HomeMy WebLinkAboutDAQ-2024-0085381
DAQC-592-24
Site ID 4575 (B4)
MEMORANDUM
TO: STACK TEST FILE – UINTA WAX OPERATING, LLC – Doc Tribal Battery
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Paul Bushman, Environmental Scientist
DATE: June 19, 2024
SUBJECT: Sources: One (1) Caterpillar 3306TA 168 hp engine; SN: 07Y08569
Contact: Kaylene Bridwell: 405-496-7308
Location: Uintah County, Utah
Test Contractor: Oasis Emission Consultants, Inc.
Permit/AO#: Permit by Rule
Action Code: TR
Subject: Review of stack test report dated June 10, 2024
On June 13, 2024, Utah Division of Air Quality (DAQ) received a test report for one (1) Caterpillar
3306TA 168 hp engine at Doc Tribal Battery, Uintah County, Utah. Testing was performed May 28,
2024, to demonstrate compliance with the emission limits found in Utah Administrative Code R307-510
and 40 CFR Part 60, Subpart JJJJ. The calculated test results are:
Source Test
Date Pollutant Method Tester Results DAQ Results Limits
Caterpillar
3306TA
SN: 07Y08569
May 28,
2024
NOx 7E 0.13 g/bhp-hr 0.128 g/bhp-hr 1.0 g/bhp-hr
CO 10 1.16 g/bhp-hr 1.157 g/bhp-hr 2.0 g/bhp-hr
VOC 25A 0.11 g/bhp-hr 0.111 g/bhp-hr 0.7 g/bhp-hr
DEVIATIONS: None.
CONCLUSION: The stack test report appears to be acceptable.
RECOMMENDATION: The emissions from the Caterpillar 3306TA 168 hp engine should be
considered to have been in compliance with the emission limits of UAC
R307-510 and 40 CFR Part 60, Subpart JJJJ during testing.
ATTACHMENTS: DAQ stack test review excel spreadsheets, Uinta Wax Operating, LLC
stack test report.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57