Loading...
HomeMy WebLinkAboutDAQ-2024-007492 Small Source Registration DAQE-EN161990001-24 {{$d1 }} Environmental Compliance Target Corporation PO Box 111 Minneapolis, MN 55440-0111 POC@target.com Dear Environmental Compliance: Re: Request for Evaluation of Compliance with Rule R307-401-9, UAC: Small Source Exemption Project Fee Code: N161990001 On February 21, 2024, the Division of Air Quality (DAQ) received your request for a small source exemption for Target Store T2904 (Provo Town Center Emergency Engine). The source is located at 1200 Towne Centre Boulevard, SPC A Provo, Utah County, 84601. According to your application, onsite equipment includes one (1) internal combustion engine to operate as an emergency generator. DAQ has determined the small source exemption applies to the source, as long as the equipment and associated processes operate as specified in the registration request. The small source exemption does not exempt a source from complying with other applicable federal, state, and local regulations and the current Utah Administrative Code. Based on the emissions that you submitted to DAQ with your registration request, Target Store T2904 is not required to obtain an approval order under R307-401. If you change your operation such that there is an increase in emissions, we recommend that you notify us, as an approval order may be required. As authorized by the Utah Legislature, the fee for issuing this small source exemption is a one-time filing fee in addition to the actual time spent by the review engineer and all other staff on the project. Payment should be sent to DAQ upon receipt of the invoice. 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director / % Û à Û Ù Û Ý DAQE-EN161990001-24 Page 2 Thank you for registering your source with the DAQ. If you have any additional questions, please contact Katie Andersen at (385) 515-1748 or kandersen@utah.gov. Sincerely, Bryce C. Bird Director {{$s }} Alan D. Humpherys, Manager New Source Review Section BCB:ADH:KA:jg {{#d1=date1_es_:signer1:date:format(date, "mmmm d, yyyy")}} {{#s=Sig_es_:signer1:signature}} Cummins C150N6 Emergency Generator Power Output: 240 hp Fuel Consumption Rate (100% Load): 1950 ft3/hr Hours of generator operation:50 hours Calculations Summary - Fuel : Natural Gas Emission Hourly Emission Daily Emission Maximum Factor1 Units Rate Rate Emissions (lbs/hr)(lbs/day)(tpy) PM2.5 0.01941 lb/MMBtu 3.86E-02 0.93 9.65E-04 PM10 0.01941 lb/MMBtu 3.86E-02 0.93 9.65E-04 CO2 0.49 g/bhp-hr 0.26 6.22 0.006 VOC2 0.20 g/bhp-hr 0.86 20.64 0.021 NOx2 0.04 g/bhp-hr 0.00 0.11 1.10E-04 SO2 5.88E-04 lb/MMBtu 1.17E-03 0.03 2.92E-05 Lead (PB)-------- H2S -------- 1 Emission factors obtained from AP-42, Table 3.3-2 (July 2000)Total 2 Exhaust Emission Data from Generac, assuming all THC as VOC Sample Calculations =0.0194 lbs/10^6 Btu x 1,020 Btu/scf x 1,950.0 cf/hr = 0.0386 lbs/hr Where: •1,020 Btu/scf is the heat content of natural gas obtained from AP-42 Chapter 3.2 (July 2000); •1,950 ft3/hr is the rate of fuel consumption obtained from the manufacturer, and •50 is the estimated average maximum hours the generator would run in a typical year Compound PM10 hourly emission rate: Maximum Emissions lbs/year 1.93 1.93 12.96 42.99 0.22 0.06 60.09 lbs/yr Cummins C150N6 Emergency Generator Power Output: 240 hp Their PM Emission Facto Fuel Consumption Rate (100% Load): 1950 ft3/hr Hours of generator operation:50 hours Calculations Summary - Fuel : Natural Gas Emission Hourly Emission Daily Emission Maximum Factor1 Units Rate Rate Emissions (lbs/hr)(lbs/day)(tpy) PM2.5 3.84E-02 lb/MMBtu 7.64E-02 1.83 1.91E-03 PM10 3.84E-02 lb/MMBtu 7.64E-02 1.83 1.91E-03 CO2 0.49 g/bhp-hr 0.26 6.22 0.006 VOC2 0.20 g/bhp-hr 0.11 2.54 0.003 NOx2 0.04 g/bhp-hr 0.02 0.51 5.29E-04 SO2 5.88E-04 lb/MMBtu 1.17E-03 0.03 2.92E-05 Lead (PB)-------- H2S -------- 1 Emission factors obtained from AP-42, Table 3.3-2 (July 2000)Total 2 Exhaust Emission Data from Generac, assuming all THC as VOC Sample Calculations =0.0384 lbs/10^6 Btu x 1,020 Btu/scf x 1,950.0 cf/hr = 0.0764 lbs/hr Where: •1,020 Btu/scf is the heat content of natural gas obtained from AP-42 Chapter 3.2 (July 2000); •1,950 ft3/hr is the rate of fuel consumption obtained from the manufacturer, and •50 is the estimated average maximum hours the generator would run in a typical year Compound PM10 hourly emission rate: 0.01941 Maximum Emissions lbs/year 3.82 3.82 12.96 5.29 1.06 0.06 27.01 lbs/yr 2020 6.2 2019 15.6 2018 19.6 41.4 13.8