HomeMy WebLinkAboutDAQ-2024-004351 1 DAQC-1357-23 Site ID 16015 (B5) MEMORANDUM TO: FILE – HOLLY ENERGY PARTNERS – Light Oil Dock THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Rob Leishman, Environmental Scientist DATE: December 18, 2023 SUBJECT: Holly Energy Partners, Light Oil Dock (Holly LOD), Major, MACT, SIP, Title V, Davis County, FRS #UT00000049001100013 INSPECTION TYPE: State Electronic Data Report (SEDR) Review REVIEW DATE: December 18, 2023 SOURCE LOCATION: West Bountiful/Davis County SOURCE CONTACT: Daria Underwood – 214-954-3935 APPLICABLE REGULATIONS: October 17, 2007 – DAQE-AN010123 0023B-07 - Approval Order SOURCE INSPECTION EVALUATION: With the exception of sources that only monitor for opacity, quarterly report memoranda will only address the findings of the quarterly report. Approval Order and Title V permit conditions addressing continuous emission monitoring requirements will be addressed in Holly LOD’s relative accuracy performance specification test review memorandum. SOURCE REVIEW EVALUATION: Third Quarter 2023 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation LOD 2203 VOC 99% 09/20/23 12/14/22 LOD VOC 0.00 10000 ppm - 6-hour RA Excess Emission Report - Hourly Summary Point Source Channel Startup & Shutdown Control Equipment Problems Process Problems Other Known Causes Unknown Causes Emission Limit LOD VOC 0 0 0 0 0 10000 ppm - 6-hour RA 1 8 2 2 CMS Performance Summary - Hourly Summary Point Source Channel Monitor Malfunction Non-monitor Malfunction QA Calibrations Other Known Causes Unknown Causes LOD VOC 0 0 12 0 0 Pollutant Concentration Exceeded Span of CEM Monitor Outage During Point Source Operation Alternate Sampling CEM Modifications 0 Hours 0 Hours 0 Hours 0 Events SOURCE INSPECTION SUMMARY EVALUATION: Holly LOD maintains its CEMS as required in R307-170 and 40 CFR 60.13. CURRENT RECOMMENDATIONS: All deviations appear to be a result of breakdown or process related problems that do not warrant issuing a violation. Holly LOD was in compliance during this reporting period. No further enforcement action is necessary. Holly LOD’s NSPS monitoring system meets the performance standards of 40 CFR 60, Appendix B Performance Specifications. HIGH PRIORITY VIOLATOR (HPV): No RECOMMENDATION FOR NEXT INSPECTION: Check DAS for daily zero and span drift. Check the QC program to ensure that monitor drift is being tracked and that the source can identify excessive drift. ATTACHMENTS: Excel spreadsheet review Corporate Office: 2828 N. Harwood, Suite 1300 Dallas, TX 75201-1507 214-871-3555 Operations Office: 1602 West Main Street Artesia, NM 88210 575-748-4000 December 12, 2023 Utah Division of Air Quality 195 North 1950 West Salt Lake City Utah 84116 Re: 3rd Quarter 2023 CEMS Report - Revised Woods Cross Terminal, Approval Order DAQE-AN010120023B-07 Holly Energy Partners Dear Sir/Madam: Enclosed please find a revised Q3-2023 Woods Cross Terminal Continuous Emission Monitoring System (CEMS) Report. Per Utah Administrative Code R307-170-9, the electronic ASCII report file was sent to Rob Leishman, UDAQ, on December 12, 2023, via e-mail. Upon further review of the facility data, it was determined that hours for planned and unplanned maintenance during the quarter were incorrectly entered under Code 310 on the UDAQ report submitted on October 30, 2023 for this reporting period as explained below. The following information is applicable to report contents: 1. The continuous monitoring system calibration and drift checks were routinely performed, and a quarterly cylinder gas audit (CGA) was completed on 9/20/2023 and found within the required performance specifications. 2. The data used to show compliance with the standard were obtained in accordance with approved methods and procedures. 3. The minimum data capture requirements have been met. 4. CEMs downtime was 0.53% related to daily calibrations and quarterly CGAs. 5. VRU and supporting equipment required approximately 116 hours of maintenance and downtime for the third quarter for planned routine and unplanned maintenance. During the VRU maintenance and downtime periods during this reporting quarter, the operations at the loading rack were either discontinued or loading rack emissions were rerouted to the VCU. Therefore, no excess emissions occurred. This is a correction to the original CEMs report submitted on October 30, 2023 in which the 116 hours of VRU maintenance and downtime periods were reported as excess emissions under Code 310. 6. Compliance with the general requirements under Utah Administrative Code R307-170-5 has been achieved during the reporting period. I certify under penalties of law that, based upon inquiry of personnel involved, and to the best of my knowledge, the statements and information contained in this report are truthful and accurate, and are a complete record of all monitoring-related events that occurred during the reporting period. If you have any questions or need additional information, please contact me at (214) 954-6690. Sincerely, Jason Leik Environmental Manager Attachment: (1/1) Revised HEP CEMS EER Worksheet, 3rd Quarter 2023 Attachment: HEP CEMS EER Worksheet, 3rd Quarter 2023 (Note: A copy of the attached EER worksheet, in CSV format, was submitted to Mr. Rob Leishman on December 12, 2023, via email from Tawnya Chott, ERM, on behalf of HEP.) 100 Mark T CuHolly Ener P.O. Box 126 Artesia, New M011-00013 (214) 954-6690 Jason Leik 110 LOD 3 2023 2203 200 LOD VOC IR 8400D 5086 5000 20,000 8/8/2016 VRU 220 LOD VOC 230 LOD VOC 0 0 0 0 250 LOD VOC 12/14/2022 12/9/2021 12 ppm 1,181 1,333 3.26%pass 260 LOD VOC 9/20/2023 1 FF6611 8/12/2024 Certified Mpercent 0.513 0.508 1.05%pass low 260 LOD VOC 9/20/2023 2 FF37299 8/12/2024 Certified Mpercent 1.100 1.123 -2.05%pass mid 300 LOD VOC 0.53%11.75 0 0 11.75 0 0 310 LOD VOC 0 0.00%0 0 0 0 0 10000 ppm 6 hour RA 460 LOD VOC NA NA 0 700 701 Startup/Shutdown 700 702 Control Equipment Problems 700 703 Process Problems 700 704 Other Known Causes 700 705 Unknown Causes 720 721 Monitor Equipment Malfunction 720 722 Nonmonitor Equipment Malfunction 720 723 QA Calibrations 720 724 Other Known Causes 720 725 Unknown Causes 730 703 A Power failure. 730 703 B Control valve failure. 730 703 C Pump failure 730 704 A Other known causes. Refinery product process change for winter grades 730 705 A Unknown cause. 730 721 A Daily calibration check exceedance. Cause of drift unknown. Recalibrated instrument. 730 721 B Data recorder failure. 730 721 C Power failure. No loading during outage. 730 721 D Monitor failure 730 722 A VRU Equipment failure. VCU used for control. 730 723 A (QA/QC) - VCU used for control. 730 724 A Meter proving. VCU used for control. 730 724 B VRU maintenance. VCU used for control. 730 724 C Monitor maintenance. Review Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No 1 Type Code 100 (Company Information)Type Code Company Manager Company Name AIRS # Phone Number Environmental Contact 1 100 Mark T Cunningham 01100013 (214) 954-6690 Jason Leik0 1 100 0 0 0 0 1 Type Code 110 (Point Source Identification)Type Code Point Source Quarter 1 - 4 Year Point Source Operating Hrs. in Quarter 1 110 3 2023 2203 1 110 0 0 0 1 Type Code 200 (Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date Monitor Location 1 200 VOC IR 8400D 5086 5000 20000 8/8/2016 VRU 1 200 0 0 0 0 0 0 1/0/1900 0 1 Type Code310 (Excess Emissions) SUMMARY REPORT Type Code Channel Total Hours of Excess Emissions Excess Emissions - % of Total Operating Hours RC 701 Hours - start up/Shutdown RC 702 Hours- Control Equipment Problems RC 703 Hours - Process Problems RC 704, 706, 707 Hours -Other Known Causes RC 705 Hours - Unknown Causes Emission Limitation Emission Limitation Units Emission Limitation Averaging Period 1 TRUE 310 VOC 0 0.00% 0 0 0 0 0 10000 ppm 6 hour RA 1 310 0 0 0 0 0 0 0 0 0 1 Type Code 300 (CMS Performance Summary) Type Code Channel Point Source Operating Hours Downtime - % of Total Operating Hours Total CMS Downtime RC 721 Hours - Monitor Malfunction RC 722 Hours - Non-monitor Malfunction RC 723 Hours - QA Calibrations RC 724 Hours - Other Known Causes RC 725 Hours - Unknown Causes 1 TRUE 300 VOC 2203 0.53% 11.75 0 0 11.75 0 0 1 300 0 0 0 0 0 0 1 Type Code 250 (Performance Specification RATA Results) Type Code Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units of Measurement CEM Value Reference Method Value Relative accuracy Pass/ Fail 1 370 Days 250 VOC 12/14/22 12/09/21 12 ppm 1181 1,333 3.26% pass 1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0 1 Type Code 260 (CGA Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 Valid Cal. Gas 260 VOC 09/20/23 1 FF6611 08/12/24 Certified Master Gas percent 5130 5080 1.05% pass low 1 Valid Cal. Gas 260 VOC 09/20/23 2 FF37299 08/12/24 Certified Master Gas percent 11000 11230 -2.05% pass mid 1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 1 Type Code 270 (Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 1 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code Channel Start Date Start Time End Date End Time Hours 1 0 0 0 1/0/00 0:00 1/0/00 0:00 1 1 None Reported 1 0 TC 220 Hours 0.00 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00 1 11.75 TC 300 Hours 11.75 FALSE Yes None Reported None Reported None Reported None Reported None Reported Point Source Point Source Point Source Point Source Point Source Point Source Yes LOD 0 LOD LOD LOD 0 Type Code 550 (Changes in Operation in Control Equipment When CEM Data Not Available) Type Code 500 (Boiler Operating Days w/o 18 Hours of Data) Holly Energy Partners Operating, L.P. 0 Type Code 450 (Data Excluded) LOD 0 LOD 0 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code 220 (Monitor Outage During Point Source Operation) Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) Type Code 240 (CEM Modifications) Type Code 530 (Excess Emissions During Emergency Conditions) 0 LOD 0 0 0 Review Relative Accuracy Overview Point Source Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units Measured CEM Value Reference Method Value Relative Accuracy Pass/ Fail 2023 LOD VOC 12/14/22 12/09/21 12 ppm 1181 1333.00 3.26% pass * NSPS CGA Third 2023 Audit Gas Ranges Audit Gas Ranges AP1 Low AP2 Low AP1 High AP2 High LOD VOC 9/20/23 20000 5080 4000 to 6000 LOD VOC 9/20/23 20000 11230 10000 to 12000 Point Source Channel Audit Date Low Span Audit Gas Used High Span Audit Gas Used Review Monitoring Information TC 210, 230, & 240 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) - 500 (All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All) * Sum of Hours Column Labels Row Labels (blank) VOC Grand Total (blank)0 0 LOD 0 0 Grand Total 0 0 0 * Type Code 240 (CEM Modifications) - 100 (All) * Count of Channel Column Labels Row Labels (blank) Grand Total (blank) (blank) Grand Total Review Type Code 220 (Monitor Outage During Point Source Operation) - 600 (All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank) (blank) 0 0 LOD VOC 0 0 0 Grand Total 0 0 Review VOC/THC * VOC/THC Type Code 460 (VOC/THC) - 6000 (All) VOC/THC * VOC/THC Count of Magnitude of Emissions Column Labels VOC/THC Row Labels 0 Grand Total VOC/THC LOD VOC/THC #N/A 1 1 VOC/THC Grand Total 1 1 Review Type Code 500 Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of Data) After February 28, 2005 (90% Operating Hours For each 30 BOD) - 500 (All) * Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 510 (F-factor, Equations & Conversion Factors) - 500 (All) Count of F-factor Column Labels Row Labels Grand Total Grand Total * Type Code 520 (Minimum Data Not Obtained <22/30 BODs) - 500 (All) Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 530 (Excess Emissions During Emergency Conditions) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * Type Code 540 (Fuel Pre-treatment Credit SO2) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * TypeCode 550 (Changes in Operation in Control Equipment When CEM Data Not Available) - 500 (All) Column Labels Row Labels Grand Total Grand Total