MEMORANDUM
TO: FILE – BERRY PETROLEUM COMPANY, LLC – LC Tribal 15-26-56
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Fred Goodrich, Environmental Scientist
DATE: September 15, 2023
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: September 15, 2023
SOURCE LOCATION: LC Tribal 15-26-56
Lat: 40.011952 Long: -110.524553
Business Office:
11117 River Run Boulevard
Bakersfield, CA 93311
SOURCE TYPE: Tank Battery
Duchesne County
API: 4301350871, 4301351381
SOURCE CONTACTS: Jon Armstrong, Corporate Environmental Contact
Phone: (661) 293-8211, Email: jarmstrong@bry.com
Matt Guest, Local Contact
Email: mguest@bry.com
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local gas
plant. The oil and process water in the storage tanks is loaded
into tanker trucks and hauled off site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart IIII, 40 CFR 60 Subpart
JJJJ, 40 CFR 60 Subpart OOOO.
, -
2
SOURCE EVALUATION: Site Type: PBR-Uncontrolled
No Flare Controls
Site powered by engine
The source registered: 2,241 Estimated Oil BBL.
DOGM current 12 month rolling production is: 3,063 BBLs.
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean Burn Make - Ajax
Model - E-565 Mfg Year - 2011 Horse Power - 40 Combustion -
Field Gas, Engine - Engine - Natural Gas 4-Stroke Rich Burn
Make - Arrow Model - C-101 Mfg Year - Post 2008 Horse
Power - 24.5 Combustion - Field Gas, Pneumatic, Tank
8 Pneumatic Controllers
9 Continuous bleed natural gas-driven pneumatic controllers are in compliance with 40 CFR 60.5390 or
60.5390a as applicable. Exemptions to tagging and record keeping requirements apply to controllers
existing before December 1, 2015. [R307-502-4]
In Compliance. This source does not use continuous bleed controllers as described in 40 CFR
60.5365(d)(1).
15 Oil and Gas Industry Registration Requirement
16 The source is registered with the DAQ. [R307-505-3(3)]
In Compliance.
17 Registration has been updated within 30 days of a company name change, removal or addition of
control devices, or termination of operations. [R307-505-3(3)]
In Compliance.
18 Storage Vessels
19 Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. All hatches were found closed at the start of the evaluation.
23 Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. The DAQ did not identify any modifications or unauthorized equipment.
24 Records for each of the following are kept for three years:
Storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if required
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled
per R307-506-4(2)[R307-506-5]
In Compliance. Records were observed at the local Berry Petroleum LLC office.
3
38 Natural Gas Engines
39 Engines subject to R307-510 (does not have an AO, began operations, installed or modified after
January 1, 2016) meet the following limits:
Maximum Engine hp Emission Standards in (g/hp-hr)
NOx CO VOC HC+NOx
>25 hp and < 100 hp - 4.85 - 2.83
>100 hp 1.0 2.0 0.7 -
[R307-510-4(1)]
In Compliance.
40 Affected engines are certified or have an initial performance test per 40 CFR 60.4244. [R307-510-4(2)]
In Compliance.
41 Affected engine exhaust vents are vertical and unrestricted.
Stacks are 8' or greater if the site horsepower rating is 151 to 305
Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)]
In Compliance. Upon inspection the engine exhaust stack vents were found correctly vertical.
42 Engine certifications or initial performance tests required are kept for the life of the engine at the
source. [R307-510-5]
In Compliance. Observed.
46 Visible Emissions
47 Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3]
In Compliance. No visible emissions were detected.
55 Emission Inventory:
56 An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. Berry Petroleum submitted for the 2020 emissions inventory.
58 NSPS (Part 60) IIII: Standards of Performance for Stationary Compression Ignition Internal
Combustion Engines [40 CFR 60 Subpart IIII]
In Compliance.
59 NSPS (Part 60) JJJJ: Standards of Performance for Stationary Spark Ignition Internal Combustion
Engines [40 CFR 60 Subpart JJJJ]
In Compliance.
4
60 NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance.
PREVIOUS ENFORCEMENT
ACTIONS: No enforcement actions within the past five years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to: LC Tribal 15-26-56:
In Compliance - This source was found to be clean and well-kept
with no visible or fugitive emissions. The source was inspected
by OGI camera and found to be free of leaks.
RECOMMENDATION FOR
NEXT INSPECTION: The DAQ has no recommendations for the next inspector other
than what are customary.