 Maintenance 24 hours Ravolla 6/22/2023 2023 Flare Flared 5.6 mcf - nothing down Natural Gas Mcf 5.6 Maintenance 24 hours Rabbit Gulch 6/22/2023 2023 Flare Flared 2 mcf - nothing down Natural Gas Mcf 2 Maintenance 24 hours Ravolla 6/23/2023 2023 Flare Flared 2 mcf - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 6/23/2023 2023 Flare Flared 55.94 mcf due to C-2 being down on low aux water level Natural Gas Mcf 55.94 Maintenance 24 hours Rabbit Gulch 6/24/2023 2023 Flare Flared 75 mcf due to C-1 being down due to control module fault in the unit Natural Gas Mcf 75 Maintenance 24 hours Ravolla 6/24/2023 2023 Flare Flared 1.9 mcf - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Farm 6/24/2023 2023 Flare Flared 11.07 mcf - nothing down Natural Gas Mcf 11.07 Maintenance 24 hours Ravolla 6/25/2023 2023 Flare Flared 3.4 mcf - nothing down Natural Gas Mcf 3.4 Maintenance 24 hours Farm 6/25/2023 2023 Flare Flared 8.7 mcf - nothing down Natural Gas Mcf 8.7 Maintenance 24 hours Rabbit Gulch 6/26/2023 2023 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Ravolla 6/26/2023 2023 Flare Flared 17 mcf - nothing down Natural Gas Mcf 17 Maintenance 24 hours Farm 6/26/2023 2023 Flare Flared 7.1 mcf - nothing down Natural Gas Mcf 7.1 Maintenance 24 hours Ravolla 6/27/2023 2023 Flare Flared 11.8 mcf - nothing down Natural Gas Mcf 11.8 Maintenance 24 hours Farm 6/27/2023 2023 Flare Flared 2.1 mcf - nothing down Natural Gas Mcf 2.1 Maintenance 24 hours Ravolla 6/28/2023 2023 Flare Flared 47.1 mcf due to C-8 and C-5 down for 30 min due to pipeline pigging maintenance.Natural Gas Mcf 47.1 Maintenance 24 hours Farm 6/28/2023 2023 Flare Flared 5 mcf - nothing down Natural Gas Mcf 5 Maintenance 24 hours Ravolla 6/29/2023 2023 Flare Flared 2.1 mcf - nothing down Natural Gas Mcf 2.1 Maintenance 24 hours Farm 6/29/2023 2023 Flare Flared 8.9 mcf - nothing down Natural Gas Mcf 8.9 Maintenance 24 hours Ravolla 6/30/2023 2023 Flare Flared 102.6 mcf due to Moon Lake Electric power outage in Bridgeland/Myton area - shut units down at Farm Station building station pressure Natural Gas Mcf 102.6 Maintenance 24 hours Farm 6/30/2023 2023 Flare Flared 1706.9 mcf due to Moon Lake Electric power outage in Bridgeland/Myton area - shut units down at Farm Station for 2 hours. (DOGM 8214)Natural Gas Mcf 1706.9 Emergency 24 hours Rabbit Gulch 6/30/2023 2023 Flare Flared 240 mcf due to C-2 down on low compressor oil pressure Natural Gas Mcf 240 Maintenance 24 hours Rabbit Gulch 7/1/2023 2023 Flare Flared 7.9 mcf due to high station pressure Natural Gas Mcf 7.9 Maintenance 24 hours Ravolla 7/1/2023 2023 Flare Flared 535 mcf due to engines going down intermittently Natural Gas Mcf 535 Maintenance 24 hours Farm 7/1/2023 2023 Flare Flared 30.3 mcf - nothing down Natural Gas Mcf 30.3 Maintenance 24 hours Ravolla 7/2/2023 2023 Flare Flared 419 mcf due to units being down due to mechanical work Natural Gas Mcf 419 Maintenance 24 hours Farm 7/2/2023 2023 Flare Flared 3.76 mcf - nothing down Natural Gas Mcf 3.76 Maintenance 24 hours Rabbit Gulch 7/3/2023 2023 Flare Flared 1.7 mcf due to sending and receiving line pigs Natural Gas Mcf 1.7 Maintenance 24 hours Ravolla 7/3/2023 2023 Flare Flared 398.5 mcf due to units being down for mechanical work Natural Gas Mcf 398.5 Maintenance 24 hours Farm 7/3/2023 2023 Flare Flared 12.6 mcf - nothing down Natural Gas Mcf 12.6 Maintenance 24 hours Ravolla 7/4/2023 2023 Flare Flared 2.2 mcf due to C-6 scheduled down Natural Gas Mcf 2.2 Maintenance 24 hours Farm 7/4/2023 2023 Flare Flared 16 mcf - nothing down Natural Gas Mcf 16 Maintenance 24 hours Ravolla 7/5/2023 2023 Flare Flared 18.1 mcf - nothing down Natural Gas Mcf 18.1 Maintenance 24 hours Farm 7/5/2023 2023 Flare Flared 6.2 mcf -nothing down Natural Gas Mcf 6.2 Maintenance 24 hours Rabbit Gulch 7/6/2023 2023 Flare Flared 1.6 mcf due to C-2 down on no flow Natural Gas Mcf 1.6 Maintenance 24 hours Ravolla 7/6/2023 2023 Flare Planned Outage: Flared 4790.8 Mcf due to planned shutdown at Farm CS to tie in new high pressure suction line. DOGM 8221.Natural Gas Mcf 4790.8 Maintenance 24 hours Farm 7/6/2023 2023 Flare Planned Outage: Flared 1840 Mcf due to station shutdown to tie-in new high pressure line. DOGM 8222.Natural Gas Mcf 1840 Maintenance 24 hours Rabbit Gulch 7/7/2023 2023 Flare Flared 473 mcf due to C-2 down on no flow and for low oil pressure Natural Gas Mcf 473 Maintenance 24 hours Ravolla 7/7/2023 2023 Flare Flared 776.7 mcf due to units shutdown on fire eye detection from contractors welding onsite Natural Gas Mcf 776.7 Maintenance 24 hours Farm 7/7/2023 2023 Flare Flared 1020 mcf due to units being shutdown from fire eye detection from contractors welding onsite.Natural Gas Mcf 1020 Maintenance 24 hours Rabbit Gulch 7/8/2023 2023 Flare Flared 1033 mcf due to C-2 being down Natural Gas Mcf 1033 Maintenance 24 hours Ravolla 7/8/2023 2023 Flare Flared 9.4 mcf - nothing down Natural Gas Mcf 9.4 Maintenance 24 hours Farm 7/8/2023 2023 Flare Flared 11.5 mcf - nothing down Natural Gas Mcf 11.5 Maintenance 24 hours Ravolla 7/9/2023 2023 Flare Flared 603.8 mcf due to C-5 going down on manifold air temp Natural Gas Mcf 603.8 Maintenance 24 hours Farm 7/9/2023 2023 Flare Flared 43 mcf due to C-1 going down on vibration switch high on cooler fan #2 Natural Gas Mcf 43 Maintenance 24 hours Rabbit Gulch 7/9/2023 2023 Flare Flared 294 mcf due to C-3 down for 3 hrs Natural Gas Mcf 294 Maintenance 24 hours Farm 7/10/2023 2023 Flare Flared 1228.8 MCF due to station pressured up due tonly being able to run a few units due to low fuel gas pressure.Natural Gas Mcf 1228.8 Maintenance 24 hours Ravolla 7/10/2023 2023 Flare Flared 3686.5 MCF on 7/10/23 and an additional 5711 MCF on 7/11/23 due to units going down intermittently due to high temperatures and Unit C-7 down for scheduled 8K service. DOGM 8228 Natural Gas Mcf 9397.5 Maintenance 24 hours Farm 7/11/2023 2023 Flare Flared 9999 mcf due to restricted residue gas to the station causing only 2-3 units being able to run. DOGM 8229 Natural Gas Mcf 9999 Maintenance 24 hours Ravolla 7/12/2023 2023 Flare Flared 2400 MCF due to planned Bluebell Plant turn around and Mountain West fuel pipeline work causing low residue volumes/pressure at the station. DOGM 8232 Natural Gas Mcf 2400 Maintenance 24 hours Farm 7/12/2023 2023 Flare Flared 6631.8 MCF due to Bluebell Plant turnaround and Mountain West fuel pipeline work causing low residue volumes/pressure. Unable to run 3 units at the station. Flared an additional 3463.2 Mcf on 7/13/23 and 4707.2 MCF on 7/14/23 due to low fuel gas pressure. DOGM 8233 Natural Gas Mcf 14802.2 Maintenance 24 hours Rabbit Gulch 7/12/2023 2023 Flare Flared 58 mcf due to C-2 engine swing at South Natural Gas Mcf 58 Maintenance 24 hours Ravolla 7/13/2023 2023 Flare Flared 145 Mcf due to multiple units down due to high temps.Natural Gas Mcf 145 Emergency 24 hours Ravolla 7/14/2023 2023 Flare Flared 1872.9 Mcf on 7/14/23 and flared an additional 1932 MCF on 7/15/23, 3079 MCF on 7/16/23, 4233 MCF on 7/17/23, and 1635 MCF on 7/18/23 due to units going down intermittently due to high temps. DOGM 8236 Natural Gas Mcf 12752 Emergency 24 hours Rabbit Gulch 7/15/2023 2023 Flare Flared 0.6 MCF due to receiving line pigs Natural Gas Mcf 0.6 Maintenance 24 hours Farm 7/15/2023 2023 Flare Flared 2 mcf - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 7/16/2023 2023 Flare Flared 2278.2 MCF due to C-5 going down due to mechanical work DOGM 8241 Natural Gas Mcf 2278.2 Maintenance 24 hours Rabbit Gulch 7/16/2023 2023 Flare Flared 3 MCF - nothing down Natural Gas Mcf 3 Maintenance 24 hours Farm 7/17/2023 2023 Flare Flared 6278 MCF due to units going down intermittently due to high temperatures. DOGM 8242 Natural Gas Mcf 6278 Emergency 24 hours Rabbit Gulch 7/17/2023 2023 Flare Flared 1220 MCF due to high temperatures.Natural Gas Mcf 1220 Maintenance 24 hours Farm 7/18/2023 2023 Flare Flared 3153 mcf due to C-3 going down 1 hour due to low engine speed and C-5 down for pending mechanical work. DOGM 8244 Natural Gas Mcf 3153 Maintenance 24 hours Rabbit Gulch 7/18/2023 2023 Flare Flared 274 MCF due to units intermittently going down due to high temperatures.Natural Gas Mcf 274 Emergency 24 hours Ravolla 7/19/2023 2023 Flare Flared 110 mcf due to C-4 going down on ESM and cylinder 4 misfire. Natural Gas Mcf 110 Emergency 24 hours Farm 7/19/2023 2023 Flare Flared 1202.9 mcf due to C-3 intermittent outage due to high coolant temperatures because belts were wearing off Natural Gas Mcf 1202.9 Maintenance 24 hours Rabbit Gulch 7/19/2023 2023 Flare Flared 967 mcf due to C-2 engine swing at South Natural Gas Mcf 967 Maintenance 24 hours Ravolla 7/21/2023 2023 Flare Flared 294.8 mcf due to high station pressure due to units down at Farm Natural Gas Mcf 294.8 Emergency 24 hours Farm 7/21/2023 2023 Flare Flared 1710.4 MCF due to C-3 and C-5 going down due to high engine speed and C-6 doing down due to low engine speed. DOGM 8246 Natural Gas Mcf 1710.4 Emergency 24 hours Rabbit Gulch 7/21/2023 2023 Flare Flared 2185 MCF due to high line pressure caused by 3 units going down at Farm Station. Producers have been notified, working to cut back gas. DOGM 8247 Natural Gas Mcf 2185 Emergency 24 hours Rabbit Gulch 7/22/2023 2023 Flare Flared 1523 MCF due to unit C-1 going down. DOGM 8248 Natural Gas Mcf 1523 Emergency 24 hours Ravolla 7/22/2023 2023 Flare Flared 31.2 MCF - nothing down Natural Gas Mcf 31.2 Maintenance 24 hours Farm 7/22/2023 2023 Flare Flared 6.3 MCF - nothing down Natural Gas Mcf 6.3 Maintenance 24 hours Rabbit Gulch 7/23/2023 2023 Flare Flared 268 mcf due to high station pressure Natural Gas Mcf 268 Emergency 24 hours Ravolla 7/23/2023 2023 Flare Flared 336.6 mcf due to C-2 going down due to high temperatures Natural Gas Mcf 336.6 Emergency 24 hours Farm 7/23/2023 2023 Flare Flared 385.1 mcf due to high station pressure Natural Gas Mcf 385.1 Emergency 24 hours Rabbit Gulch 7/24/2023 2023 Flare Flared 208 mcf due to units down at East and Ravolla Natural Gas Mcf 208 Emergency 24 hours Ravolla 7/24/2023 2023 Flare Flared 2991.6 mcf due to Unit C-2 going down due to high temperatures, Unit C-8 going down on spare, and station high pressure due to units down at Farm Station from power bump. DOGM 8255 Natural Gas Mcf 2991.6 Emergency 24 hours Farm 7/24/2023 2023 Flare Flared 4011.3 MCF due to all units going down due to a power bump. DOGM 8256 Natural Gas Mcf 4011.3 Emergency 24 hours Ravolla 7/25/2023 2023 Flare Flared 4023.6 MCF due to units going down intermittently due to high temperatures and Unit C-8 down for mechanical work. DOGM 8258 Natural Gas Mcf 4023.6 Emergency 24 hours Farm 7/25/2023 2023 Flare Flared 2399.6 due to high line pressure from Ravolla Station unit outages. DOGM 8259 Natural Gas Mcf 2399.6 Emergency 24 hours Rabbit Gulch 7/26/2023 2023 Flare Flared 108.3 MCF due to C-1 going down Natural Gas Mcf 108.3 Maintenance 24 hours Ravolla 7/26/2023 2023 Flare Flared 444 MCF due to a power bump and breaker trip at Myton Natural Gas Mcf 444 Emergency 24 hours Farm 7/26/2023 2023 Flare Flared 2555.2 MCF due to a power bump and breaker trip at Myton. DOGM 8262 Natural Gas Mcf 2555.2 Emergency 24 hours Ravolla 7/27/2023 2023 Flare Flared 1131.8 MCF due to C-8 down for mechanical and C- 2 down 3.5 hrs Natural Gas Mcf 1131.8 Maintenanace 24 hours Farm 7/27/2023 2023 Flare Flared 1477.1 MCF - nothing down Natural Gas Mcf 1477.1 Maintenanace 24 hours Ravolla 7/28/2023 2023 Flare Flared 2455 MCF due to units going down intermittently due to high temperatures and Unit C-8 down for mechanical work. DOGM 8264 Natural Gas Mcf 2455 Emergency 24 hours Farm 7/28/2023 2023 Flare Flared 4554 MCF due to C-3 and C-4 going down due to high temperatures. DOGM 8265 Natural Gas Mcf 4554 Emergency 24 hours Rabbit Gulch 7/28/2023 2023 Flare Flared 6.7 Mcf due to pigging maintenance.Natural Gas Mcf 6.7 Maintenance 24 hours Ravolla 7/29/2023 2023 Flare Flared 113 MCF due to C-2 down due to high engine oil temperatures Natural Gas Mcf 1113 Emergency 24 hours Farm 7/29/2023 2023 Flare Flared 4856 MCF due to high line pressure due to Unit C-8 at Ravolla CS down due to mechanical issues. DOGM 8266 Natural Gas Mcf 4856 Emergency 24 hours Ravolla 7/30/2023 2023 Flare Flared 832.5 MCF due to C-8 down for mechanical work and C-1 down due to high engine oil temps.Natural Gas Mcf 832.5 Maintenance 24 hours Farm 7/30/2023 2023 Flare Flared 5960 MCF due to Units C-1 and C-6 going down for 4 hours due to a mechanical issue with the spark plugs. DOGM 8268 Natural Gas Mcf 5960 Maintenance 24 hours Ravolla 7/31/2023 2023 Flare Flared 2336.8 MCF due to Unit C-8 down for mechanical work and Unit C-2 down for scheduled top-end service. DOGM 8269 Natural Gas Mcf 2336.8 Maintenance 24 hours Farm 7/31/2023 2023 Flare Flared 1322.8 MCF due to 2 units down at Ravolla Natural Gas Mcf 1322.8 Maintenance 24 hours Ravolla 8/1/2023 2023 Flare Flared 436.3 MCF due to scheduled C-2 top end service Natural Gas Mcf 436.3 Maintenance 24 hours Farm 8/1/2023 2023 Flare Flared 120.4 MCF due to a unit down at Ravolla Natural Gas Mcf 120.4 Maintenance 24 hours Rabbit Gulch 8/1/2023 2023 Flare Flared 17 MCF for scheduled pipeline maintenance Natural Gas Mcf 17 Maintenance 24 hours Rabbit Gulch 8/2/2023 2023 Flare Flared 30 MCF due to a power bump at Unit C-1 from a lightning storm Natural Gas Mcf 30 Emergency 24 hours Ravolla 8/2/2023 2023 Flare Flared 1066.5 due to high station pressure due to a power bump at Farm Station.Natural Gas Mcf 1066.5 Emergency 24 hours Farm 8/2/2023 2023 Flare Flared 2327.1 MCF due to all units going down due to a power bump at the station. DOGM 8271 Natural Gas Mcf 2327.1 Emergency 24 hours Rabbit Gulch 8/3/2023 2023 Flare Flared 91 MCF due to C-1 down for 8K PM Natural Gas Mcf 91 Maintenance 24 hours Ravolla 8/4/2023 2023 Flare Flared 469.8 MCF due to C-4 going down on misfire cylinder 6 Natural Gas Mcf 469.8 Emergency 24 hours Farm 8/4/2023 2023 Flare Flared 3082.4 MCF due to Units C-2 and C-6 going down due to high first stage suction pressure. DOGM 8272 Natural Gas Mcf 3082.4 Emergency 24 hours Rabbit Gulch 8/4/2023 2023 Flare Flared 304 MCF due to C-1 going down due to high temperatures.Natural Gas Mcf 304 Emergency 24 hours Rabbit Gulch 8/5/2023 2023 Flare Flared 2 MCF due to a unit down at Farm and Ravolla Natural Gas Mcf 2 Emergency 24 hours Ravolla 8/5/2023 2023 Flare Flared 565.3 MCF due to C-4 going down due to cylinder misfire Natural Gas Mcf 565.3 Emergency 24 hours Farm 8/5/2023 2023 Flare Flared 3860.8 MCF due to Unit C-6 going down due to low engine speed. DOGM 8273 Natural Gas Mcf 3860.8 Emergency 24 hours Ravolla 8/6/2023 2023 Flare Flared 69.1 MCF- nothing down Natural Gas Mcf 69.1 Maintenance 24 hours Farm 8/6/2023 2023 Flare Flared 5678.4 MCF due to a cylinder misfire on Unit C-5 causing the unit to go down. DOGM 8275 Natural Gas Mcf 5678.4 Emergency 24 hours Ravolla 8/7/2023 2023 Flare Flared 41.3 MCF due to C-8 going down due to 2nd stage scrubber high level Natural Gas Mcf 41.3 Emergency 24 hours Farm 8/7/2023 2023 Flare Flared 136.6 MCF due to purge gas flaring Natural Gas Mcf 136.6 Maintenance 24 hours Rabbit Gulch 8/7/2023 2023 Flare Flared 4 MCF due to Ravolla C8 going down Natural Gas Mcf 4 Maintenance 24 hours Ravolla 8/8/2023 2023 Flare Flared 69.6 MCF due to C-4 going down Natural Gas Mcf 69.6 Maintenance 24 hours Farm 8/8/2023 2023 Flare Flared 90.1 MCF - nothing down Natural Gas Mcf 90.1 Maintenance 24 hours Ravolla 8/9/2023 2023 Flare Flared 106.6 MCF due to C-1 down due to loose electrical connection.Natural Gas Mcf 106.6 Maintenance 24 hours Farm 8/9/2023 2023 Flare Flared 318.2 MCF due to C-5 and C-6 going down for mechanical Natural Gas Mcf 318.2 Maintenance 24 hours Rabbit Gulch 8/9/2023 2023 Flare Flared 198 MCF due to planned maintenance on C-2 at West Station causing high pressure. Natural Gas Mcf 198 Maintenance 24 hours Rabbit Gulch 8/10/2023 2023 Flare Flared 714 mcf due to units down at Ravolla due to high temps Natural Gas Mcf 714 Emergency 24 hours Ravolla 8/10/2023 2023 Flare Flared 851.3 mcf due to C-1, C-3, and C-6 going down due to heat related issues.Natural Gas Mcf 851.3 Emergency 24 hours Farm 8/10/2023 2023 Flare Flared 8.4 mcf- nothing down Natural Gas Mcf 8.4 Maintenance 24 hours Ravolla 8/11/2023 2023 Flare Flared 103.3 MCF due to C-4 down due to high exhaust temperature and C-6 down due to cylinder misfire Natural Gas Mcf 103.3 Emergency 24 hours Farm 8/11/2023 2023 Flare Flared 1678 MCF due to Units C-1, C-2, and C-3 going down intermittently due to scheduled mechanical work. DOGM 8283 Natural Gas Mcf 1678 Maintenance 24 hours Rabbit Gulch 8/11/2023 2023 Flare Flared 1169 MCF due to Ravolla Unit C-4 going down due to unscheduled repairs.Natural Gas Mcf 1169 Repair 24 hours Ravolla 8/12/2023 2023 Flare Flared 12.4 MCF due to C-4 going down for mechanical work.Natural Gas Mcf 12.4 Maintenance 24 hours Farm 8/12/2023 2023 Flare Flared 2.6 MCF - nothing down Natural Gas Mcf 2.6 Maintenance 24 hours Rabbit Gulch 8/12/2023 2023 Flare Flared 1001 MCF due to high station pressure due to a unit down at West Natural Gas Mcf 1001 Emergency 24 hours Rabbit Gulch 8/13/2023 2023 Flare Flared 639 MCF due to a unit down at West causing high station pressure.Natural Gas Mcf 639 Emergency 24 hours Ravolla 8/13/2023 2023 Flare Flared 145.4 MCF due to C-1 and C-3 down for pigging operation Natural Gas Mcf 145.4 Maintenance 24 hours Farm 8/13/2023 2023 Flare Flared 966.5 MCF due to C-2 and C-6 schdeuled down for 4 hours due to exceeding NOM allowance.Natural Gas Mcf 966.5 Maintenance 24 hours Ravolla 8/14/2023 2023 Flare Flared 208.6 MCF due to C-3 down for 8 hours for unscheduled maintenance work. Natural Gas Mcf 208.6 Maintenance 24 hours Farm 8/14/2023 2023 Flare Flared 2891 MCF due to a scheduled shutdown of Units C- 2 and C-3 due to exceeding NOM allowance and Unit C-3 being down 8 hours for unscheduled maintenance causing high station pressure at Farm. DOGM 8287 Natural Gas Mcf 2891 Maintenance 24 hours Rabbit Gulch 8/14/2023 2023 Flare Flared 706 MCF due to a unit down at West station causing high pressure.Natural Gas Mcf 706 Emergency 24 hours Rabbit Gulch 8/15/2023 2023 Flare Flared 1178 MCF due to Unit C-4 at Ravolla going down on low engine oil level causing high station pressure.Natural Gas Mcf 1178 Emergency 24 hours Ravolla 8/15/2023 2023 Flare Flared 982.3 MCF due to Unit C-4 going down on low engine oil level causing higher Harvest line pressure.Natural Gas Mcf 982.3 Emergency 24 hours Farm 8/15/2023 2023 Flare Flared 4504.3 MCF due to Unit C-4 at Ravolla going down on low engine oil level causing higher Harvest line pressure at Farm. DOGM 8291 Natural Gas Mcf 4504.3 Emergency 24 hours Ravolla 8/16/2023 2023 Flare Flared 171.1 MCF due to C-4 going down on high rod load.Natural Gas Mcf 171.1 Emergency 24 hours Farm 8/16/2023 2023 Flare Flared 9455.4 MCF due to Unit C-4 at Ravolla going down causing high pressure on Harvest line. DOGM 8293 Natural Gas Mcf 9455.4 Emergency 24 hours Rabbit Gulch 8/16/2023 2023 Flare Flared 3844 MCF due to high station pressure caused by Unit C-3 being out of service for 6 hours for a scheduled repair and Unit C-2 at West Station going down due to low compressor oil pressure. DOGM 8295 Natural Gas Mcf 3844 Maintenance 24 hours Farm 8/17/2023 2023 Flare Flared 6314.5 MCF due to Unit C-4 at Ravolla going down due to high rod load which caused high Harvest Line pressure to Farm. DOGM 8297 Natural Gas Mcf 6314.5 Emergency 24 hours Ravolla 8/17/2023 2023 Flare Flared 50.3 MCF due to Unit C-4 going down due to high rod load.Natural Gas Mcf 50.3 Emergency 24 hours Rabbit Gulch 8/17/2023 2023 Flare Flared 1775 MCF due to Unit C-4 at Ravolla going down due to high rod load causing high station pressure at Rabbit Gulch. DOGM 8298 Natural Gas Mcf 1775 Emergency 24 hours Ravolla 8/18/2023 2023 Flare Flared 5.5 MCF due to Unit C-4 going down due to low compressor oil Natural Gas Mcf 5.5 Emergency 24 hours Farm 8/18/2023 2023 Flare Flared 1894.1 MCF due to Unit C-2 going down due to low engine oil level and the oil beam sight glass breaking. DOGM 8299 Natural Gas Mcf 1894.1 Emergency 24 hours Rabbit Gulch 8/18/2023 2023 Flare Flared 678 MCF due to units down at Farm Station. Natural Gas Mcf 678 Emergency 24 hours Rabbit Gulch 8/19/2023 2023 Flare Flared 891 MCF due to Unit C-2 at Farm Station and Unit C- 2 at Rabbit Gulch going down.Natural Gas Mcf 891 Emergency 24 hours Ravolla 8/19/2023 2023 Flare Flared 3.1 MCF - nothing down Natural Gas Mcf 3.1 Maintenance 24 hours Farm 8/19/2023 2023 Flare Flared 11.3 mcf - nothing down Natural Gas Mcf 11.3 Maintenance 24 hours Ravolla 8/20/2023 2023 Flare Flared 13.4 MCF due to C-3 going down on low aux water from a tubing line breaking off the turbo Natural Gas Mcf 13.4 Emergency 24 hours Farm 8/20/2023 2023 Flare Flared 1992.4 MCF due to Unit C-3 going down 12 hours due to low compressor oil. DOGM 8300 Natural Gas Mcf 1992.4 Emergency 24 hours Rabbit Gulch 8/21/2023 2023 Flare Flared 234 MCF due to Unit C-1 at South going down due to Stage 3 discharge high temperature.Natural Gas Mcf 234 Emergency 24 hours Ravolla 8/21/2023 2023 Flare Flared 49 MCF due to C-3 going down due to a control module fault Natural Gas Mcf 49 Emergency 24 hours Farm 8/21/2023 2023 Flare Flared 4.9 MCF due to C-5 going down due to low engine oil pressure Natural Gas Mcf 4.9 Emergency 24 hours Rabbit Gulch 8/22/2023 2023 Flare Flared 428 MCF due to South C-3 down due to a strong storm Natural Gas Mcf 428 Emergency 24 hours Farm 8/22/2023 2023 Flare Flared 743.6 MCF due to C5 shutdown/engine oil low PSI Natural Gas Mcf 743.6 Emergency 24 hours Ravolla 8/22/2023 2023 Flare Flared 10.4 MCF due to C3 shutdown/engine control module.Natural Gas Mcf 10.4 Emergency 24 hours Farm 8/23/2023 2023 Flare Flared 12697.03 MCF due to the shut down of Units 1-6 at the station due to planned maintenance at the Myton slug catcher. Units were shutdown roughly 20 hours. DOGM 8303 Natural Gas Mcf 12697.03 Maintenance 24 hours Ravolla 8/23/2023 2023 Flare Flared 3570.1 MCF due to a shutdown of Unit C-3/engine control module for repair and planned maintenance at the Myton slug catcher. DOGM 8304 Natural Gas Mcf 3570.1 Maintenance 24 hours Rabbit Gulch 8/23/2023 2023 Flare Flared 456 MCF due to 2 units down at South for scheduled repairs.Natural Gas Mcf 456 Maintenance 24 hours Rabbit Gulch 8/24/2023 2023 Flare Flared 139 MCF due to C-2 at Farm down Natural Gas Mcf 139 Emergency 24 hours Farm 8/24/2023 2023 Flare Flared 758.95 MCF due to C-2 being down for 4 hours for repair Natural Gas Mcf 758.95 Repair 24 hours Ravolla 8/24/2023 2023 Flare Flared 5.8 MCF - nothing down Natural Gas Mcf 5.8 Maintenance 24 hours Rabbit Gulch 8/25/2023 2023 Flare Flared 496 MCF due to Ravolla C-2 and C-3 down for scheduled repairs.Natural Gas Mcf 496 Maintenance 24 hours Farm 8/25/2023 2023 Flare Flared 1.27 MCF due to C-2 down for 30 minutes.Natural Gas Mcf 1.27 Maintenance 24 hours Ravolla 8/25/2023 2023 Flare Flared 6.3 MCF due to C-8 shutdown due to high 2nd stage scrubber level Natural Gas Mcf 6.3 Maintenance 24 hours Rabbit Gulch 8/26/2023 2023 Flare Flared 210 MCF due to C-8 at Ravolla going down causing high station pressure Natural Gas Mcf 210 Emergency 24 hours Farm 8/26/2023 2023 Flare Flared 76.29 MCF due to C-5 shutdown for roughly 45 minutes due to Myton ESD Natural Gas Mcf 76.29 Emergency 24 hours Ravolla 8/26/2023 2023 Flare Flared 9.1 MCF due to C-8 shutdown due to high 2nd stage scrubber level Natural Gas Mcf 9.1 Emergency 24 hours Rabbit Gulch 8/27/2023 2023 Flare Flared 18 MCF due to West C-2 down on low compressor oil pressure Natural Gas Mcf 18 Maintenance 24 hours Farm 8/27/2023 2023 Flare Flared 457.31 MCF due to C-2 remote shutdown due to oil beam sight glass leaking oil and C-5 shutdown due to low engine speed.Natural Gas Mcf 457.31 Emergency 24 hours Ravolla 8/27/2023 2023 Flare Flared 5.6 MCF due to C-3 low aux water shutdown and C- 4 ESM shutdown.Natural Gas Mcf 5.6 Emergency 24 hours Farm 8/28/2023 2023 Flare Flared 366.86 MCF due to producers adjusting gas volume momentarily causing high line pressures.Natural Gas Mcf 366.86 Emergency 24 hours Ravolla 8/28/2023 2023 Flare Flared 3 MCF due to C-4 ESM shudown Natural Gas Mcf 3 Emergency 24 hours Rabbit Gulch 8/28/2023 2023 Flare Flared 440 MCF due to C-1 and C-4 at East Station going down due to a power bump.Natural Gas Mcf 440 Emergency 24 hours Rabbit Gulch 8/29/2023 2023 Flare Flared 173 MCF due to West Station C-2 down due to power bump, C-4 at Ravolla and C-6 at Farm down due to low compressor oil level Natural Gas Mcf 173 Emergency 24 hours Farm 8/29/2023 2023 Flare Flared 3429.3 MCF due to Unit C-6 shutting down for 1 hour due to low compressor oil level and Unit C-5 shutting down for 5 hours due to low engine speed. DOGM 8311 Natural Gas Mcf 3429.3 Emergency 24 hours Ravolla 8/29/2023 2023 Flare Flared 63.7 MCF due to C-4 and C-6 shutdown for low compressor oil Natural Gas Mcf 67.3 Emergency 24 hours Ravolla 8/30/2023 2023 Flare Flared 1197.8 MCF due to high inlet pressure due to C-3 going down due to control module fault and aux water high temp Natural Gas Mcf 1197.8 Emergency 24 hours Farm 8/30/2023 2023 Flare Flared 8048.5 MCF on 8/30/23 and an additional 7553 MCF on 8/31/23 due to high field pressure due to Unit C-1 going down due to fuel regulator and carburetor issues. DOGM 8314 Natural Gas Mcf 15601.5 Emergency 24 hours Rabbit Gulch 8/30/2023 2023 Flare Flared 251 MCF due to C-3 at West down for 8K service.Natural Gas Mcf 251 Maintenance 24 hours Ravolla 8/31/2023 2023 Flare Flared 277.7 mcf due to units going down on low suction due to planned pipeline maintenance Natural Gas Mcf 277.7 Maintenance 24 hours Rabbit Gulch 8/31/2023 2023 Flare Flared 3110 MCF on 8/31/23 and an additional 4817 MCF on 9/1/23, 5347 MCF on 9/2/23, 4799 MCF on 9/3/23, 5653 MCF on 9/4/23, and 10,423 MCF due to Unit C-1 going down due to repairs. DOGM 8316 Natural Gas Mcf 34149 Repair 24 hours Ravolla 9/1/2023 2023 Flare Flared 3.6 MCF - nothing down Natural Gas Mcf 3.6 Maintenance 24 hours Farm 9/1/2023 2023 Flare Flared 12.3 MCF due to C-6 going down on low compressor oil Natural Gas Mcf 12.3 Maintenance 24 hours Ravolla 9/2/2023 2023 Flare Flared 2.1 MCF - nothing down Natural Gas Mcf 2.1 Maintenance 24 hours Farm 9/2/2023 2023 Flare Flared 3.1 MCF - nothing down Natural Gas Mcf 3.1 Maintenance 24 hours Ravolla 9/3/2023 2023 Flare Flared 3.2 MCF - nothing down Natural Gas Mcf 3.2 Maintenance 24 hours Farm 9/3/2023 2023 Flare Flared 71.1 MCF due to C-6 going down on low compressor oil Natural Gas Mcf 71.1 Maintenance 24 hours Ravolla 9/4/2023 2023 Flare Flared 4.5 MCF due to C-3 LB Turbo oil leak Natural Gas Mcf 4.5 Emergency 24 hours Farm 9/4/2023 2023 Flare Flared 5104.6 MCF due to Unit C-6 going down due to low compressor oil and Unit C-5 going down due to high 2nd stage scrubber level. DOGM 8318 Natural Gas Mcf 5104.6 Emergency 24 hours Farm 9/5/2023 2023 Flare Flared 2.09 MCF due to C-6 shutdown due to low compressor oil Natural Gas Mcf 2.09 Maintenance 24 hours Ravolla 9/5/2023 2023 Flare Flared 6.5 MCF due to C-3 going down with leaking oil out of turbo Natural Gas Mcf 6.5 Maintenance 24 hours Rabbit Gulch 9/6/2023 2023 Flare Flared 4855 MCF on 9/6/23 and an additional 4560 MCF on 9/7/23, 5052 MCF on 9/8/23, 5787 MCF on 9/9/23, 4012 MCF on 9/10/23, 5117 MCF on 9/11/2023, 4584 MCF on 9/12/23, 4117 MCF on 9/13/23, 3637 MCF on 9/14/23, 4685 MCF on 9/15/23, 6907 MCF on 9/16/23, 7979 MCF on 9/17/23, 5910 MCF on 9/18/23, 5753 MCF on 9/19/23, 5969 MCF on 9/20/23, 6804 MCF on 9/21/23, 6574 MCF on 9/22/23, 5936 MCF on 9/23/23, 4722 on 9/24/23, 4701 MCF on 9/25/23, 5040 MCF on 9/26/23, 6791 MCF on 9/27/23, 6962 MCF on 9/28/23, 5861 MCF on 9/29/23, 5507 MCF on 9/30/23, 5430 MCF on 10/1/23, 5078 MCF on 10/2/23, and 2693 MCF on 10/3/23 due to Unit C-3 being down due to a bad crank on the compressor. DOGM 8323 Natural Gas Mcf 151023 Repair 24 hours Farm 9/6/2023 2023 Flare Flared 120.44 MCF due to C-6 shutdown on low compressor oil Natural Gas Mcf 120.44 Emergency 24 hours Ravolla 9/6/2023 2023 Flare Flared 2 MCF due to spike in suction pressure Natural Gas Mcf 2 Emergency 24 hours Ravolla 9/7/2023 2023 Flare Flared 2.2 MCF - nothing down Natural Gas Mcf 2.2 Maintenance 24 hours Farm 9/7/2023 2023 Flare Flared 2.7 MCF - nothing down Natural Gas Mcf 2.7 Maintenance 24 hours Ravolla 9/8/2023 2023 Flare Flared 731.5 MCF due to C-3 going down due to engine control module overheating Natural Gas Mcf 731.5 Emergency 24 hours Farm 9/8/2023 2023 Flare Flared 7532 MCF due to Unit C-3 going down due to high 2nd stage scrubber level and Unit C-6 going down due to low compressor oil level. DOGM 8327 Natural Gas Mcf 7532 Emergency 24 hours Ravolla 9/9/2023 2023 Flare Flared 584.6 MCF due to C-3 going down due to low aux water, C-7 going down due to 1st stage suction pressure high and C-4 going down on cylinder misfire.Natural Gas Mcf 584.6 Emergency 24 hours Farm 9/9/2023 2023 Flare Flared 6178.4 MCF due to Unit C-3 going down due to high 2nd stage scrubber level, Unit C-6 going down due to low compressor oil level, and Unit C-5 going down on low engine speed. DOGM 8328 Natural Gas Mcf 6178.4 Emergency 24 hours Ravolla 9/10/2023 2023 Flare Flared 2 mcf - nothing down Natural Gas Mcf 2 Emergency 24 hours Farm 9/10/2023 2023 Flare Flared 3 MCF due to C-6 down due to low compressor oil. Natural Gas Mcf 3 Emergency 24 hours Ravolla 9/11/2023 2023 Flare Flared 8 MCF due to C-7 down due to low jacket water Natural Gas Mcf 8 Maintenance 24 hours Farm 9/11/2023 2023 Flare Flared 1 MCF due to C-6 down due to low compressor oil for 1 hr.Natural Gas Mcf 1 Maintenance 24 hours Farm 9/12/2023 2023 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Ravolla 9/12/2023 2023 Flare Flared 14.4 MCF due to a unit down at Rabbit Gulch causing high station pressure.Natural Gas Mcf 14.4 Emergency 24 hours Farm 9/13/2023 2023 Flare Flared 1.3 MCF - nothing down Natural Gas Mcf 1.3 Maintenance 24 hours Ravolla 9/13/2023 2023 Flare Flared 12.8 MCF due to C-3 shutdown at Rabbit Gulch Natural Gas Mcf 12.8 Emergency 24 hours Farm 9/14/2023 2023 Flare Flared 1.74 MCF - nothing down Natural Gas Mcf 1.74 Maintenance 24 hours Ravolla 9/14/2023 2023 Flare Flared 4.8 MCF due to C-7 down for PM Natural Gas Mcf 4.8 Maintenance 24 hours Farm 9/15/2023 2023 Flare Flared 1.54 MCF - nothing down Natural Gas Mcf 1.54 Maintenance 24 hours Ravolla 9/15/2023 2023 Flare Flared 140.4 MCF due to C-4 and C-7 going down and high station pressure due to Rabbit Gulch unit being down Natural Gas Mcf 140.4 Maintenance 24 hours Farm 9/16/2023 2023 Flare Flared 1.35 MCF - nothing down Natural Gas Mcf 1.35 Maintenance 24 hours Ravolla 9/16/2023 2023 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 9/17/2023 2023 Flare Flared 49.08 MCF due to C-1 down on high suction pressure.Natural Gas Mcf 49.08 Emergency 24 hours Ravolla 9/17/2023 2023 Flare Flared 164.5 MCF due to C-3 shutdown at Rabbit Gulch Natural Gas Mcf 164.5 Emergency 24 hours Farm 9/18/2023 2023 Flare Flared 5.33 MCF - nothing down Natural Gas Mcf 5.33 Maintenance 24 hours Ravolla 9/18/2023 2023 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 9/19/2023 2023 Flare Flared 20.93 MCF due to C-2, C-3 and C-4 going down for PM Natural Gas Mcf 20.93 Maintenance 24 hours Ravolla 9/19/2023 2023 Flare Flared 96.8 MCF due to C-1 down for PM and C-3 out at Rabbit Gulch Natural Gas Mcf 96.8 Maintenance 24 hours Farm 9/20/2023 2023 Flare Flared 3.06 MCF - nothing down Natural Gas Mcf 3.06 Maintenance 24 hours Ravolla 9/20/2023 2023 Flare Flared 304.2 MCF due to C-7 and C-1 going down due to mechanical issues Natural Gas Mcf 304.2 Maintenance 24 hours Farm 9/21/2023 2023 Flare Flared 2776.94 MCF due to Units C-3, C-4, C-5, and C-6 being shutdown due to the installation of a new valve at Myton. DOGM 8339 Natural Gas Mcf 2776.94 Emergency 24 hours Ravolla 9/21/2023 2023 Flare Flared 2324.2 MCF due to Unit C-4 shutdown for routine maintenance. DOGM 8340 Natural Gas Mcf 2324.2 Maintenance 24 hours Farm 9/22/2023 2023 Flare Flared 156.67 MCF due to C-3, C-4, C-5, and C-6 maintenance.Natural Gas Mcf 156.67 Maintenance 24 hours Ravolla 9/22/2023 2023 Flare Flared 888.4 MCF due to C-3 shutdown at Rabbit Gulch.Natural Gas Mcf 888.4 Emergency 24 hours Farm 9/23/2023 2023 Flare Flared 3944.74 MCF due to Unit C-1 shutdown on high stage 3 scrubber level for 7.5 hours, Unit C-2 shutdown on high stage 3 scrubber level for 0.25 hours, and Unit C-3 shutdown on high stage 2 scrubber level for 8.5 hours. DOGM 8341 Natural Gas Mcf 3944.74 Emergency 24 hours Ravolla 9/23/2023 2023 Flare Flared 454.2 MCF due to C-7 shutdown on engine turbo exp tank level low for 1.5 hours.Natural Gas Mcf 454.2 Emergency 24 hours Farm 9/24/2023 2023 Flare Flared 4325.59 MCF due to Unit C-3 down due to high 2nd stage scrubber level and Unit C-2 down due to high 3rd stage scrubber level. DOGM 8342 Natural Gas Mcf 4325.59 Emergency 24 hours Ravolla 9/24/2023 2023 Flare Flared 1482.1 MCF due to C-3 down at Rabbit Gulch Natural Gas Mcf 1482.1 Emergency 24 hours Farm 9/25/2023 2023 Flare Flared 3178.49 MCF due to Units C-2 and C-3 going down due to 3rd stage scrubber dumps. DOGM 8344 Natural Gas Mcf 3178.49 Emergency 24 hours Ravolla 9/25/2023 2023 Flare Flared 410.6 MCF due to C-4 down on high crank case pressure for 15 hours Natural Gas Mcf 410.6 Emergency 24 hours Farm 9/26/2023 2023 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Ravolla 9/26/2023 2023 Flare Flared 7.3 MCF due to C-4 and C-3 shutdown for mechanical issues Natural Gas Mcf 7.3 Emergency 24 hours Ravolla 9/27/2023 2023 Flare Flared 85.9 MCF due to C-3 down due to post catalyst high temp Natural Gas Mcf 85.9 Maintenance 24 hours Farm 9/27/2023 2023 Flare Flared 1.3 MCF - nothing down Natural Gas Mcf 1.3 Maintenance 24 hours Ravolla 9/28/2023 2023 Flare Flared 692 MCF due to C-3 going down on post catalyst high temp Natural Gas Mcf 692 Maintenance 24 hours Farm 9/28/2023 2023 Flare Flared 27.5 MCF due to c-1 going down due to 2nd stage scrubber level high Natural Gas Mcf 27.5 Emergency 24 hours Ravolla 9/30/2023 2023 Flare Flared 20 MCF - nothing down Natural Gas Mcf 20 Maintenance 24 hours Farm 9/30/2023 2023 Flare Flared 2 mcf - nothing down Natural Gas Mcf 2 Maintenance 24 hours Ravolla 10/1/2023 2023 Flare Flared 21 MCF due to starting up C6 and leaving blow open for 10 minutes to let engine warm up Natural Gas Mcf 21 Maintenance 24 hours Farm 10/1/2023 2023 Flare Flared 1.5 MCF - nothing down Natural Gas Mcf 1.5 Maintenance 24 hours Ravolla 10/2/2023 2023 Flare Flared 3.4 mcf - nothing down Natural Gas Mcf 3.4 Maintenance 24 hours Farm 10/2/2023 2023 Flare Flared 1.2 MCF - nothing down Natural Gas Mcf 1.2 Maintenance 24 hours Ravolla 10/3/2023 2023 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 10/3/2023 2023 Flare Flared 1.45 MCF - nothing down Natural Gas Mcf 1.45 Maintenance 24 hours Farm 10/4/2023 2023 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Ravolla 10/4/2023 2023 Flare Flared 2 mcf - nothing down Natural Gas Mcf 2 Maintenance 24 hours Rabbit Gulch 10/4/2023 2023 Flare Flared 100 MCF due to prepping units for emissions testing, liquid mitigation was suspended which caused increased line pressures Natural Gas Mcf 100 Maintenance 24 hours Ravolla 10/5/2023 2023 Flare Flared 1206 MCF due to Farm Station being down due to installation of a new valve at Myton Slug Catcher Natural Gas Mcf 1206 Maintenance 24 hours Farm 10/5/2023 2023 Flare Flared 4177 MCF due to the station being down for 3 hours due to the installation of a new valve at Myton Slug Catcher. DOGM 8351 Natural Gas Mcf 4177 Maintenance 24 hours Rabbit Gulch 10/5/2023 2023 Flare Flared 90 MCF due to shut down of C-1 to adjust oil levels Natural Gas Mcf 90 Maintenance 24 hours Rabbit Gulch 10/6/2023 2023 Flare Flared 37 MCF due to shutdown of C-3 to change out diapers and check of belts Natural Gas Mcf 37 Maintenance 24 hours Farm 10/6/2023 2023 Flare Flared 3.73 MCF - nothing down Natural Gas Mcf 3.73 Maintenance 24 hours Ravolla 10/6/2023 2023 Flare Flared 13.6 mcf due to C-5 being down for service Natural Gas Mcf 13.6 Maintenance 24 hours Rabbit Gulch 10/7/2023 2023 Flare Flared 2.7 mcf due to sending and receiving line pigs Natural Gas Mcf 2.7 Maintenance 24 hours Farm 10/7/2023 2023 Flare Flared 1.21 MCF due to planned pipeline maintenance Natural Gas Mcf 1.21 Maintenance 24 hours Ravolla 10/7/2023 2023 Flare Flared 6.7 MCF due to C-2 shut down on no flow Natural Gas Mcf 6.7 Maintenance 24 hours Rabbit Gulch 10/8/2023 2023 Flare Flared 895 MCF due to C-3 going down due to mechanical issues Natural Gas Mcf 895 Maintenance 24 hours Farm 10/8/2023 2023 Flare Flared 1.33 MCF - nothing down Natural Gas Mcf 1.33 Maintenance 24 hours Ravolla 10/8/2023 2023 Flare Flared 2.2 MCF - nothing down Natural Gas Mcf 2.2 Maintenance 24 hours Farm 10/9/2023 2023 Flare Flared 2179 MCF on 10/9/2023 and an additional 4535 MCF on 10/10/2023, 10,389 MCF on 10/11/2023, 12,496 MCF on 10/12/2023, 8946 MCF on 10/13/2023, 12,112 MCF on 10/14/2023, 13750 MCF on 10/15/2023, 10533.2 MCF on 10/16/2023, 8422 MCF on 10/17/2023, 6549 MCF on 10/18/2023, 5173 MCF on 10/19/2023, 3863 MCF on 10/20/2023, 3771.6 MCF on 10/21/2023, 3886 MCF on 10/22/2023, 1531 MCF on 10/23/2023, and 1930 MCF on 10/24/2023 due to high discharge pressure from planned pipeline maintenance from Mountain West. DOGM 8354 Natural Gas Mcf 110065.8 Emergency 24 hours Ravolla 10/9/2023 2023 Flare Flared 21.3 MCF due to C-2 going down on no flow Natural Gas Mcf 21.3 Maintenance 24 hours Rabbit Gulch 10/9/2023 2023 Flare Flared 93 MCF due to South C-4 down for repairs causing high line pressure Natural Gas Mcf 93 Maintenance 24 hours Ravolla 10/10/2023 2023 Flare Flared 2.7 MCF - nothing down Natural Gas Mcf 2.7 Maintenance 24 hours Rabbit Gulch 10/10/2023 2023 Flare Flared 204 MCF - nothing down Natural Gas Mcf 204 Maintenance 24 hours Rabbit Gulch 10/11/2023 2023 Flare Flared 685 MCF due to high line pressure from South C-3 repairs Natural Gas Mcf 685 Repair 24 hours Ravolla 10/11/2023 2023 Flare Flared 65 MCF due to C-2 going down and high suction pressure Natural Gas Mcf 65 Maintenance 24 hours Rabbit Gulch 10/12/2023 2023 Flare Flared 657 MCF - nothing down Natural Gas Mcf 657 Maintenance 24 hours Ravolla 10/12/2023 2023 Flare Flared 214 MCF due to Unit C-2 going down Natural Gas Mcf 214 Maintenance 24 hours Ravolla 10/13/2023 2023 Flare Flared 869 MCF due to planned pipeline maintenance Natural Gas Mcf 869 Maintenance 24 hours Rabbit Gulch 10/13/2023 2023 Flare Flared 340 MCF due to South C-4 down for jacket water repairs causing high station pressures Natural Gas Mcf 340 Maintenance 24 hours Ravolla 10/14/2023 2023 Flare Flared 675 MCF due to high pressures from planned pipeline maintenance from Dominion.Natural Gas Mcf 675 Maintenance 24 hours Rabbit Gulch 10/14/2023 2023 Flare Flared 969 MCF - nothing down Natural Gas Mcf 969 Maintenance 24 hours Ravolla 10/15/2023 2023 Flare Flared 1095.2 MCF due to Dominion pipeline maintenance.Natural Gas Mcf 1095.2 Maintenance 24 hours Rabbit Gulch 10/15/2023 2023 Flare Flared 968 MCF due to high field pressure from pipeline maintenance.Natural Gas Mcf 968 Maintenance 24 hours Rabbit Gulch 10/16/2023 2023 Flare Flared 888 MCF due to high field pressure due to planned pipeline maintenance Natural Gas Mcf 888 Maintenance 24 hours Ravolla 10/16/2023 2023 Flare Flared 3700 MCF on 10/16/2023 and an additional 5789.8 MCF on 10/17/2023, 5124.6 MCF on 10/18/2023, and 3980 MCF on 10/19/23 due to Unit C-1 being down for planned maintenance and high pressure at Farm Station due to third-party pipeline maintenance. DOGM 8364 Natural Gas Mcf 18594.4 Maintenance 24 hours Rabbit Gulch 10/17/2023 2023 Flare Flared 40 MCF due to planned pipeline maintenance on Mountain West line.Natural Gas Mcf 40 Maintenance 24 hours Rabbit Gulch 10/18/2023 2023 Flare Flared 54 MCF due to planned pipeline maintenance on Mountain West line.Natural Gas Mcf 54 Maintenance 24 hours Rabbit Gulch 10/19/2023 2023 Flare Flared 205 MCF due to planned pipeline maintenance on Mountain West line.Natural Gas Mcf 205 Maintenance 24 hours Rabbit Gulch 10/20/2023 2023 Flare Flared 281 MCF due to planned pipeline maintenance on Mountain West line.Natural Gas Mcf 281 Maintenance 24 hours Ravolla 10/20/2023 2023 Flare Flared 73.5 MCF due to Farm being pressured up Natural Gas Mcf 73.5 Emergency 24 hours Ravolla 10/21/2023 2023 Flare Flared 1235.3 MCF due to C-3 down on ECM fault and C-1 down on 2nd stage scrubber level high Natural Gas Mcf 1235.3 Repair 24 hours Rabbit Gulch 10/21/2023 2023 Flare Flared 497 MCF due to planned pipeline maintenance on Mountain West line.Natural Gas Mcf 497 Maintenance 24 hours Rabbit Gulch 10/22/2023 2023 Flare Flared 945 MCF due to planned pipeline maintenance on Mountain West line.Natural Gas Mcf 945 Maintenance 24 hours Ravolla 10/22/2023 2023 Flare Flared 149.8 MCF due to C-1 down with bad wire in PLC Natural Gas Mcf 149.8 Maintenance 24 hours Rabbit Gulch 10/23/2023 2023 Flare Flared 717 MCF due to planned pipeline maintenance on Moutain West line.Natural Gas Mcf 717 Maintenance 24 hours Ravolla 10/23/2023 2023 Flare Flared 815.5 MCF due to C-3 down on ECM fault Natural Gas Mcf 815.5 Maintenance 24 hours Ravolla 10/24/2023 2023 Flare Flared 653 MCF due to C-2 and C-7 down for 2K service and C-3 down for maintenance Natural Gas Mcf 653 Maintenance 24 hours Rabbit Gulch 10/24/2023 2023 Flare Flared 615 MCF due to planned pipeline maintenance on Moutain West line.Natural Gas Mcf 615 Maintenance 24 hours Ravolla 10/25/2023 2023 Flare Flared 4.01 MCF - nothing down Natural Gas Mcf 4.01 Maintenance 24 hours Farm 10/25/2023 2023 Flare Flared 2.01 MCF - nothing down Natural Gas Mcf 2.01 Maintenance 24 hours Rabbit Gulch 10/25/2023 2023 Flare Flared 496 MCF due to planned pipeline maintenance on Moutain West line Natural Gas Mcf 496 Maintenance 24 hours Farm 10/26/2023 2023 Flare Flared 1392 MCF due to engine shut down to low suction and high load Natural Gas Mcf 1392 Emergency 24 hours Ravolla 10/26/2023 2023 Flare Flared 111 MCF due to Farm units going down and C-5 high discharge pressure and no flow Natural Gas Mcf 111 Emergency 24 hours Rabbit Gulch 10/26/2023 2023 Flare Flared 263 MCF due to C-2 going down due to low compressor oil Natural Gas Mcf 263 Emergency 24 hours Farm 10/27/2023 2023 Flare Flared 1536 MCF due to producer momentarily reducing flow into the station causing Units C-1, C-2, C-4, C-5, and C- 6 to go down for 45 minutes on low suction. DOGM 8371 Natural Gas Mcf 1536 Emergency 24 hours Ravolla 10/27/2023 2023 Flare Flared 460 MCF due to C-5 going down due to no flow and high suction pressure Natural Gas Mcf 460 Emergency 24 hours Rabbit Gulch 10/27/2023 2023 Flare Flared 220 MCF - nothing down Natural Gas Mcf 220 Maintenance 24 hours Farm 10/28/2023 2023 Flare Flared 1.37 MCF - nothing down Natural Gas Mcf 1.37 Maintenance 24 hours Ravolla 10/28/2023 2023 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Rabbit Gulch 10/28/2023 2023 Flare Flared 87 MCF - nothing down Natural Gas Mcf 87 Maintenance 24 hours Rabbit Gulch 10/29/2023 2023 Flare Flared 2 mcf - nothing down Natural Gas Mcf 2 Maintenance 24 hours Ravolla 10/30/2023 2023 Flare Flared 1.8 mcf - Nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Farm 10/30/2023 2023 Flare Flared 84 MCF due to C-6 and C-2 going down due to 2nd stage scrubber level high Natural Gas Mcf 84 Emergency 24 hours Rabbit Gulch 10/30/2023 2023 Flare Flared 100 MCF due to C-3 going down due to control pannel issues Natural Gas Mcf 100 Emergency 24 hours Farm 10/31/2023 2023 Flare Flared 12 MCF - nothing down Natural Gas Mcf 12 Maintenance 24 hours Rabbit Gulch 10/31/2023 2023 Flare Flared 326 MCF due to C-2 down for scheduled 2K PM Natural Gas Mcf 326 Maintenance 24 hours Rabbit Gulch 11/1/2023 2023 Flare Flared 1348 MCF due to C-3 down on 1 and 3 no flow Natural Gas Mcf 1348 Emergency 24 hours Ravolla 11/1/2023 2023 Flare Flared 22 MCF due to C-1 shutdown for gas leak and C-6 shutdown to plug a cooler tube Natural Gas Mcf 22 Emergency 24 hours Farm 11/1/2023 2023 Flare Flared 330.6 MCF due to C-2 going down on compressor vibration trans high and C-5 down on low engine speed Natural Gas Mcf 330.6 Emergency 24 hours Rabbit Gulch 11/2/2023 2023 Flare Flared 1997 MCF due to Unit C-3 being down on no flo and the alarm didn't sent. DOGM 8374 Natural Gas Mcf 1997 Emergency 24 hours Ravolla 11/2/2023 2023 Flare Flared 4.5 MCF - nothing down Natural Gas Mcf 4.5 Maintenance 24 hours Farm 11/2/2023 2023 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Rabbit Gulch 11/3/2023 2023 Flare Flared 990 MCF due to units being down for 45 minutes due to no/low flow Natural Gas Mcf 990 Emergency 24 hours Ravolla 11/3/2023 2023 Flare Flared 158.2 MCF due to C-3 down on post cat temp high Natural Gas Mcf 158.2 Emergency 24 hours Farm 11/3/2023 2023 Flare Flared 1052 MCF due to C-3 down on low compressor oil pressure and C-5 down on high coolant temp Natural Gas Mcf 1052 Emergency 24 hours Ravolla 11/4/2023 2023 Flare Flared 227.4 MCF due to C-3 going down on low compressor oil Natural Gas Mcf 227.4 Emergency 24 hours Farm 11/4/2023 2023 Flare Flared 1638 MCF due to Unit C-3 going down due to low compressor oil pressure. DOGM 8377 Natural Gas Mcf 1638 Emergency 24 hours Rabbit Gulch 11/4/2023 2023 Flare Flared 529 MCF due to high station pressure Natural Gas Mcf 529 Emergency 24 hours Ravolla 11/5/2023 2023 Flare Flared 10.5 MCF - nothing down Natural Gas Mcf 10.5 Maintenance 24 hours Farm 11/5/2023 2023 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Rabbit Gulch 11/5/2023 2023 Flare Flared 254 MCF due to high station pressure Natural Gas Mcf 254 Emergency 24 hours Ravolla 11/6/2023 2023 Flare Flared 2.1 MCF - nothing down Natural Gas Mcf 2.1 Emergency 24 hours Farm 11/6/2023 2023 Flare Flared 1.3 MCF - nothing down Natural Gas Mcf 1.3 Emergency 24 hours Rabbit Gulch 11/6/2023 2023 Flare Flared 1.7 MCF due to high station pressure Natural Gas Mcf 1.7 Emergency 24 hours Ravolla 11/7/2023 2023 Flare Flared 4.6 MCF - nothing down Natural Gas Mcf 4.6 Maintenance 24 hours Farm 11/7/2023 2023 Flare Flared 2.6 MCF - nothing down Natural Gas Mcf 2.6 Maintenance 24 hours Rabbit Gulch 11/7/2023 2023 Flare Flared 20 MCF - nothing down Natural Gas Mcf 20 Maintenance 24 hours Farm 11/8/2023 2023 Flare Flared 1.1 MCF - nothing down Natural Gas Mcf 1.1 Maintenance 24 hours Ravolla 11/8/2023 2023 Flare Flared 3.4 MCF - nothing down Natural Gas Mcf 3.4 Maintenance 24 hours Ravolla 11/9/2023 2023 Flare Flared 1.9 MCF - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Farm 11/9/2023 2023 Flare Flared 2.9 MCF - nothing down Natural Gas Mcf 2.9 Maintenance 24 hours Rabbit Gulch 11/9/2023 2023 Flare Flared 224 MCF - C1 down 2.25 hrs unplanned/low coolant in auxillary system.Natural Gas Mcf 224 Emergency 24 hours Farm 11/10/2023 2023 Flare Flared 106 MCF - C4, C5, and C6 shutting down on high suction/load pressure.Natural Gas Mcf 106 Emergency 24 hours Rabbit Gulch 11/10/2023 2023 Flare Flared 56 MCF - nothing down Natural Gas Mcf 56 Maintenance 24 hours Ravolla 11/11/2023 2023 Flare Flared 3.3 MCF - nothing down Natural Gas Mcf 3.3 Maintenance 24 hours Farm 11/11/2023 2023 Flare Flared 358 MCF - Lost C5 and C6 on high load pressure. Lst C6 multiple times on under speed. Left down and started C3 instead.Natural Gas Mcf 358 Repair 24 hours Rabbit Gulch 11/11/2023 2023 Flare Flared 1274 MCF - C3 down 1.5 hours unplanned. No flow 1 and 3.Natural Gas Mcf 1274 Repair 24 hours Rabbit Gulch 11/12/2023 2023 Flare Flared 489 MCF - nothing down Natural Gas Mcf 489 Maintenance 24 hours Farm 11/12/2023 2023 Flare Flared 2.2 MCF - nothing down Natural Gas Mcf 2.2 Maintenance 24 hours Ravolla 11/12/2023 2023 Flare Flared 21.5 MCF due to C-5 down due to high suction pressure Natural Gas Mcf 21.5 Emergency 24 hours Farm 11/13/2023 2023 Flare Flared 1.2 MCF - nothing down Natural Gas Mcf 1.2 Maintenance 24 hours Ravolla 11/13/2023 2023 Flare Flared 1.9 MCF - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Rabbit Gulch 11/13/2023 2023 Flare Flared 675 MCF - due to C2 down 2.75 hrs unplanned/low compressor oil Natural Gas Mcf 675 Emergency 24 hours Ravolla 11/14/2023 2023 Flare Flared 33.8 MCF - C3 went down on low comp oil level and got a 2k Natural Gas Mcf 33.8 Maintenance 24 hours Farm 11/14/2023 2023 Flare Flared 59.3 MCF - due to C6 went down on low diff pressure Natural Gas Mcf 59.3 Maintenance 24 hours Rabbit Gulch 11/14/2023 2023 Flare Flared 615 MCF - nothing down Natural Gas Mcf 615 Maintenance 24 hours Farm 11/15/2023 2023 Flare Flared 1677.3 MCF - due to C6 was down for 3 hours on low differential pressure, producers adjusting line pressures contributed to C6 going down. DOGM 8382 Natural Gas Mcf 1677.3 Emergency 24 hours Ravolla 11/15/2023 2023 Flare Flared 2.2 MCF - C5 was down for 1 hour on high 1st stage discharge pressure Natural Gas Mcf 2.2 Maintenance 24 hours Rabbit Gulch 11/15/2023 2023 Flare Flared 366 MCF - no units are down - station pressure is 39 - high station pressure Natural Gas Mcf 366 Maintenance 24 hours Ravolla 11/16/2023 2023 Flare Flared 9.6 MCF - nothing down Natural Gas Mcf 9.6 Maintenance 24 hours Farm 11/16/2023 2023 Flare Flared 2472.2 MCF - due to C5 went down for 3 hours on high exhaust temp cyl 9. DOGM 8383.Natural Gas Mcf 2472.2 Repair 24 hours Rabbit Gulch 11/16/2023 2023 Flare Flared 366 MCF - due to Farm C6 being down for repairs, causing high station pressure.Natural Gas Mcf 366 Maintenance 24 hours Rabbit Gulch 11/17/2023 2023 Flare Flared 442 MCF - due to Farm C6 being down for repairs, causing high station pressure.Natural Gas Mcf 442 Maintenance 24 hours Ravolla 11/17/2023 2023 Flare Flared 1.1 MCF - nothing down Natural Gas Mcf 1.1 Maintenance 24 hours Farm 11/17/2023 2023 Flare Flared 4.9 MCF - nothing down Natural Gas Mcf 4.9 Maintenance 24 hours Rabbit Gulch 11/18/2023 2023 Flare Flared 51 MCF - due to Farm C6 being down for repairs, causing high station pressure.Natural Gas Mcf 51 Maintenance 24 hours Ravolla 11/18/2023 2023 Flare Flared 1.1 MCF - nothing down Natural Gas Mcf 1.1 Maintenance 24 hours Farm 11/18/2023 2023 Flare Flared 4.9 MCF - nothing down Natural Gas Mcf 4.9 Maintenance 24 hours Ravolla 11/19/2023 2023 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Farm 11/19/2023 2023 Flare Flared 1.5 MCF - nothing down Natural Gas Mcf 1.5 Maintenance 24 hours Rabbit Gulch 11/19/2023 2023 Flare Flared 562 MCF - due to C2 being down on 2 & 4 cylinder lubricator no flow. C3 down on 1 & 3 cylinder lubricator no flo.Natural Gas Mcf 562 Repair 24 hours Rabbit Gulch 11/22/2023 2023 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Ravolla 11/22/2023 2023 Flare Flared 7.7 MCF - nothing down Natural Gas Mcf 7.7 Maintenance 24 hours Farm 11/22/2023 2023 Flare Flared 4.8 MCF - nothing down Natural Gas Mcf 4.8 Maintenance 24 hours Farm 11/23/2023 2023 Flare Flared 27 MCF - due to lost c5 on over speed due to faulty sensor on engine. Natural Gas Mcf 27 Repair 24 hours Ravolla 11/23/2023 2023 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Ravolla 11/25/2023 2023 Flare Flared 33 MCF - due to C5 being down on right bank no flow. C6 down for cooler tube repair.Natural Gas Mcf 33 Repair 24 hours Farm 11/26/2023 2023 Flare Flared 3.6 MCF - nothing down Natural Gas Mcf 3.6 Maintenance 24 hours Ravolla 11/26/2023 2023 Flare Flared 44 MCF - due to C6 going back down for cooler tube leak and losing C4 Natural Gas Mcf 44 Repair 24 hours Rabbit Gulch 11/26/2023 2023 Flare Flared 644 MCF - due to C1 down 7 hours. Unplanned/ engine oil leak Natural Gas Mcf 644 Emergency 24 hours Ravolla 11/27/2023 2023 Flare Flared 33 MCF - due to C6 down on cooler tube leak.Natural Gas Mcf 33 Repair 24 hours Farm 11/27/2023 2023 Flare Flared 4.65 MCF - nothing down Natural Gas Mcf 4.65 Maintenance 24 hours Rabbit Gulch 11/27/2023 2023 Flare Flared 644 MCF - C1 down on oil leak Natural Gas Mcf 644 Repair 24 hours Farm 11/28/2023 2023 Flare Flared 2.24MCF - due to C3 and C4 down for maintenance for 2 hours Natural Gas Mcf 2.24 Maintenance 24 hours Ravolla 11/28/2023 2023 Flare Flared 116.1 MCF - due to high pressure with Farm units down Natural Gas Mcf 116.1 Maintenance 24 hours Rabbit Gulch 11/28/2023 2023 Flare Flared 2615 MCF - due to C3 recycle valve malfunctioned and stuck open. DOGM 8389 Natural Gas Mcf 2615 Repair 24 hours Rabbit Gulch 11/29/2023 2023 Flare Flared 2872 MCF - due to pipeline going to West station froze causing high pressure at the other stations. DOGM 8390.Natural Gas Mcf 2872 Emergency 24 hours Ravolla 11/29/2023 2023 Flare Flared 1248.3 MCF - due to farm station losing unit and pressuring up Ravolla.Natural Gas Mcf 1248.3 Emergency 24 hours Farm 11/29/2023 2023 Flare Flared 3997.8 MCF - due to C2 down for half an hour on 2nd statge scrubber level high. C4, 6 was down for 5 hours on 2nd stage scrubber level high, C1 was down for 1 hour on 2nd stage scrubber high. High pressure dump line from discharge scrubber stuck open preventing 2nd stages from dumping. DOGM 8391 Natural Gas Mcf 3997.8 Emergency 24 hours Rabbit Gulch 11/30/2023 2023 Flare Flared 228 MCF - due to units down at farm station for scheduled PMs. Ravolla C5 down for compressor repairs Natural Gas Mcf 228 Maintenance 24 hours Ravolla 11/30/2023 2023 Flare Flared 989.6 MCF - due to Farm loosing unit and pressuring up Ravolla Natural Gas Mcf 989.6 Emergency 24 hours Farm 11/30/2023 2023 Flare Flared 4942.2 MCF – due to C1 & C6 was down for 4 hours on 2nd stage scrubber level high due to station discharge scrubber automatic dump valve hung open from hydrates causing HP drain system to pressure up preventing Units 2nd stage from dumping. DOGM: 8392 Natural Gas Mcf 4942.2 Emergency 24 hours Ravolla 12/1/2023 2023 Flare Flared 133.3 MCF - due to blow down was open when trying to start C5 Natural Gas Mcf 133.3 Emergency 24 hours Farm 12/1/2023 2023 Flare Flared 2.9 MCF - nothing down Natural Gas Mcf 2.9 Maintenance 24 hours Ravolla 12/2/2023 2023 Flare Flared 408 MCF - due to blow down was open while the oil was warming up from starting C6 Natural Gas Mcf 408 Emergency 24 hours Farm 12/2/2023 2023 Flare Flared 4.8 MCF - nothing down Natural Gas Mcf 4.8 Maintenance 24 hours Rabbit Gulch 12/2/2023 2023 Flare Flared 54 MCF - due to C2 down on low compressor oil level Natural Gas Mcf 54 Repair 24 hours Ravolla 12/3/2023 2023 Flare Flared 1156.7 MCF - due to station pressured up due to losing 5 units at Farm Natural Gas Mcf 1156.7 Emergency 24 hours Farm 12/3/2023 2023 Flare Flared 3597.3 MCF - due to lost 5 units due to Mountain West's slam valve closing at Myton due to high H2S. DOGM 8395. Unplanned.Natural Gas Mcf 3597.3 Emergency 24 hours Ravolla 12/4/2023 2023 Flare Flared 444.1 MCF - due to C6 at ravolla started and had to let the blow down be open for 2 hours while the compressor oil warmed up.Natural Gas Mcf 444.1 Maintenance 24 hours Farm 12/4/2023 2023 Flare Flared 138.6 MCF - nothing down Natural Gas Mcf 138.6 Maintenance 24 hours Rabbit Gulch 12/4/2023 2023 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Ravolla 12/5/2023 2023 Flare Flared 3 MCF - due to purge gas Natural Gas Mcf 3 Maintenance 24 hours Farm 12/5/2023 2023 Flare Flared 88 MCF - due to purge gas Natural Gas Mcf 88 Maintenance 24 hours Ravolla 12/6/2023 2023 Flare Flared 150.5 MCF - due to high field pressure from Farm station shutdown Natural Gas Mcf 150.5 Emergency 24 hours Farm 12/6/2023 2023 Flare Flared 810.67 MCF - due to all engines going down on low suction and high load, investigating XCL line valve malfunction. Station recycle valve was blocked in.Natural Gas Mcf 810.67 Emergency 24 hours Rabbit Gulch 12/6/2023 2023 Flare Flared 809 MCF - due to valve testing. Planned.Natural Gas Mcf 809 Maintenance 24 hours Ravolla 12/7/2023 2023 Flare Flared 13.84 MCF - nothing down Natural Gas Mcf 13.84 Maintenance 24 hours Farm 12/7/2023 2023 Flare Flared 43.73 MCF - nothing down Natural Gas Mcf 43.73 Maintenance 24 hours Farm 12/8/2023 2023 Flare Flared 896 MCF - due to station going down with high 3rd stage discharge pressure Natural Gas Mcf 896 Emergency 24 hours Ravolla 12/8/2023 2023 Flare Flared 187 MCF - due to high field pressure with Farm being down Natural Gas Mcf 187 Emergency 24 hours Rabbit Gulch 12/8/2023 2023 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 12/9/2023 2023 Flare Flared 1432 MCF - due to all units going down from PSD from contact tower pressure sending unit malfuctioning.Natural Gas Mcf 1432 Emergency 24 hours Ravolla 12/9/2023 2023 Flare Flared 1460 MCF - due to high field pressure from Farm being down Natural Gas Mcf 1460 Emergency 24 hours Farm 12/10/2023 2022 Flare Flared 746 Mcf due to C-2 unscheduled down on EMS shutdown and C-1 down 1.5 hours on low speed SD.Natural Gas Mcf 746 Maintenance 24 hours Farm 12/10/2023 2023 Flare Flared 1.78 MCF - nothing down Natural Gas Mcf 1.78 Maintenance 24 hours Ravolla 12/10/2023 2023 Flare Flared 7.6 MCF - nothing down Natural Gas Mcf 7.6 Maintenance 24 hours Rabbit Gulch 12/10/2023 2023 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 12/11/2023 2023 Flare Flared 1.64 MCF - nothing down Natural Gas Mcf 1.64 Maintenance 24 hours Ravolla 12/11/2023 2023 Flare Flared 3.4 MCF - nothing down Natural Gas Mcf 3.4 Maintenance 24 hours Farm 12/12/2023 2023 Flare Flared 2.09 MCF- nothing down Natural Gas Mcf 2.09 Maintenance 24 hours Ravolla 12/12/2023 2023 Flare Flared 1.9 MCF - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Rabbit Gulch 12/13/2023 2023 Flare Flared 139 MCF - due to C2 down for schedueld calibration Natural Gas Mcf 139 Maintenance 24 hours Ravolla 12/13/2023 2023 Flare Flared 417.5 MCF - due to station pressured up from losing units at Farm Natural Gas Mcf 417.5 Emergency 24 hours Farm 12/13/2023 2023 Flare Flared 2651.2 MCF - due to unschedueld operational, Lost 5 units for 4 hours on 3rd stage discharge pressure high due to mountain wests block valve closing for unknown reason. DOGM 8403.Natural Gas Mcf 2651.2 Emergency 24 hours Rabbit Gulch 12/14/2023 2023 Flare Flared 12 MCF - due to farm station went down, caused high station pressure.Natural Gas Mcf 12 Emergency 24 hours Ravolla 12/14/2023 2023 Flare Flared 449.4 MCF - due to station pressured up from loosing units at Farm Natural Gas Mcf 449.4 Emergency 24 hours Farm 12/14/2023 2023 Flare Flared 2417.7 MCF - due to lost all units on 3rd stage dischare pressure high due to Myton inlet block valve closing after high level switch was tagged from pipeline maintenance liquids. Unplanned. DOGM 8407.Natural Gas Mcf 2417.7 Emergency 24 hours Rabbit Gulch 12/15/2023 2023 Flare Flared 148 MCF - due to south C1 down causing high station pressure Natural Gas Mcf 148 Maintenance 24 hours Ravolla 12/15/2023 2023 Flare Flared 590.3 MCF - due to C6 blow down was open for 2.5 hours for warm up Natural Gas Mcf 590.3 Maintenance 24 hours Farm 12/15/2023 2023 Flare Flared 1.4 MCF - nothing down Natural Gas Mcf 1.4 Maintenance 24 hours Ravolla 12/16/2023 2023 Flare Flared 192.7 MCF - due to C6 blow down was open for 2.5 hours for warm up C1 was down for 5 hours on compressor no flow 1 & 3.Natural Gas Mcf 192.7 Repair 24 hours Farm 12/16/2023 2023 Flare Flared 1.8 mcf - Nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Ravolla 12/17/2023 2023 Flare Flared 2.3 MCF - nothing down Natural Gas Mcf 2.3 Maintenance 24 hours Farm 12/17/2023 2023 Flare Flared 18 MCF - nothing down Natural Gas Mcf 18 Maintenance 24 hours Rabbit Gulch 12/17/2023 2023 Flare Flared 984 MCF - due to pipeline maintenance station was already high and units didn't recycle Natural Gas Mcf 984 Maintenance 24 hours Rabbit Gulch 12/18/2023 2023 Flare Flared 957 MCF - C3 went down on 2 & 4 no flow, miscommunication between plant and field crew delayed the alarm notification for a quick response Natural Gas Mcf 957 Maintenance 24 hours Ravolla 12/18/2023 2023 Flare Flared 134 MCF - due to shutdown unit so Merver could do their valve testing Natural Gas Mcf 134 Maintenance 24 hours Farm 12/18/2023 2023 Flare Flared 4.5 MCF - nothing down Natural Gas Mcf 4.5 Maintenance 24 hours Ravolla 12/19/2023 2023 Flare Flared 17.5 MCF - due to shutting down units for valve testing.Natural Gas Mcf 17.5 Maintenance 24 hours Farm 12/19/2023 2023 Flare Flared 2.5 mcf - nothing down Natural Gas Mcf 2.5 Maintenance 24 hours Rabbit Gulch 12/19/2023 2023 Flare Flared 1788 MCF - due to C3 down for 16 hours. Unplanned. No flow 2 and 4, miscommunication between gas plant control room personnel and field liquid mitigator personnel resulted in unit not getting put back online in a timely manner. DOGM: 8413.Natural Gas Mcf 1788 Emergency 24 hours Farm 12/20/2023 2023 Flare Flared 2589 MCF - due to Mountain west shutting in block valve due to detected spike in H2S. Unplanned. No investigation needed. DOGM 8415.Natural Gas Mcf 2589 Emergency 24 hours Ravolla 12/20/2023 2023 Flare Flared 593 MCF due to high field pressure with Farm being down.Natural Gas Mcf 593 Emergency 24 hours Rabbit Gulch 12/20/2023 2023 Flare Flared 2435 MCF - due to C3 being down. Unplanned new battery failed on no flow 2 and 4. DOGM 8416.Natural Gas Mcf 2435 Repair 24 hours Ravolla 12/20/2023 2023 Flare Flared 62 MCF due to high field pressure from Farm units down Natural Gas Mcf 62 Emergency 24 hours Farm 12/20/2023 2023 Flare Flared 620 MCF - due to C1 and C2 down for valve testing Natural Gas Mcf 620 Maintenance 24 hours Rabbit Gulch 12/21/2023 2023 Flare Flared 1544 MCF - due to producers start up a new well causing unexpected high operational field pressures, nothing down. DOGM 8417 Natural Gas Mcf 1544 Emergency 24 hours Ravolla 12/22/2023 2023 Flare Flared 13.6 MCF - nothing down Natural Gas Mcf 13.6 Maintenance 24 hours Farm 12/22/2023 2023 Flare Flared 1987 MCF - due to Scheduled operational maintenance, Mercer Valve performing the annual PSV testing shutting down one unit at a time. DOGM 8418 Natural Gas Mcf 1987 Maintenance 24 hours Rabbit Gulch 12/22/2023 2023 Flare Flared 1901 MCF - due to high field pressures and C3 down 2.5 hours/unplanned no flow 1 and 3 pro-flo lubrication monitor failure, mechanical. DOGM 8417.Natural Gas Mcf 1901 Emergency 24 hours Ravolla 12/23/2023 2023 Flare Flared 55 MCF - due to C6 down on high discharge pressure Natural Gas Mcf 55 Emergency 24 hours Farm 12/23/2023 2023 Flare Flared 0.96 MCF - nothing down Natural Gas Mcf 0.96 Maintenance 24 hours Rabbit Gulch 12/23/2023 2023 Flare Flared 1267 MCF - nothing down Natural Gas Mcf 1267 Maintenance 24 hours Ravolla 12/24/2023 2023 Flare Flared 1.9 MCF - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Farm 12/24/2023 2023 Flare Flared 0.89 MCF - nothing down Natural Gas Mcf 0.89 Maintenance 24 hours Rabbit Gulch 12/24/2023 2023 Flare Flared 129 MCF - due to C3 down 1.25 hrs. Unplanned. No flow 2 and 4.Natural Gas Mcf 129 Repair 24 hours Ravolla 12/25/2023 2023 Flare Flared 1.8 MCF - nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Farm 12/25/2023 2023 Flare Flared 2.02 MCF- nothing down Natural Gas Mcf 2.02 Maintenance 24 hours Ravolla 12/26/2023 2023 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 12/26/2023 2023 Flare Flared 268 MCF - due to C2 being down for an hour for Mercer Valve testing.Natural Gas Mcf 268 Maintenance 24 hours Ravolla 12/27/2023 2023 Flare Flared 5.2 MCF - due to C2 was down for half an hour on ECM fault (high coolant temp)Natural Gas Mcf 5.2 Repair 24 hours Farm 12/27/2023 2023 Flare Flared 14.7 MCF- nothing down Natural Gas Mcf 14.7 Maintenance 24 hours Rabbit Gulch 12/27/2023 2023 Flare Flared 6 MCF - due to C3 was shutdown for 2 & 4 no flow repairs Natural Gas Mcf 6 Repair 24 hours Ravolla 12/28/2023 2023 Flare Flared 1.9 MCF - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Farm 12/28/2023 2023 Flare Flared 17.2 MCF - nothing down Natural Gas Mcf 17.2 Maintenance 24 hours Ravolla 12/29/2023 2023 Flare Flared 3.8 MCF - nothing down Natural Gas Mcf 3.8 Maintenance 24 hours Farm 12/29/2023 2023 Flare Flared 2244.5 MCF - due to lost 4 units during scheduled pipeline maintenance due to pressure swing on inlet gas. Units without recycling capability went down causing a spike in pressure on inlet header. Due to inadequate design and installation of the station recycle valve the station couldn't recycle to keep all units properly fed cuasing an operational upset. DOGM 8424 Natural Gas Mcf 2244.5 Emergency 24 hours Rabbit Gulch 12/30/2023 2023 Flare Flared 1 MCF - adjusting suction pressure. Nothing down. High station pressure Natural Gas Mcf 1 Maintenance 24 hours Ravolla 12/30/2023 2023 Flare Flared 1.1 MCF - nothing down Natural Gas Mcf 1.1 Maintenance 24 hours Farm 12/30/2023 2023 Flare Flared 1976.9 MCF - due to C5 down on low engines speed, C6 down on high engine load. Operational. DOGM 8425 Natural Gas Mcf 1976.9 Emergency 24 hours Ravolla 12/31/2023 2023 Flare Flared 31.5 mcf - nothing down Natural Gas Mcf 31.5 Maintenance 24 hours Farm 12/31/2023 2023 Flare Flared 184 MCF - due to C2 down on 3rd stage high discharge pressure.Natural Gas Mcf 184 Repair 24 hours Rabbit Gulch 12/31/2023 2023 Flare Flared 324 MCF- due to pipeline pressure has been fluctuating from producers Natural Gas Mcf 324 Maintenance 24 hours Farm 1/1/2024 2024 Flare Flared 1089.1 MCF - due to C2 down on 3rd stage discharge pressure high, C6 down on engine load high Natural Gas Mcf 1089.1 Emergency 24 hours Rabbit Gulch 1/1/2024 2024 Flare Flared 503 MCF - due to South C2 down for repairs causing high station pressure Natural Gas Mcf 503 Emergency 24 hours Ravolla 1/1/2024 2024 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Farm 1/2/2024 2024 Flare Flared 1347 MCF - due to lost 5 units on high engine load.Natural Gas Mcf 1347 Emergency 24 hours Rabbit Gulch 1/2/2024 2024 Flare Flared 28 MCF - nothing down Natural Gas Mcf 28 Maintenance 24 hours Ravolla 1/2/2024 2024 Flare Flared 193.5 MCF - due to C6 blow down was open for 3 hours while compressor oil got warm.Natural Gas Mcf 193.5 Repair 24 hours Farm 1/3/2024 2024 Flare Flared 1075 MCF - due to C6 going down on low suction and shutting down C1. To raise suction pressure or help with slug catcher freeze off.Natural Gas Mcf 1075 Emergency 24 hours Rabbit Gulch 1/3/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Ravolla 1/3/2024 2024 Flare Flared 23.7 MCF - nothing down Natural Gas Mcf 23.7 Maintenance 24 hours Farm 1/4/2024 2024 Flare Flared 2907 MCF - due to unscheduled down time.C6 being down for piston, cylinder liner, and head work. DOGM 8430 Natural Gas Mcf 2907 Repair 24 hours Rabbit Gulch 1/4/2024 2024 Flare Flared 39 MCF - nothing down Natural Gas Mcf 39 Maintenance 24 hours Ravolla 1/4/2024 2024 Flare Flared 76 MCF - due to C5 going down on high 1st stage suction, and C7 going down on low comp oil.Natural Gas Mcf 76 Repair 24 hours Farm 1/5/2024 2024 Flare Flared 4256 MCF - due to unscheduled down time.C6 being down for piston, cylinder liner, and head work. DOGM 8430 Natural Gas Mcf 4256 Repair 24 hours Rabbit Gulch 1/5/2024 2024 Flare Flared 135 MCF - nothing down Natural Gas Mcf 135 Maintenance 24 hours Ravolla 1/5/2024 2024 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 1/6/2024 2024 Flare Flared 2.8 MCF - nothing down Natural Gas Mcf 2.8 Maintenance 24 hours Ravolla 1/6/2024 2024 Flare Flared 1.9 MCF - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Farm 1/7/2024 2024 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Rabbit Gulch 1/7/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Ravolla 1/7/2024 2024 Flare Flared 10 MCF - nothing down Natural Gas Mcf 10 Maintenance 24 hours Farm 1/8/2024 2024 Flare Flared 297 MCF - due to C3, C4, C5 going down on low suction due to station inlet valve shutting by operator to try and sweep in pipeline liquids from secondary field inlet line.Natural Gas Mcf 297 Emergency 24 hours Ravolla 1/8/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Farm 1/9/2024 2024 Flare Flared 1653 MCF - due to C1 and C2 down for planned maintenance. DOGM 8434 Natural Gas Mcf 1653 Maintenance 24 hours Ravolla 1/9/2024 2024 Flare Flared 3.7 MCF - nothing down Natural Gas Mcf 3.7 Maintenance 24 hours Farm 1/10/2024 2024 Flare Flared 1154.5 MCF - due to last all units for 1 hour due to a utility power outage Natural Gas Mcf 1154.5 Emergency 24 hours Ravolla 1/10/2024 2024 Flare Flared 104.6 MCF - due to the power outage at Farm Natural Gas Mcf 104.6 Emergency 24 hours Farm 1/11/2024 2024 Flare Flared 5.5 MCF - nothing down Natural Gas Mcf 5.5 Maintenance 24 hours Rabbit Gulch 1/11/2024 2024 Flare Flared 1.8 MCF - due to sending/receiving pigs Natural Gas Mcf 1.8 Maintenance 24 hours Ravolla 1/11/2024 2024 Flare Flared 88.8 MCF - due to C5 starting up after getting mechanical work done Natural Gas Mcf 88.8 Maintenance 24 hours Farm 1/12/2024 2024 Flare Flared 3 MCF - nothing down Natural Gas Mcf 3 Maintenance 24 hours Ravolla 1/12/2024 2024 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Farm 1/13/2024 2024 Flare Flared 2049 MCF - due to station PSD (high H2S) due to the analyzer faulted on lead acetate tape malfunction on the ultrafab treating system. New roll of tap use installed and problem cleared. Operational. Unplanned. DOGM 8437 Natural Gas Mcf 2049 Repair 24 hours Ravolla 1/13/2024 2024 Flare Flared 449 MCF - due to C6 blow down was open for 3 hours while it warmed up, C3 was down for 2 on ECM fault (high engine oil temp)Natural Gas Mcf 449 Repair 24 hours Farm 1/15/2024 2024 Flare Flared 206.5 MCF - due to C2 down for 2nd stage scrubber level high Natural Gas Mcf 206.5 Repair 24 hours Ravolla 1/15/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Rabbit Gulch 1/16/2024 2024 Flare Flared 3.2 MCF - nothing down Natural Gas Mcf 3.2 Maintenance 24 hours Farm 1/17/2024 2024 Flare Flared 4.1 MCF - nothing down Natural Gas Mcf 4.1 Maintenance 24 hours Ravolla 1/17/2024 2024 Flare Flared 19 MCF - nothing down Natural Gas Mcf 19 Maintenance 24 hours Farm 1/18/2024 2024 Flare Flared 1033 MCF - due to C6 down on high second stage discharge pressure due to freeze off inside the recycle valve and losing C4 due to over draw on the power distribution block.Natural Gas Mcf 1033 Repair 24 hours Ravolla 1/18/2024 2024 Flare Flared 13.6 MCF - nothing down Natural Gas Mcf 13.6 Maintenance 24 hours Farm 1/19/2024 2024 Flare Flared 2432 MCF - due to inlet gas volumes sudden increase from producers after returning to normal production from the previous couple days of reduced volumes due to winter storm. Producers failed to notify Operations of the increase, therefore the available Natural Gas Mcf 2432 Emergency 24 hours Rabbit Gulch 1/19/2024 2024 Flare Flared 47 MCF - due to C1 down on high discharge pressure Natural Gas Mcf 47 Maintenance 24 hours Ravolla 1/19/2024 2024 Flare Flared 69 MCF - due to C6 warming up and going down multiple times on no flow.Natural Gas Mcf 69 Repair 24 hours Farm 1/20/2024 2024 Flare Flared 1.5 MCF - nothing down Natural Gas Mcf 1.5 Maintenance 24 hours Ravolla 1/20/2024 2024 Flare Flared 1.9 MCF - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Farm 1/21/2024 2024 Flare Flared 0.53 MCF - nothing down Natural Gas Mcf 0.53 Maintenance 24 hours Rabbit Gulch 1/21/2024 2024 Flare Flared 2 MCF - due to C1 unscheduled down on high 3rd stage discharge pressure.Natural Gas Mcf 2 Repair 24 hours Ravolla 1/21/2024 2024 Flare Flared 3.2 MCF - nothing down Natural Gas Mcf 3.2 Maintenance 24 hours Farm 1/22/2024 2024 Flare Flared 1063 MCF - due to high suction pressure with Ravolla being down due to plant ESD Natural Gas Mcf 1063 Maintenance 24 hours Rabbit Gulch 1/22/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Ravolla 1/22/2024 2024 Flare Flared 876 MCF - due to units going down from plant ESD Natural Gas Mcf 876 Maintenance 24 hours Farm 1/23/2024 2024 Flare Flared 0.1 MCF - nothing down Natural Gas Mcf 0.1 Maintenance 24 hours Rabbit Gulch 1/23/2024 2024 Flare Flared 11 MCF - due to C3 down on 2 & 4 no flow Natural Gas Mcf 11 Repair 24 hours Ravolla 1/23/2024 2024 Flare Flared 26.7 MCF - nothing down Natural Gas Mcf 26.7 Maintenance 24 hours Farm 1/24/2024 2024 Flare Flared 275.1 MCF - due to C6 was down on low suction Natural Gas Mcf 275.1 Repair 24 hours Rabbit Gulch 1/24/2024 2024 Flare Flared 605 MCF - due to C3 down on 2 & 4 no flow Natural Gas Mcf 605 Maintenance 24 hours Ravolla 1/24/2024 2024 Flare Flared 88 MCF - due to C6 blowdown was open for 2 hours while compressor warmed up Natural Gas Mcf 88 Maintenance 24 hours Farm 1/25/2024 2024 Flare Flared 1624.4 MCF - Due to scheduled maintenance on Units C3 & C4. DOGM 8451.Natural Gas Mcf 1624.4 Maintenance 24 hours Rabbit Gulch 1/25/2024 2024 Flare Flared 404 MCF - due to C2 scheduled maintenance Natural Gas Mcf 404 Maintenance 24 hours Ravolla 1/25/2024 2024 Flare Flared 20 MCF - due to C2 down on 3rd stage diff pressure Natural Gas Mcf 20 Maintenance 24 hours Farm 1/26/2024 2024 Flare Flared 2.1 MCF - nothing down Natural Gas Mcf 2.1 Maintenance 24 hours Rabbit Gulch 1/26/2024 2024 Flare Flared 79 MCF - due to C1 down on 3rd stage high discharge Natural Gas Mcf 79 Maintenance 24 hours Ravolla 1/26/2024 2024 Flare Flared 44.9 MCF - due to unit C4 down on high crank case pressure Natural Gas Mcf 44.9 Repair 24 hours Farm 1/27/2024 2024 Flare Flared 1.2 - nothing down Natural Gas Mcf 1.2 Maintenance 24 hours Rabbit Gulch 1/27/2024 2024 Flare Flared 1.4 MCF - nothing down Natural Gas Mcf 1.4 Maintenance 24 hours Ravolla 1/27/2024 2024 Flare Flared 106.4 MCF - due to C4 down for an hour on high crank case pressure Natural Gas Mcf 106.4 Repair 24 hours Farm 1/28/2024 2024 Flare Flared 1.2 MCF - nothing down Natural Gas Mcf 1.2 Maintenance 24 hours Ravolla 1/28/2024 2024 Flare Flared 2.8 MCF - nothing down Natural Gas Mcf 2.8 Maintenance 24 hours Farm 1/29/2024 2024 Flare Flared 1.2 MCF - nothing down Natural Gas Mcf 1.2 Maintenance 24 hours Ravolla 1/29/2024 2024 Flare Flared 1.9 MCF - nothing down Natural Gas Mcf 1.9 Maintenance 24 hours Rabbit Gulch 1/30/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Farm 1/31/2024 2024 Flare Flared 1.29 MCF - nothing down Natural Gas Mcf 1.29 Maintenance 24 hours Ravolla 1/31/2024 2024 Flare Flared 143 MCF - due to C1 shutdown for planned maintenance and C5 down while contractors bolted down wall inside fan shroud Natural Gas Mcf 143 Maintenance 24 hours Farm 2/1/2024 2024 Flare Flared 966 MCF - due to multiple units going down on high discharge pressure with Myton slug catcher block valve shutting.Natural Gas Mcf 966 Emergency 24 hours Ravolla 2/1/2024 2024 Flare Flared 112 MCF - due to high inlet pressure from Farm station units going down on high discharge pressure with Myton slug catcher block valve shutting.Natural Gas Mcf 112 Emergency 24 hours Farm 2/2/2024 2024 Flare Flared 85.8 MCF - due to planned maintenance for 8k service on C1 Natural Gas Mcf 85.8 Maintenance 24 hours Ravolla 2/2/2024 2024 Flare Flared 59 MCF - due to maintenance on engine oil auto fills on C4 Natural Gas Mcf 59 Repair 24 hours Farm 2/3/2024 2024 Flare Flared 1.12 MCF - nothing down Natural Gas Mcf 1.12 Maintenance 24 hours Rabbit Gulch 2/3/2024 2024 Flare Flared 239 MCF - due to scheduled downtime for repairs on C2 & C3 Natural Gas Mcf 239 Repair 24 hours Ravolla 2/3/2024 2024 Flare Flared 55 MCF - due to C6 blowing down while warming up Natural Gas Mcf 55 Maintenance 24 hours Farm 2/4/2024 2024 Flare Flared 25 MCF - nothing down Natural Gas Mcf 25 Maintenance 24 hours Rabbit Gulch 2/4/2024 2024 Flare Flared 1.6 MCF - unscheduled no flow throw 2 and 4.Natural Gas Mcf 1.6 Repair 24 hours Ravolla 2/4/2024 2024 Flare Flared 3 MCF - nothing down Natural Gas Mcf 3 Maintenance 24 hours Farm 2/5/2024 2024 Flare Flared 47.9 MCF - due to losing C6 on 1st stage high scrubber Natural Gas Mcf 47.9 Maintenance 24 hours Ravolla 2/5/2024 2024 Flare Flared 1.8 MCF - nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Farm 2/6/2024 2024 Flare Flared 1328 MCF - due to power bump causing all units to go down Natural Gas Mcf 1328 Emergency 24 hours Rabbit Gulch 2/6/2024 2024 Flare Flared 4.3 MCF - due to C2 scheduled down time Natural Gas Mcf 4.3 Maintenance 24 hours Ravolla 2/6/2024 2024 Flare Flared 296 MCF - due to high inlet pressure from Farm power dump Natural Gas Mcf 296 Emergency 24 hours Farm 2/7/2024 2024 Flare Flared 10.7 MCF - nothing down Natural Gas Mcf 10.7 Maintenance 24 hours Ravolla 2/7/2024 2024 Flare Flared 2.3 MCF - nothing down Natural Gas Mcf 2.3 Maintenance 24 hours Farm 2/8/2024 2024 Flare Flared 2.6 MCF - nothing down Natural Gas Mcf 2.6 Maintenance 24 hours Ravolla 2/8/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 2/9/2024 2024 Flare Flared 1.1 MCF - nothing down Natural Gas Mcf 1.1 Maintenance 24 hours Rabbit Gulch 2/9/2024 2024 Flare Flared 434 MCF - due to C3 down on electronic issues Natural Gas Mcf 434 Repair 24 hours Ravolla 2/9/2024 2024 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Farm 2/10/2024 2024 Flare Flared 3541.1 MCF - due to C4 & C5 was down for an hour and a half on 1st stage differential temp, due to coolers frozen and plugged from hydrates from units recycling gas from discharge back into 1st stage suction. Units started recycling due to decrease in gas volume from producers cutting back on production due to less oil take away for refineries down for turn around. Operational. DOGM 8547 Natural Gas Mcf 3541.1 Emergency 24 hours Rabbit Gulch 2/10/2024 2024 Flare Flared 360 MCF - due to C3 down on electronic issues and C1 down on control module fault Natural Gas Mcf 360 Repair 24 hours Ravolla 2/10/2024 2024 Flare Flared 309.2 MCF - due to farm being pressured up 309.2 Maintenance 24 hours Farm 2/11/2024 2024 Flare Flared 14.6 MCF - nothing down Natural Gas Mcf 14.6 Maintenance 24 hours Rabbit Gulch 2/11/2024 2024 Flare Flared 60 MCF - due to C3 and C1 down Natural Gas Mcf 60 Repair 24 hours Ravolla 2/11/2024 2024 Flare Flared 4.6 MCF - nothing down Natural Gas Mcf 4.6 Maintenance 24 hours Farm 2/12/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Rabbit Gulch 2/12/2024 2024 Flare Flared 96 MCF - due to C1 down on control module fault Natural Gas Mcf 96 Repair 24 hours Ravolla 2/12/2024 2024 Flare Flared 2.7 MCF - nothing down Natural Gas Mcf 2.7 Maintenance 24 hours Farm 2/13/2024 2024 Flare Flared 2 MCF - nothing down Natural Gas Mcf 2 Maintenance 24 hours Ravolla 2/13/2024 2024 Flare Flared 92.4 MCF - nothing down Natural Gas Mcf 29.4 Maintenance 24 hours Farm 2/14/2024 2024 Flare Flared 1432 MCF - due to losing C3 on low comp oil and C4 down for maintenance.Natural Gas Mcf 1432 Maintenance 24 hours Rabbit Gulch 2/14/2024 2024 Flare Flared 1.6 MCF - nothing down Natural Gas Mcf 1.6 Maintenance 24 hours Ravolla 2/14/2024 2024 Flare Flared 411 MCF - due to high field pressure due to Farm station high pressure Natural Gas Mcf 411 Maintenance 24 hours Farm 2/15/2024 2024 Flare Flared 17.8 MCF - nothing down Natural Gas Mcf 17.8 Maintenance 24 hours Ravolla 2/15/2024 2024 Flare Flared 3.6 MCF - nothing down Natural Gas Mcf 3.6 Maintenance 24 hours Farm 2/16/2024 2024 Flare Flared 1.74 MCF - nothing down Natural Gas Mcf 1.74 Maintenance 24 hours Ravolla 2/16/2024 2024 Flare Flared 2.3 MCF - nothing down Natural Gas Mcf 2.3 Maintenance 24 hours Farm 2/17/2024 2024 Flare Flared 1.36 MCF - nothing down Natural Gas Mcf 1.36 Maintenance 24 hours Rabbit Gulch 2/17/2024 2024 Flare Flared 140.8 MCF - C1 unscheduled down engine control module shut down.Natural Gas Mcf 140.8 Repair 24 hours Ravolla 2/17/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 2/18/2024 2024 Flare Flared 110 MCF - due to losing C3 on low comp oil pressure Natural Gas Mcf 110 Maintenance 24 hours Rabbit Gulch 2/18/2024 2024 Flare Flared 20.6 MCF - due to C4 unscheduled down engine control module shutdown.Natural Gas Mcf 20.6 Repair 24 hours Ravolla 2/18/2024 2024 Flare Flared 21 MCF - nothing down Natural Gas Mcf 21 Maintenance 24 hours Farm 2/19/2024 2024 Flare Flared 3.09 MCF - nothing down Natural Gas Mcf 3.09 Maintenance 24 hours Ravolla 2/19/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Farm 2/21/2024 2024 Flare Flare 26.5 MCF - nothing down Natural Gas Mcf 26.5 Maintenance 24 hours Ravolla 2/21/2024 2024 Flare Flared 2.7 MCF - nothing down Natural Gas Mcf 2.7 Maintenance 24 hours Farm 2/22/2024 2024 Flare Flared 3.1 MCF - nothing down Natural Gas Mcf 3.1 Maintenance 24 hours Ravolla 2/22/2024 2024 Flare Flared 530.3 MCF - due to C1 and C8 down Natural Gas Mcf 530.3 Repair 24 hours Farm 2/23/2024 2024 Flare Flared 2970 MCF - due to planned shutdown due to high pressure dump line damaged, operational. DOGM: 8463 Natural Gas Mcf 2970 Repair 24 hours Rabbit Gulch 2/23/2024 2024 Flare Flared 106 MCF - due to C1 and C2 down on low suction due to a line pig Natural Gas Mcf 106 Maintenance 24 hours Ravolla 2/23/2024 2024 Flare Flared 818.3 MCF - due to Farm station being down Natural Gas Mcf 818.3 Maintenance 24 hours Farm 2/24/2024 2024 Flare Flared 22571.3 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 22571.3 Repair 24 hours Ravolla 2/24/2024 2024 Flare Flared 3574.4 MCF - due to farm station being down. DOGM: 8464 Natural Gas Mcf 3574.4 Maintenance 24 hours Farm 2/25/2024 2024 Flare Flared 15879.3 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 15879.3 Repair 24 hours Ravolla 2/25/2024 2024 Flare Flared 2819.1 MCF - due to farm station being down. DOGM: 8464 Natural Gas Mcf 2819.1 Maintenance 24 hours Farm 2/26/2024 2024 Flare Flared 15908 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 15908 Repair 24 hours Ravolla 2/26/2024 2024 Flare Flared 2843 MCF - due to farm station being down. DOGM: 8464 Natural Gas Mcf 2843 Maintenance 24 hours Farm 2/27/2024 2024 Flare Flared 16540.1 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 16540.1 Repair 24 hours Ravolla 2/27/2024 2024 Flare Flared 1183 MCF - due to farm station being down.Natural Gas Mcf 1183 Maintenance 24 hours Farm 2/28/2024 2024 Flare Flared 13232 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 13232 Repair 24 hours Rabbit Gulch 2/28/2024 2024 Flare Flared 1.8 MCF - due to C1 down for engine control module Natural Gas Mcf 1.8 Repair 24 hours Ravolla 2/28/2024 2024 Flare Flared 1574 MCF - due to farm station being down. DOGM: 8472 Natural Gas Mcf 1574 Maintenance 24 hours Farm 2/29/2024 2024 Flare Flared 16008 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 16008 Repair 24 hours Rabbit Gulch 2/29/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Ravolla 2/29/2024 2024 Flare Flared 1320 MCF - due to farm station being down.Natural Gas Mcf 1320 Maintenance 24 hours Farm 3/1/2024 2024 Flare Flared 16064 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 16064 Repair 24 hours Ravolla 3/1/2024 2024 Flare Flared 2081 MCF - due to farm station being down. DOGM: 8473 Natural Gas Mcf 2081 Maintenance 24 hours Farm 3/2/2024 2024 Flare Flared 15823 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 15823 Repair 24 hours Ravolla 3/2/2024 2024 Flare Flared 2321 MCF - due to farm station being down. DOGM: 8473 Natural Gas Mcf 2321 Maintenance 24 hours Rabbit Gulch 3/3/2024 2024 Flare Flared 1.7 MCF - nothing down Natural Gas Mcf 1.7 Maintenance 24 hours Farm 3/4/2024 2024 Flare Flared 15772 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 15772 Repair 24 hours Rabbit Gulch 3/4/2024 2024 Flare Flared 65.5 MCF - nothing down Natural Gas Mcf 65.5 Maintenance 24 hours Ravolla 3/4/2024 2024 Flare Flared 877 MCF - due to farm station being down Natural Gas Mcf 877 Maintenance 24 hours Farm 3/5/2024 2024 Flare Flared 15050 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 15050 Repair 24 hours Ravolla 3/5/2024 2024 Flare Flared 449 MCF - due to farm station being down Natural Gas Mcf 449 Maintenance 24 hours Farm 3/6/2024 2024 Flare Flared 10657 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 10657 Repair 24 hours Rabbit Gulch 3/6/2024 2024 Flare Flared 691 MCF - due to scheduled water pump repairs Natural Gas Mcf 691 Maintenance 24 hours Ravolla 3/6/2024 2024 Flare Flared 524 MCF - due to farm station being down Natural Gas Mcf 524 Maintenance 24 hours Farm 3/7/2024 2024 Flare Flared 4226 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8463 Natural Gas Mcf 4226 Repair 24 hours Rabbit Gulch 3/7/2024 2024 Flare Flared 37 MCF - due to C3 down on aux water temp high Natural Gas Mcf 37 Repair 24 hours Ravolla 3/7/2024 2024 Flare Flared 216 MCF - due to farm station being down Natural Gas Mcf 216 Maintenance 24 hours Farm 3/8/2024 2024 Flare Flared 1493.7 MCF - due to planned shutdown due to high pressure dump line damaged. Natural Gas Mcf 1493.7 Repair 24 hours Rabbit Gulch 3/8/2024 2024 Flare Flared 159 MCF - due to C1 down on control module fault and C3 down on high water temp Natural Gas Mcf 159 Repair 24 hours Ravolla 3/8/2024 2024 Flare Flared 1.9 MCF - due to farm station being down Natural Gas Mcf 1.9 Maintenance 24 hours Farm 3/9/2024 2024 Flare Flared 1575.4 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8481 Natural Gas Mcf 1575.4 Repair 24 hours Rabbit Gulch 3/9/2024 2024 Flare Flared 467 MCF - due to control module fault Natural Gas Mcf 467 Repair 24 hours Ravolla 3/9/2024 2024 Flare Flared 1.8 MCF - nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Farm 3/10/2024 2024 Flare Flared 1511 MCF - due to planned shutdown due to high pressure dump line damaged. DOGM: 8481 Natural Gas Mcf 1511 Repair 24 hours Rabbit Gulch 3/10/2024 2024 Flare Flared 5 MCF - due to C1 down on control module fault Natural Gas Mcf 5 Repair 24 hours Ravolla 3/10/2024 2024 Flare Flared 2.8 MCF - nothing down Natural Gas Mcf 2.8 Maintenance 24 hours Rabbit Gulch 3/11/2024 2024 Flare Flared 1329 MCF - due to C1 down for scheduled top end overhaul Natural Gas Mcf 1329 Maintenance 24 hours Farm 3/12/2024 2024 Flare Flared 8.3 MCF - nothing down Natural Gas Mcf 8.3 Maintenance 24 hours Rabbit Gulch 3/12/2024 2024 Flare Flared 1358.2 MCF - due to C1 scheduled down time for top end Natural Gas Mcf 1358.2 Maintenance 24 hours Ravolla 3/12/2024 2024 Flare Flared 20.7 MCF - nothing down Natural Gas Mcf 20.7 Maintenance 24 hours Farm 3/13/2024 2024 Flare Flared 264 MCF - due to multiple units going down on high load when receiving a pig.Natural Gas Mcf 264 Emergency 24 hours Rabbit Gulch 3/13/2024 2024 Flare Flared 118.6 MCF - due to C1 scheduled down time for top end Natural Gas Mcf 118.6 Maintenance 24 hours Ravolla 3/13/2024 2024 Flare Flared 6.9 MCF - nothing down Natural Gas Mcf 6.9 Maintenance 24 hours Farm 3/14/2024 2024 Flare Flared 389 MCF - due to losing multiple units on high load while receiving a pig Natural Gas Mcf 389 Emergency 24 hours Rabbit Gulch 3/14/2024 2024 Flare Flared 143.8 MCF - due to C1 scheduled down time for top end Natural Gas Mcf 143.8 Maintenance 24 hours Ravolla 3/14/2024 2024 Flare Flared 579 MCF - due to high field pressure with Farm units going down and high field pressure with shutting C1 due to over sending to the plant Natural Gas Mcf 579 Emergency 24 hours Farm 3/15/2024 2024 Flare Flared 133 MCF - due to losing units from over load due to a pig Natural Gas Mcf 133 Emergency 24 hours Ravolla 3/15/2024 2024 Flare Flared 913 MCF - due to C1 being down. It had to be left down for 8 hours due to plant capacity and couldn't take any more gas.Natural Gas Mcf 913 Maintenance 24 hours Farm 3/16/2024 2024 Flare Flared 166 MCF - due to losing multiple units on high while receiving a pig Natural Gas Mcf 166 Emergency 24 hours Ravolla 3/16/2024 2024 Flare Flared 157 MCF - due to high field pressure with farm units going down Natural Gas Mcf 157 Emergency 24 hours Rabbit Gulch 3/17/2024 2024 Flare Flared 91.9 MCF - due to C-1 and 2 unscheduled low suction pressure.Natural Gas Mcf 91.9 Repair 24 hours Farm 3/18/2024 2024 Flare Flared 9 MCF - nothing down Natural Gas Mcf 9 Maintenance 24 hours Rabbit Gulch 3/18/2024 2024 Flare Flared 160.6 MCF - nothing down, producer adjusting line pressure Natural Gas Mcf 160.6 Maintenance 24 hours Ravolla 3/18/2024 2024 Flare Flared 8.1 MCF - nothing down Natural Gas Mcf 8.1 Maintenance 24 hours Farm 3/19/2024 2024 Flare Flared 10 MCF - nothing down Natural Gas Mcf 10 Maintenance 24 hours Rabbit Gulch 3/19/2024 2024 Flare Flared 164 MCF - due to C1 down on scheduled top end valve adjustment and inspection and C2 flare valve was cracked open, didn't shut all the way.Natural Gas Mcf 164 Maintenance 24 hours Ravolla 3/19/2024 2024 Flare Flared 3.2 MCF - nothing down Natural Gas Mcf 3.2 Maintenance 24 hours Farm 3/20/2024 2024 Flare Flared 704.2 MCF - due to planned station shut down to tie in the new NGL tank Natural Gas Mcf 704.2 Maintenance 24 hours Rabbit Gulch 3/20/2024 2024 Flare Flared 59 MCF - due to farm statin shut in for a tie in, caused stations to build high pressure.Natural Gas Mcf 59 Emergency 24 hours Ravolla 3/20/2024 2024 Flare Flared 1741 MCF - due to station pressured up from planned shut down of Farm for NGL tank tie in. DOGM: 8489 Natural Gas Mcf 1741 Emergency 24 hours Farm 3/21/2024 2024 Flare Flared 19 MCF - nothing down Natural Gas Mcf 19 Maintenance 24 hours Rabbit Gulch 3/21/2024 2024 Flare Flared 1 MCF - due to C3 shutdown to check and adjust fluid levels Natural Gas Mcf 1 Maintenance 24 hours Ravolla 3/21/2024 2024 Flare Flared 43 MCF - nothing down Natural Gas Mcf 43 Maintenance 24 hours Farm 3/22/2024 2024 Flare Flared 239.8 MCF - due to C2 down on high compressor vibration Natural Gas Mcf 239.8 Repair 24 hours Ravolla 3/22/2024 2024 Flare Flared 145.7 MCF - due to C3 down with a coolant leak Natural Gas Mcf 145.7 Repair 24 hours Farm 3/23/2024 2024 Flare Flared 16.1 MCF - due to C4 was down on low engine speed Natural Gas Mcf 16.1 Repair 24 hours Ravolla 3/23/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 3/24/2024 2024 Flare Flared 635.5 MCF - due to PSD for low fuel gas pressure Natural Gas Mcf 635.5 Emergency 24 hours Ravolla 3/24/2024 2024 Flare Flared 896.6 MCF - due to station pressured up because Farm went down Natural Gas Mcf 896.6 Emergency 24 hours Farm 3/26/2024 2024 Flare Flared 14.8 MCF - nothing down Natural Gas Mcf 14.8 Maintenance 24 hours Ravolla 3/26/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 3/27/2024 2024 Flare Flared 20 MCF - nothing down Natural Gas Mcf 20 Maintenance 24 hours Rabbit Gulch 3/27/2024 2024 Flare Flared 2516 - due to planned pipeline maintenance, dropped flare set point to 30 for line tie in. DOGM: 8494 Natural Gas Mcf 2516 Maintenance 24 hours Ravolla 3/27/2024 2024 Flare Flared 50 MCF - due to C2 down with blown fuse inside PLC.Natural Gas Mcf 50 Repair 24 hours Farm 3/28/2024 2024 Flare Flared 50 MCF - due to C1 shut down for maintenance Natural Gas Mcf 50 Maintenance 24 hours Rabbit Gulch 3/28/2024 2024 Flare Flared 2731 MCF - due to planned pipeline maintenance, dropped flare set point to 30 for line tie in. DOGM: 8494 Natural Gas Mcf 2731 Maintenance 24 hours Ravolla 3/28/2024 2024 Flare Flared 18 MCF - nothing down Natural Gas Mcf 18 Maintenance 24 hours Rabbit Gulch 3/29/2024 2024 Flare Flared 1220 MCF - due to high field pressure due to pipeline maintenance.Natural Gas Mcf 1220 Maintenance 24 hours Farm 3/30/2024 2024 Flare Flared 9 MCF - nothing down Natural Gas Mcf 9 Maintenance 24 hours Rabbit Gulch 3/30/2024 2024 Flare Flared 9200 MCF - due to units C-1, 2, and 3 down on high 3rd stage discharge pressure from ongoing pipeline maintenance. DOGM 8495 Natural Gas Mcf 9200 Maintenance 24 hours Ravolla 3/30/2024 2024 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Farm 3/31/2024 2024 Flare Flared 1004 MCF - due to C5 going down on main bearing temp Natural Gas Mcf 1004 Repair 24 hours Rabbit Gulch 3/31/2024 2024 Flare Flared 445 MCF - due to unscheduled C-3 downtime on low compressor oil.Natural Gas Mcf 445 Repair 24 hours Ravolla 3/31/2024 2024 Flare Flared 1412 MCF - due to high field pressure with C5 being down at Farm Natural Gas Mcf 1412 Maintenance 24 hours Farm 4/1/2024 2024 Flare Flared 1004 MCF - due to high field pressure with C3 being down at Ravolla Natural Gas Mcf 1004 Maintenance 24 hours Rabbit Gulch 4/1/2024 2024 Flare Flared 212 MCF - due to C3 down for unscheduled compressor valve replacement Natural Gas Mcf 212 Repair 24 hours Ravolla 4/1/2024 2024 Flare Flared 1412 MCF - due to high field pressure with C3 being down with mechanical issues.Natural Gas Mcf 1412 Maintenance 24 hours Farm 4/2/2024 2024 Flare Flared 4406 MCF - due to planned outage so Mountain West could send smart pig on discharge line. DOGM 8501 Natural Gas Mcf 4406 Maintenance 24 hours Ravolla 4/2/2024 2024 Flare Flared 5786 MCF - due to planned outage so Mountain West could send smart pig on discharge line. DOGM 8502 Natural Gas Mcf 5786 Maintenance 24 hours Farm 4/3/2024 2024 Flare Flared 777.2 MCF - due to C6 down with broken belts Natural Gas Mcf 777.2 Repair 24 hours Rabbit Gulch 4/3/2024 2024 Flare Flared 1 MCF - due to unit down at West Station cause pressures to build.Natural Gas Mcf 1 Maintenance 24 hours Ravolla 4/3/2024 2024 Flare Flared 242 MCF - due to C3 down for mechanical work Natural Gas Mcf 242 Maintenance 24 hours Farm 4/4/2024 2024 Flare Flared 450.8 MCF - due to C6 down on low compressor oil Natural Gas Mcf 450.8 Repair 24 hours Ravolla 4/4/2024 2024 Flare Flared 921 MCF - due to high station pressure Natural Gas Mcf 921 Maintenance 24 hours Farm 4/7/2024 2024 Flare Flared 9.3 MCF - nothing down Natural Gas Mcf 9.3 Maintenance 24 hours Rabbit Gulch 4/7/2024 2024 Flare Flared 58 MCF - due to Javelin opened up the Homelite Well and put it online causing high station pressure Natural Gas Mcf 58 Maintenance 24 hours Ravolla 4/7/2024 2024 Flare Flared 0.8 MCF - nothing down Natural Gas Mcf 0.8 Maintenance 24 hours Farm 4/8/2024 2024 Flare Flared 15.7 MCF - nothing down Natural Gas Mcf 15.7 Maintenance 24 hours Rabbit Gulch 4/8/2024 2024 Flare Flared 172 MCF - due to Javelin opened up the Homelite well and brought on high station pressures Natural Gas Mcf 172 Maintenance 24 hours Ravolla 4/8/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 4/9/2024 2024 Flare Flared 1020.5 MCF - due to C4 down on low engine speed Natural Gas Mcf 1020.5 Maintenance 24 hours Rabbit Gulch 4/9/2024 2024 Flare Flared 4357 MCF - due to scheduled 8K maintenance on Unit C-1. DOGM 8504.Natural Gas Mcf 4357 Maintenance 24 hours Ravolla 4/9/2024 2024 Flare Flared 165 MCF - due to Farm being presesured up Natural Gas Mcf 165 Maintenance 24 hours Farm 4/10/2024 2024 Flare Flared 1372 MCF - due to C4 going down on under speed and C6 going down on high 3rd stage discharge Natural Gas Mcf 1372 Repair 24 hours Rabbit Gulch 4/10/2024 2024 Flare Flared 6841 MCF - due to C1 down for scheduled maintenance. DOGM 8506.Natural Gas Mcf 6841 Maintenance 24 hours Ravolla 4/10/2024 2024 Flare Flared 68 MCF - due to high field pressure with Farm units being down Natural Gas Mcf 68 Repair 24 hours Farm 4/11/2024 2024 Flare Flared 1695 MCF - due to C4 being down for multiple hours for repairs for mechanical issues. DOGM 8507 Natural Gas Mcf 1695 Repair 24 hours Rabbit Gulch 4/11/2024 2024 Flare Flared 3407 MCF - due to C1 down for scheduled 8k maintenance. DOGM 8509 Natural Gas Mcf 3407 Maintenance 24 hours Ravolla 4/11/2024 2024 Flare Flared 691 MCF - due to high field pressure with C4 down at Farm and C2 down at Ravolla for planned maintenance Natural Gas Mcf 691 Maintenance 24 hours Farm 4/12/2024 2024 Flare Flared 928 MCF - due to C6 going down on high discharge pressure Natural Gas Mcf 928 Maintenance 24 hours Rabbit Gulch 4/12/2024 2024 Flare Flared 15 MCF - nothing down Natural Gas Mcf 15 Maintenance 24 hours Ravolla 4/12/2024 2024 Flare Flared 46 MCF - due to high field pressure with C6 down at Farm Natural Gas Mcf 46 Maintenance 24 hours Farm 4/13/2024 2024 Flare Flared 12.2 MCF - nothing down Natural Gas Mcf 12.2 Maintenance 24 hours Rabbit Gulch 4/13/2024 2024 Flare Flared 20 MCF - nothing down Natural Gas Mcf 20 Maintenance 24 hours Ravolla 4/13/2024 2024 Flare Flared 1.1 MCF - nothing down Natural Gas Mcf 1.1 Maintenance 24 hours Farm 4/14/2024 2024 Flare Flared 576 MCF - due to high field pressure Natural Gas Mcf 576 Maintenance 24 hours Ravolla 4/14/2024 2024 Flare Flared 34.5 MCF - due to losing C6 on engine control module shutdown Natural Gas Mcf 34.5 Repair 24 hours Farm 4/15/2024 2024 Flare Flared 718 MCF - due to high field pressure from PM on Ravolla C3 Natural Gas Mcf 718 Maintenance 24 hours Ravolla 4/15/2024 2024 Flare Flared 19 MCF - due to C3 down for PM Natural Gas Mcf 19 Maintenance 24 hours Farm 4/16/2024 2024 Flare Flared 1994 MCF - due to planned shutdown of C4, C5 & C6 for MWP smart pig. DOGM 8515 Natural Gas Mcf 1994 Maintenance 24 hours Rabbit Gulch 4/16/2024 2024 Flare Flared 610 MCF - due to units down at South station causing high station pressure Natural Gas Mcf 610 Maintenance 24 hours Ravolla 4/16/2024 2024 Flare Flared 2020 MCF - due to high field pressure with Farm units being down during planned MWP smart pigging. DOGM 8516 Natural Gas Mcf 2020 Maintenance 24 hours Farm 4/17/2024 2024 Flare Flared 901 MCF - due to C6 down on low engine speed and C3 down with a coolant leak Natural Gas Mcf 901 Repair 24 hours Rabbit Gulch 4/17/2024 2024 Flare Flared 48 MCF - due to C2 went down on 3rd stage high discharge Natural Gas Mcf 48 Repair 24 hours Ravolla 4/17/2024 2024 Flare Flared 4.8 MCF - nothing down Natural Gas Mcf 4.8 Maintenance 24 hours Farm 4/18/2024 2024 Flare Flared 3042.6 MCF - due to four engines down all day for planned MWP smart pig run, operational. DOGM 8523 Natural Gas Mcf 3042.6 Maintenance 24 hours Rabbit Gulch 4/18/2024 2024 Flare Flared 519 MCF - due to C2 & C3 went down on 3rd stage high dischrge Natural Gas Mcf 519 Maintenance 24 hours Ravolla 4/18/2024 2024 Flare Flared 2236 MCF - due to station pressured up due to Farm units being down for planned MWP smart pig run, operational. DOGM 8522 Natural Gas Mcf 2236 Maintenance 24 hours Farm 4/19/2024 2024 Flare Flared 2521.1 MCF - due to planned MWP pipeline maintenance Shutting units down so MWP could run a smart pig, operational. DOGM 8523 Natural Gas Mcf 2521.1 Maintenance 24 hours Rabbit Gulch 4/19/2024 2024 Flare Flared 2 MCF - due to MWP smart pigging Natural Gas Mcf 2 Maintenance 24 hours Ravolla 4/19/2024 2024 Flare Flared 1796 MCF - due to planned MWP pipeline maintenance Shutting units down so MWP could run a smart pig, operational. DOGM 8522 Natural Gas Mcf 1796 Maintenance 24 hours Farm 4/20/2024 2024 Flare Flared 1796 MCF - due to planned MWP pipeline maintenance, station due to no volume allowed while maintenance work is in progress, operational. DOGM 8523 Natural Gas Mcf 1796 Maintenance 24 hours Ravolla 4/20/2024 2024 Flare Flared 8999.7 MCF - due to planned MWP pipeline maintenance, station pressured up due to Farm being down, operational. DOGM 8522 Natural Gas Mcf 8999.7 Maintenance 24 hours Farm 4/21/2024 2024 Flare Flared 10518 MCF - due to planned MWP pipeline maintenance, station due to no volume allowed while maintenance work is in progress, operational. DOGM 8523 Natural Gas Mcf 10518 Maintenance 24 hours Ravolla 4/21/2024 2024 Flare Flared 13269 MCF - due to planned MWP pipeline maintenance, station pressured up due to Farm being down, operational. DOGM 8522 Natural Gas Mcf 13269 Maintenance 24 hours Farm 4/22/2024 2024 Flare Flared 10290 MCF - due to planned MWP pipeline maintenance, station due to no volume allowed while maintenance work is in progress, operational. DOGM 8523 Natural Gas Mcf 10290 Maintenance 24 hours Ravolla 4/22/2024 2024 Flare Flared 12623 MCF - due to planned MWP pipeline maintenance, station pressured up due to Farm being down, operational. DOGM 8522 Natural Gas Mcf 12623 Maintenance 24 hours Farm 4/23/2024 2024 Flare Flared 10121 MCF - due to planned MWP pipeline maintenance, station due to no volume allowed while maintenance work is in progress, operational. DOGM 8523 Natural Gas Mcf 10121 Maintenance 24 hours Rabbit Gulch 4/23/2024 2024 Flare Flared 383 MCF - due C2 scheduled down 2K maintenance and unscheduled down on high discharge 3rd stage Natural Gas Mcf 383 Maintenance 24 hours Ravolla 4/23/2024 2024 Flare Flared 12118 MCF - due to planned MWP pipeline maintenance, station pressured up due to Farm being down, operational. DOGM 8522 Natural Gas Mcf 12118 Maintenance 24 hours Farm 4/24/2024 2024 Flare Flared 8404 MCF - due to planned MWP pipeline maintenance, station due to no volume allowed while maintenance work is in progress, operational. DOGM 8523 Natural Gas Mcf 8404 Maintenance 24 hours Rabbit Gulch 4/24/2024 2024 Flare Flared 418 MCF - due to C1 & C2 unscheduled down on high discharge Natural Gas Mcf 418 Repair 24 hours Ravolla 4/24/2024 2024 Flare Flared 7518 MCF - due to planned MWP pipeline maintenance, station pressured up due to Farm being down, operational. DOGM 8522 Natural Gas Mcf 7518 Maintenance 24 hours Farm 4/25/2024 2024 Flare Flared 539 MCF- due to high field perssure with C6 idling back on high discharge pressure and also losing C6 on high load.Natural Gas Mcf 539 Repair 24 hours Ravolla 4/25/2024 2024 Flare Flared 6.8 MCF - nothing down Natural Gas Mcf 6.8 Maintenance 24 hours Farm 4/26/2024 2024 Flare Flared 136 MCF - due to C6 going down on high discharge pressure Natural Gas Mcf 136 Repair 24 hours Rabbit Gulch 4/26/2024 2024 Flare Flared 35 MCF - nothing down Natural Gas Mcf 35 Repair 24 hours Ravolla 4/26/2024 2024 Flare Flared 47.9 MCF - due to high field pressure with C6 being down at Farm Natural Gas Mcf 47.9 Maintenance 24 hours Farm 4/27/2024 2024 Flare Flared 15.7 MCF - nothing down Natural Gas Mcf 15.7 Maintenance 24 hours Rabbit Gulch 4/27/2024 2024 Flare Flared 325 MCF - nothing down Natural Gas Mcf 325 Maintenance 24 hours Ravolla 4/27/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 4/28/2024 2024 Flare Flared 14 MCF - nothing down Natural Gas Mcf 14 Maintenance 24 hours Rabbit Gulch 4/28/2024 2024 Flare Flared 763 MCF - due to field pressured up due to maintenance at West C3 Natural Gas Mcf 763 Maintenance 24 hours Ravolla 4/28/2024 2024 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Farm 4/29/2024 2024 Flare Flared 18 MCF - nothing down Natural Gas Mcf 18 Maintenance 24 hours Rabbit Gulch 4/29/2024 2024 Flare Flared 188 MCF - nothing down Natural Gas Mcf 188 Maintenance 24 hours Ravolla 4/29/2024 2024 Flare Flared 6.7 MCF - nothing down Natural Gas Mcf 6.7 Maintenance 24 hours Farm 4/30/2024 2024 Flare Flared 420 MCF - due to C5 going down on high second stage scrubber level Natural Gas Mcf 420 Repair 24 hours Rabbit Gulch 4/30/2024 2024 Flare Flared 3.9 MCF - due to high station pressure from C4 being down Natural Gas Mcf 3.9 Maintenance 24 hours Ravolla 4/30/2024 2024 Flare Flared 2.9 MCF - nothing down Natural Gas Mcf 2.9 Maintenance 24 hours Farm 5/1/2024 2024 Flare Flared 178.7 MCF - due to C6 & C5 down for repairds Natural Gas Mcf 178.7 Repair 24 hours Rabbit Gulch 5/1/2024 2024 Flare Flared 614 MCF - due to C3 down for scheduled maintenance Natural Gas Mcf 614 Maintenance 24 hours Ravolla 5/1/2024 2024 Flare Flared 2.7 MCF - nothing down Natural Gas Mcf 2.7 Maintenance 24 hours Farm 5/2/2024 2024 Flare Flared 96.2 MCF - due to C5 down waiting to get a new pre- lube pump installed Natural Gas Mcf 96.2 Repair 24 hours Rabbit Gulch 5/2/2024 2024 Flare Flared 101 MCF - due to C2 down for oil level adjustment and repair Natural Gas Mcf 101 Repair 24 hours Ravolla 5/2/2024 2024 Flare Flared 18.5 MCF - nothing down Natural Gas Mcf 18.5 Maintenance 24 hours Farm 5/3/2024 2024 Flare Flared 310 MCF - due to C2 down on 3rd stage scrubble high level Natural Gas Mcf 310 Repair 24 hours Rabbit Gulch 5/3/2024 2024 Flare Flared 59 MCF - due to 2 units down at Farm causing high station pressure Natural Gas Mcf 59 Maintenance 24 hours Ravolla 5/3/2024 2024 Flare Flared 2.1 MCF - nothing down Natural Gas Mcf 2.1 Maintenance 24 hours Farm 5/4/2024 2024 Flare Flared 1528.1 MCF - due to C2 & C6 down on 3rd stage scrubber high level, operational. DOGM 8538 Natural Gas Mcf 1528.1 Repair 24 hours Ravolla 5/4/2024 2024 Flare Flared 26.8 MCF - nothing down Natural Gas Mcf 26.8 Maintenance 24 hours Farm 5/5/2024 2024 Flare Flared 16 MCF - nothing down Natural Gas Mcf 16 Maintenance 24 hours Rabbit Gulch 5/5/2024 2024 Flare Flared 70 MCF - due to high line pressure on the East side and causing high station pressure Natural Gas Mcf 70 Maintenance 24 hours Ravolla 5/5/2024 2024 Flare Flared 68 MCF - nothing down Natural Gas Mcf 68 Maintenance 24 hours Farm 5/6/2024 2024 Flare Flared 16.6 MCF - nothing down Natural Gas Mcf 16.6 Maintenance 24 hours Rabbit Gulch 5/6/2024 2024 Flare Flared 3563 MCF - due to C3 down for a scheduled 8K service and causing high station pressures. DOGM 8541 Natural Gas Mcf 3563 Maintenance 24 hours Ravolla 5/6/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 5/7/2024 2024 Flare Flared 477.1 MCF - due to Mountain West had fluid in their line that backed up the pipeline Natural Gas Mcf 477.1 Maintenance 24 hours Rabbit Gulch 5/7/2024 2024 Flare Flared 4419 MCF - due to C3 down for a scheduled 8K service and causing high station pressures. DOGM 8541 Natural Gas Mcf 4419 Maintenance 24 hours Ravolla 5/7/2024 2024 Flare Flared 70.3 MCF - due to Farm being pressured up Natural Gas Mcf 70.3 Maintenance 24 hours Farm 5/8/2024 2024 Flare Flared 16.5 MCF - nothing down Natural Gas Mcf 16.5 Maintenance 24 hours Rabbit Gulch 5/8/2024 2024 Flare Flared 3514 MCF - due to C3 down for a scheduled 8K service and causing high station pressures. DOGM 8541 Natural Gas Mcf 3514 Maintenance 24 hours Ravolla 5/8/2024 2024 Flare Flared 24 MCF - due to C6 down on high right bank discharge Natural Gas Mcf 24 Repair 24 hours Farm 5/9/2024 2024 Flare Flared 20.4 MCF - nothing down Natural Gas Mcf 20.4 Maintenance 24 hours Rabbit Gulch 5/9/2024 2024 Flare Flared 1286 MCF - due to C3 down for a scheduled 8K service and causing high station pressures. Natural Gas Mcf 1286 Maintenance 24 hours Ravolla 5/9/2024 2024 Flare Flared 59.1 MCF - due to C1 down for planned maintenance Natural Gas Mcf 59.1 Maintenance 24 hours Farm 5/10/2024 2024 Flare Flared 12.51 MCF - nothing down Natural Gas Mcf 12.51 Maintenance 24 hours Ravolla 5/10/2024 2024 Flare Flared 1 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Farm 5/11/2024 2024 Flare Flared 505 MCF - due to C6 going down multiple times on high 3rd stage pressure Natural Gas Mcf 505 Repair 24 hours Ravolla 5/11/2024 2024 Flare Flared 7.6 MCF - nothing down Natural Gas Mcf 7.6 Maintenance 24 hours Farm 5/12/2024 2024 Flare Flared 256 MCF - due to losing C4 twice on high 3rd stage compressor temp Natural Gas Mcf 256 Repair 24 hours Ravolla 5/12/2024 2024 Flare Flared 112 MCF - due to losing C8 on high oil temp Natural Gas Mcf 112 Repair 24 hours Farm 5/13/2024 2024 Flare Flared 660 MCF - due to multiple units going down with low suction pressure due to Farm inlet piping receiving a pigging liquids is an unpiggable section of piping Natural Gas Mcf 660 Maintenance 24 hours Rabbit Gulch 5/13/2024 2024 Flare Flared 77 MCF - nothing down Natural Gas Mcf 77 Maintenance 24 hours Ravolla 5/13/2024 2024 Flare Flared 189 MCF - due to high field pressure with Farm units being down Natural Gas Mcf 189 Maintenance 24 hours Farm 5/14/2024 2024 Flare Flared 662 MCF - due to shutting down C6 for Dominion smart pig and C1 for 2K service.Natural Gas Mcf 662 Maintenance 24 hours Ravolla 5/14/2024 2024 Flare Flared 1193 MCF - due to high field pressure with Farm units being down and shutting C3 down to replace leaking turbo manifold.Natural Gas Mcf 1193 Maintenance 24 hours Rabbit Gulch 5/15/2024 2024 Flare Flared 985 MCF - nothing down Natural Gas Mcf 985 Maintenance 24 hours Farm 5/16/2024 2024 Flare Flared 23.2 MCF - due to C5 down for a couple of hours on low engine speed Natural Gas Mcf 23.2 Repair 24 hours Rabbit Gulch 5/16/2024 2024 Flare Flared 999 MCF - due to C3 down twice for unscheduled flow Natural Gas Mcf 999 Repair 24 hours Ravolla 5/16/2024 2024 Flare Flared 2.2 MCF - due to Farm being pressured up Natural Gas Mcf 2.2 Maintenance 24 hours Farm 5/17/2024 2024 Flare Flared 473 MCF - due to C5 & C6 down for unplanned low engine speed Natural Gas Mcf 473 Repair 24 hours Rabbit Gulch 5/17/2024 2024 Flare Flared 101 MCF - nothing down Natural Gas Mcf 101 Maintenance 24 hours Ravolla 5/17/2024 2024 Flare Flared 256 MCF - due to C3 down for planned coolant leak repair Natural Gas Mcf 256 Repair 24 hours Farm 5/18/2024 2024 Flare Flared 14.4 MCF - nothing down Natural Gas Mcf 14.4 Maintenance 24 hours Ravolla 5/18/2024 2024 Flare Flared 3.1 MCF - nothing down Natural Gas Mcf 3.1 Maintenance 24 hours Farm 5/19/2024 2024 Flare Flared 14.3 MCF - nothing down Natural Gas Mcf 14.3 Maintenance 24 hours Rabbit Gulch 5/19/2024 2024 Flare Flared 42 MCF - nothing down Natural Gas Mcf 42 Maintenance 24 hours Ravolla 5/19/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 5/20/2024 2024 Flare Flared 779.4 MCF - due to C5 down 14 hours on low engine speed from misfire Natural Gas Mcf 779.4 Maintenance 24 hours Rabbit Gulch 5/20/2024 2024 Flare Flared 150 MCF - due to C2 down on low compressor oil level, unplanned.Natural Gas Mcf 150 Repair 24 hours Ravolla 5/20/2024 2024 Flare Flared 352 MCF - due to C1 down for 2 hours on low compressor oil level Natural Gas Mcf 352 Maintenance 24 hours Farm 5/21/2024 2024 Flare Flared 623.2 MCF - due to C5 down for 3 hours on low engine speed from a misfire Natural Gas Mcf 623.2 Maintenance 24 hours Rabbit Gulch 5/21/2024 2024 Flare Flared 1.8 MCF - nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Ravolla 5/21/2024 2024 Flare Flared 12.3 MCF - nothing down Natural Gas Mcf 12.3 Maintenance 24 hours Farm 5/22/2024 2024 Flare Flared 124 MCF - due to C6 and C5 going down on 2nd stage level high Natural Gas Mcf 124 Repair 24 hours Ravolla 5/22/2024 2024 Flare Flared 16.7 MCF - nothing down Natural Gas Mcf 16.7 Maintenance 24 hours Farm 5/23/2024 2024 Flare Flared 334 MCF - due to C6 going down on high scrubber level Natural Gas Mcf 334 Repair 24 hours Ravolla 5/23/2024 2024 Flare Flared 210 MCF - due to shutting C1 & C7 down to relieve gas for smart pig.Natural Gas Mcf 210 Maintenance 24 hours Farm 5/24/2024 2024 Flare Flared 14.25 MCF - nothing down Natural Gas Mcf 14.25 Maintenance 24 hours Rabbit Gulch 5/24/2024 2024 Flare Flared 88 MCF - due to C4 unscheduled compressor oil pressure low shut down Natural Gas Mcf 88 Repair 24 hours Ravolla 5/24/2024 2024 Flare Flared 1.8 MCF - nothing down Natural Gas Mcf 1.8 Maintenance 24 hours Farm 5/25/2024 2024 Flare Flared 719 MCF - due to losing all units twice from power bump Natural Gas Mcf 719 Maintenance 24 hours Rabbit Gulch 5/25/2024 2024 Flare Flared 587 MCF - due to C3 unscheduled compressor oil pressure low shutdown (bad pressure transmitter, replaced it)Natural Gas Mcf 587 Repair 24 hours Ravolla 5/25/2024 2024 Flare Flared 452 MCF - due to high field pressure with Farm station going down twice Natural Gas Mcf 452 Maintenance 24 hours Farm 5/26/2024 2024 Flare Flared 234 MCF - due to losing C5 multiple times on high temp due to ambient temp Natural Gas Mcf 234 Maintenance 24 hours Ravolla 5/26/2024 2024 Flare Flared 0.9 MCF - nothing down Natural Gas Mcf 0.9 Maintenance 24 hours Farm 5/27/2024 2024 Flare Flared 9.7 MCF - nothing down Natural Gas Mcf 10 Maintenance 24 hours Rabbit Gulch 5/27/2024 2024 Flare Flared 339 MCF - due to C2 down multiple times, unscheduled, from cylinder 4 high temp (replaced all three valves on 2nd stage dischrge)Natural Gas Mcf 339 Repair 24 hours Ravolla 5/27/2024 2024 Flare Flared 0.8 MCF - nothing down Natural Gas Mcf 1 Maintenance 24 hours Farm 5/28/2024 2024 Flare Flared 5310 MCF - due to planned shut down for Dominion pigging. DOGM 8563 Natural Gas Mcf 5310 Maintenance 24 hours Ravolla 5/28/2024 2024 Flare Flared 7264 MCF - due to high field pressure with Farm station being down. DOGM 8564 Natural Gas Mcf 7264 Maintenance 24 hours Farm 5/30/2024 2024 Flare Flared 10227.2 MCF - due to station shutdown for Mountain West Pipeline maintenance. DOGM 8567 Natural Gas Mcf 10227.2 Maintenance 24 hours Rabbit Gulch 5/30/2024 2024 Flare Flared 269 MCF - due to scheduled maintenance on C2 and C1 went down on Control Module fault Natural Gas Mcf 269 Maintenance 24 hours Ravolla 5/30/2024 2024 Flare Flared 10832.5 MCF - due to station pressured up due to Farm MWP maintenance work. DOGM 8566 Natural Gas Mcf 10832.5 Maintenance 24 hours Farm 5/31/2024 2024 Flare Flared 5640 MCF - due to station shutdown for Mountain West Pipeline maintenance. DOGM 8567 Natural Gas Mcf 5640 Maintenance 24 hours Ravolla 5/31/2024 2024 Flare Flared 3680.4 MCF - due to station pressured up due to Farm MWP maintenance work. DOGM 8566 Natural Gas Mcf 3680.4 Maintenance 24 hours Farm 6/1/2024 2024 Flare Flared 2299 MCF - due to station shutdown for Mountain West Pipeline maintenance. DOGM 8567 Natural Gas Mcf 2299 Maintenance 24 hours Rabbit Gulch 6/1/2024 2024 Flare Flared 391 MCF - due to high pressure from a unit down at South Station Natural Gas Mcf 391 Maintenance 24 hours Ravolla 6/1/2024 2024 Flare Flared 1530 MCF - due to station pressured up due to Farm MWP maintenance work. DOGM 8566 Natural Gas Mcf 1530 Maintenance 24 hours Farm 6/2/2024 2024 Flare Flared 1701.9 MCF - due to Plant and stations shutdowns. DOGM 8571 Natural Gas Mcf 1701.9 Maintenance 24 hours Rabbit Gulch 6/2/2024 2024 Flare Flared 19218 MCF - due to Plant and stations shutdowns. DOGM 8574 Natural Gas Mcf 19218 Maintenance 24 hours Ravolla 6/2/2024 2024 Flare Flared 6644.4 MCF - due to Plant and stations shutdowns. DOGM 8570 Natural Gas Mcf 6644.4 Maintenance 24 hours Farm 6/3/2024 2024 Flare Flared 19.8 MCF - nothing down Natural Gas Mcf 19.8 Maintenance 24 hours Rabbit Gulch 6/3/2024 2024 Flare Flared 17952 MCF - due to Plant and stations shutdowns. DOGM 8574 Natural Gas Mcf 17952 Maintenance 24 hours Ravolla 6/3/2024 2024 Flare Flared 15046.7 MCF - due to Plant and stations shutdowns. DOGM 8570 Natural Gas Mcf 15046.7 Maintenance 24 hours Rabbit Gulch 6/4/2024 2024 Flare Flared 18358 MCF - due to Plant and stations shutdowns. DOGM 8574 Natural Gas Mcf 18358 Maintenance 24 hours Ravolla 6/4/2024 2024 Flare Flared 16921.2 MCF - due to Plant and stations shutdowns. DOGM 8570 Natural Gas Mcf 16921.2 Maintenance 24 hours Farm 6/4/2024 2024 Flare Flared 163 MCF - due to C5 down on low engine speed Natural Gas Mcf 163 Repair 24 hours Farm 6/5/2024 2024 Flare Flared 452 MCF - due to C5 down on low suction Natural Gas Mcf 452 Maintenance 24 hours Rabbit Gulch 6/5/2024 2024 Flare Flared 18948 MCF - due to Plant and stations shutdowns. DOGM 8574 Natural Gas Mcf 18948 Maintenance 24 hours Ravolla 6/5/2024 2024 Flare Flared 17643 MCF - due to Plant and stations shutdowns. DOGM 8570 Natural Gas Mcf 17643 Maintenance 24 hours Farm 6/6/2024 2024 Flare Flared 15.9 MCF - nothing Natural Gas Mcf 15.9 Maintenance 24 hours Rabbit Gulch 6/6/2024 2024 Flare Flared 19917 MCF - due to Plant and stations shutdowns. DOGM 8574 Natural Gas Mcf 19917 Maintenance 24 hours Ravolla 6/6/2024 2024 Flare Flared 16682 MCF - due to Plant and stations shutdowns. DOGM 8570 Natural Gas Mcf 16682 Maintenance 24 hours Farm 6/7/2024 2024 Flare Flared 595 MCF - due to C5 and C6 down for planned maintenance and high field pressure Natural Gas Mcf 595 Maintenance 24 hours Rabbit Gulch 6/7/2024 2024 Flare Flared 20039 MCF - due to Plant and stations shutdowns. DOGM 8574 Natural Gas Mcf 20039 Maintenance 24 hours Ravolla 6/7/2024 2024 Flare Flared 18948 MCF - due to Plant and stations shutdowns. DOGM 8570 Natural Gas Mcf 18948 Maintenance 24 hours Farm 6/8/2024 2024 Flare Flared 2082 MCF - due to high field pressure with plant shutdown. DOGM 8577 Natural Gas Mcf 2082 Maintenance 24 hours Rabbit Gulch 6/8/2024 2024 Flare Flared 19698 MCF - due to Plant and stations shutdowns. DOGM 8574 Natural Gas Mcf 19698 Maintenance 24 hours Ravolla 6/8/2024 2024 Flare Flared 17101 MCF - due to Plant and stations shutdowns. DOGM 8570 Natural Gas Mcf 17101 Maintenance 24 hours