HomeMy WebLinkAboutDAQ-2024-0069761
DAQC-274-24
Site IDs: 15836, 15733, 15616,
15692, 15714, 15534,
15891, and 15654 (B4)
MEMORANDUM
TO: STACK TEST FILE – UINTA WAX OPERATING, LLC – Coleman
13-28-3-1E-H1, Coleman Cordova 14-28-3-1E-H1 and Coleman Tribal
3-33-3-3E-H1, Deep Creek 11-22-4-2E, Hicken Tribal 2-16-3-1E-H1 and
Hicken Tribal 15-9-3-1, Jenks Tribal 2-16-21-3-2E-H1, Kendall Tribal 1-13-3-1W,
LC Tribal 8-23D-46, and Winn 2-21-3-1E-H1 – Uintah and Duchesne Counties
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Kyle Greenberg, Environmental Scientist
DATE: March 19, 2024
SUBJECT: Sources: Nine (9) Arrow L-795 pumpjack engines; SN’s: FDL795006,
CHL795001, CLL795004, L-600966, L600737, DDL7950002,
CHL795004, L-600846, and SP114P1
Location: Remote Locations in Uintah and Duchesne Counties, Utah
Contact: Karen Pratt: (720) 990-9927
Tester: Oasis Emissions Consultants, Inc.
Site ID #: 15836, 15733, 15616, 15692, 15714, 15534, 15891, and 15654
Permit/AO #: Permit by Rule
Subject: Review of Pretest Protocol dated March 16, 2024
On March 16, 2024, Utah Division of Air Quality (DAQ) received a protocol for the testing of nine (9)
Arrow L-795 pumpjack engines at Coleman 13-28-3-1E-H1, Coleman Cordova 14-28-3-1E-H1 and
Coleman Tribal 3-33-3-3E-H1, Deep Creek 11-22-4-2E, Hicken Tribal 2-16-3-1E-H1 and Hicken Tribal
15-9-3-1, Jenks Tribal 2-16-21-3-2E-H1, Kendall Tribal 1-13-3-1W, LC Tribal 8-23D-46, and Winn
2-21-3-1E-H1 Tank Batteries in Uintah and Duchesne Counties, Utah. Testing will be performed April
19, 2024, through May 3, 2024, to determine compliance with the emission limits found in 40 CFR part
60 subpart JJJJ.
PROTOCOL CONDITIONS:
1. Method 1 used to determine sample traverses: OK
2. Method 3A used to determine dry molecular weight of the gas stream: OK
3. Method 4 used to determine the moisture content within the gas stream: OK
4. Method 7E used to determine NOx emissions: OK
5. Method 10 used to determine CO emissions: OK
2
6. Method 18 used to determine ethane and methane concentrations of the gas stream: OK
7. Method 19 used to determine exhaust effluent flows and mass emission rates: OK
8. Method 25A used to determine VOC emissions: OK
DEVIATIONS: None stated in the protocol.
CONCLUSION: The protocol appears to be acceptable.
RECOMMENDATION: The test methods stated in the protocol are sufficient to determine NOx,
CO, and VOC emission rates and concentrations.
ATTACHMENTS: Uinta Wax Operating, LLC’s notification letter and pretest protocol.
March 16, 2024
Utah Department Of Environmental Quality
Division of Air Quality
PO Box 144820
Salt Lake City, UT 84114-4820
RE: Compliance Test Notification / Protocol Submission For Uinta Wax Operating,
LLC’s Various Facilities in Utah
Oasis Emission Consultants, Inc. has been requested to conduct compliance emission testing on
nine (9) 65 horsepower (hp) Arrow L-795 engines located at Uinta Wax Operating, LLC’s
Various Facilities in Utah. The engines are being tested in accordance with Utah Administrative
Code Rule R307-510-4 and EPA 40 CFR 60, Subpart JJJJ. A summary of the units and details of
our testing procedures can be found in the attached protocol.
The engines have been scheduled with the client for the Friday, April 19th, 2024; Monday, April
22nd, 2024 – Friday, April 26th, 2024; and Monday, April 29th, 2024 – Friday, May 3rd, 2024
test campaign.
If you have any questions or concerns, please contact the undersigned at (307) 382-3297.
Sincerely,
Oasis Emission Consultants, Inc.
__________________________
Christopher N. Knott, P.Eng
Director, Engineering & Operations
enc.
Utah Department of Environmental Quality
Division of Air Quality
Compliance Test Protocol
Engines: (9) Arrow L-795
Uinta Wax Operating, LLC
25 HP – 100 HP Engines
In Utah
March 16, 2023
Prepared By:
Oasis Emission Consultants, Inc.
2730 Commercial Way
Rock Springs, WY 82901
1.0 INTRODUCTION
The purpose of this document is to provide relevant information pertaining to proposed
compliance emission testing for Uinta Wax Operating, LLC by Oasis Emission Consultants, Inc.
The units are classified as non-emergency stationary engines rated below 100 horsepower (hp).
The engines are being tested in accordance with the Utah Administrative Code Rule R307-510-4
and EPA 40 CFR 60, Subpart JJJJ.
1.1 TEST PROGRAM ORGANIZATION
Facilities: Coleman 13-28-3-1E-H1,
Coleman Cordova 13.5, 14-28-3-1E-H1,
Deep Creek 11-22-4-2E,
Hicken Tribal 15-9-4-3-1E-H1 & 2-16-3-1E-H1,
Jenks Tribal 2-16-3-2E-H1,
Kendall Tribal 1-13-3-1W-H1,
LC Tribal 8-23D-46
& Winn 13.5-10-3-1E-H1
Wells: Coleman 13-28-3-1E-H1,
Coleman Cordova 13.5-28-3-1E-H1,
Coleman Cordova 14-28-3-1E-H1,
Deep Creek 11-22-4-2E,
Hicken Tribal 2-16-3-1E-H1,
Jenks Tribal 2-16-3-2E-H1,
Kendall Tribal 1-13-3-1W-H1,
LC Tribal 8-23D-46
& Winn 13.5-10-3-1E-H1
CAERS IDs: 15836,
15733,
15616,
15692,
15714,
15534,
15891
& 15654
Client: Uinta Wax Operating, LLC
Contact: Karen Pratt, Regulatory Manager
Email: KPratt@finleyresources.com
Cell.: (720) 990-9927
Contact: Josh Morgan
Email: JMorgan@finleyresources.com
Cell.: (817) 231-8756
Test Company: Oasis Emission Consultants, Inc.
Address: 2730 Commercial Way
Rock Springs, WY 82901
Contact: Christopher Knott, P.Eng., Director, Engineering & Operations
Phone: (307) 382-3297 Fax: (307) 382-3327
State Authority: Utah Department Of Environmental Quality
Address: PO Box 144820
Salt Lake City, UT 84114-4820
Contact: Rik Ombach, Minor Source Compliance Manager
Email: rombach@utah.gov
Phone: (801) 536-4164
Stack Test Report Submission:
https://utahgov.co1.qualtrics.com/jfe/form/SV_3dSxf7JSzy4jwGh
1.2 Test Project Objective(s)
The engines located at Uinta Wax Operating, LLC’s facilities in Utah are being tested in
accordance with the Utah Administrative Code Rule R307-510-4 and EPA 40 CFR 60, Subpart
JJJJ.
2.0 SOURCE TEST PROGRAM DESCRIPTION
2.1 Test Contractor
All source emission tests will be performed by Oasis Emission Consultants, Inc., based out of
Rock Springs and Sheridan, Wyoming. Processed test results and all raw data captured during the
tests are forwarded to Chris Knott, P.Eng., Director of Engineering and Operations and/or
Charles Chapman, Manager of Technical Services, for quality control and data checking. Once
approved, tests are forwarded to the client.
2.2 Test Dates
The units will be tested by Oasis Emission Consultants, Inc. during the April 19th, 2024; April
22nd – 26th, 2024 and April 29th – May 3rd, 2024 test campaign.
2.3 Report Date
The compliance test reports will be submitted no later than 60 days following the compliance
tests.
2.4 Emission Source Description
A summary of the units to be tested is provided in the table below:
*The serial numbers will be provided in the final reports, if currently unavailable.
Facility Well CAERS ID County Latitude /
Longitude
Engine Serial
Number*
HP
Coleman 13-28-3-1E-H1 Coleman 13-28-3-1E-H1 15836 Uintah 40.18502,
-109.8977
Arrow L-795 FDL795006 65
Coleman Cordova 13.5, 14-28-3-
1E-H1
Coleman Cordova 13.5-28-3-1E-H1 15733 Uintah 40.18478,
-109.8876
Arrow L-795 CHL795001 65
Coleman Cordova 14-28-3-1E-H1 Arrow L-795 CLL795004 65
Deep Creek 11-22-4-2E Deep Creek 11-22-4-2E 15616 Uintah 40.12078,
-109.7563
Arrow L-795 L-600966 65
Hicken Tribal 15-9-4-3-1E-H1 &
2-16-3-1E-H1
Hicken Tribal 2-16-3-1E-H1 15692 Uintah 40.23112,
-109.8863
Arrow L-795 L600737 65
Jenks Tribal 2-16-3-2E-H1 Jenks Tribal 2-16-3-2E-H1 15714 Uintah 40.23129,
-109.7713
Arrow L-795 DDL7950002 65
Kendall Tribal 1-13-3-1W-H1 Kendall Tribal 1-13-3-1W-H1 15534 Uintah 40.22913,
-109.9398
Arrow L-795 CHL795004 65
LC Tribal 8-23D-46 LC Tribal 8-23D-46 15891 Duchesne 40.11982,
-110.5234
Arrow L-795 L-600846 65
Winn 13.5-10-3-1E-H1 Winn 13.5-10-3-1E-H1 15654 Uintah 40.23007,
-109.8715
Arrow L-795 SP114P1 65
2.4.1 Utah Administrative Code Rule R307-510-4 Standards
In accordance with the Utah Administrative Code Rule R307-510-4 from the Oil and Gas
Industry: Natural Gas Engine Requirements (510), testing will be conducted to show levels in
units of HC+NOx and CO (as g/BHp-hr).
2.4.2 EPA 40 CFR 60, Subpart JJJJ Standards
According to the requirements of EPA 40, CFR 60 Subpart JJJJ § 60.4233(d), non-emergency
stationary SI ICE manufactured after July 1st, 2008, and rated between 25 hp and 100 hp must
comply with the requirements of the standards for field testing listed in 40 CFR § 1048.101(c).
Under 40 CFR § 1048.101(c)(2) the HC + NOx standard is 3.8 g/KW-hr (2.8 g/BHp-hr) and the
CO standard is 6.5 g/kW-hr (4.8 g/BHp-hr). For natural gas-fueled engines, owners and operators
are not required to measure non-methane hydrocarbon emissions or total hydrocarbon emissions
to show that the engines meet the emission standards; that is, HC is assumed to equal zero.
Emission Measurement Methodologies:
The units will be tested according to EPA 40 CFR 60 (A), Methods 1, 3A, 4, 7E, 10, 18, 19 and
25A. Method 18 grab bags will be utilized to account for Methane and Ethane contents for the
determination of NMNEHC. Emissions in terms of g/BHp-hr will be converted from ppm levels
using the formulae from the Wyoming/Colorado portable analyzer protocol and a BSFC factor
(BTU/BHp-hr). Three, one hour tests will be conducted on each engine.
Operating Parameters:
Operating parameters, where applicable, will be recorded for each 1 hour test which may include
engine rpm, air/fuel ratio setting(s), suction/discharge pressures, ect.
Engine Load Approximation:
Oasis Emission Consultants, Inc. will approximate the engine load using the measured process
parameters, such as gas throughput, suction/discharge pressure/temperature; by correlating the
intake manifold conditions with the engine manufacture heat balance data; or, the engine load.
Maximum Engine hp HC+NOX CO
Equal to or greater than 25 hp
and < 100 hp
2.83 g/BHp-hr 4.85 g/BHp-hr
Maximum Engine Power NOX CO
Greater than 19 KW (25 hp)
and less than 75 KW (100)
(except gasoline and rich burn
engines that use LPG)
2.8 g/BHp-hr
(3.8 g/kW-hr)
4.8 g/BHp-hr
(6.5 g/kW-hr)
It is expected that the performance tests will be conducted within ±10% of 100% peak, or the
highest achievable load.
Test Methods:
All EPA test methods that we intend to utilize are listed below.
EPA 40 CFR 60 Appendix A, Method 1: Method 1 requires measurement of the various
physical attributes of a stack to establish appropriate sampling locations. An O2 stratification
check will be performed according to 8.1.2 of Method 7E prior to testing to determine
sampling location for engines with stack diameters greater than 6 inches, but less than 12
inches. For stacks equal to or greater than 12 inches in diameter, if the sampling port
locations meet the minimum Method 1 criterion for distance from disturbances, sampling
may be conducted at three points. If sampling ports do not meet Method 1 criterion for
distance from disturbances, stacks equal to or greater than 12 inches in diameter will have an
O2 stratification check performed to determine sampling locations. An O2 stratification is not
required for engines with a stack diameter less than 4 inches.
EPA 40 CFR 60 Appendix A, Method 3A: O2 measurements will be conducted using an
instrumental analyzer according to Method 3A. The O2 levels will be used in conjunction
with Method 19 to determine the overall exhaust effluent flow.
EPA 40 CFR 60 Appendix A, Method 4: Method 4 allows for the evaluation of the
moisture content within the effluent stream. A sample of the effluent stream is extracted at a
constant rate. The water is condensed from the stream through a series of impingers
surrounded by an ice bath. The total mass of the water condensed and the total volume of gas
measured are used to calculate the moisture content within the exhaust effluent stream.
EPA 40 CFR 60 Appendix A, Method 7E: Method 7E is the instrumental method for
measuring the NOx concentration in the effluent stream. After passing through a sample
conditioning system, NOx concentration is measured by a chemiluminescent gas analyzer.
The analyzer is calibrated using EPA Protocol G1 gas before and after each one hour test
run.
EPA 40 CFR 60 Appendix A, Method 10: Method 10 is the instrumental method for
measuring the CO concentration in the effluent stream. After passing through a sample
conditioning system, CO concentration is measured by a NDIR gas analyzer. The analyzer is
calibrated using EPA Protocol G1 gas before and after each one hour test run.
EPA 40 CFR 60 Appendix A, Method 18: Method 18 employs an integrated grab bag
sampling system. Method 18 will be utilized to account for Ethane and Methane
concentrations to determine NMNEHC.
EPA 40 CFR 60 Appendix A, Method 19: The BSFC factor and the measured Oxygen
content will be used to arrive at the overall exhaust effluent flow.
EPA 40 CFR 60 Appendix A, Method 25A: Total Hydrocarbons will be measured on a hot-
wet basis by using a Flame Ionization Analyzer. This analyzer will be calibrated using EPA
Protocol G1 Propane (C3) gas before and after each one hour test run.