HomeMy WebLinkAboutDAQ-2024-0073641
DAQC-PBR155170001-24
Site ID 15517 (B1)
MEMORANDUM
TO: FILE – OVINTIV USA INC. – Ute Tribal 10-14-4-1W
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager
FROM: Stephen Foulger, Environmental Scientist
DATE: February 21, 2024
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: January 31, 2024
SOURCE LOCATION: Ute Tribal 10-14-4-1W
Lat: 40.13375 Long: -109.96057
Business Office:
370 17th Street, Suite 1700
Denver, CO 80202
SOURCE TYPE: Tank Battery
Uintah County
API: 4304751424
SOURCE CONTACTS: Brandon Lithgoe, Local Contact
Phone: (281) 847 6093, Email: Brandon.Lithgoe@ovintiv.com
Ryan Zillner, Local Contact
Phone: 720-876-3144, Email: ryan.zillner@ovintv.com
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local gas
plant. The oil and process water in the storage tanks is loaded
into tanker trucks and hauled off-site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart JJJJ, 40 CFR 60 Subpart
OOOO.
2
SOURCE EVALUATION: Site Type: PBR-Uncontrolled
No Flare Controls
Site powered by Engine
The source registered: 7,999 Estimated Oil BBL.
DOGM current 12 month rolling production is: 1,000
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean Burn Make - Ajax
Model - E-565 Mfg Year - 2014 Horse Power - 40 Combustion -
natural gas, Pneumatic, Tank
15
General Provisions
VOC emissions are minimized as reasonably practicable by equipment design, maintenance and
operation practices. [R307-501-4(1)]
Out of Compliance. Emissions found coming from produced water tank thief hatch, oil tank
stack valve, and separator shed pneumatic control.
Oil and Gas Industry Registration Requirement
16 The source is registered with the DAQ. [R307-505-3(3)]
In Compliance. This source was found properly registered at the time of inspection.
17 Registration has been updated within 30 days of a company name change, removal or addition of
control devices, or termination of operations. [R307-505-3(3)]
In Compliance. This source was found properly registered at the time of inspection.
18 Storage Vessels
19 Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. Thief hatches found closed and latched at the time of inspection.
23 Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. The combustor was removed from this source after production dropped to an
appropriate level.
24 Records for each of the following are kept for three years:
Storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if required
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled
per R307-506-4(2)[R307-506-5]
In Compliance. These records were reviewed and found to be compliant at the time of inspection.
38
3
46 Visible Emissions
47 Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3]
In Compliance. No visible emissions were observed at the time of inspection.
48
55 Emission Inventory:
56 An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. Source found properly submitted in the 2020 emissions inventory.
59 NSPS (Part 60) JJJJ: Standards of Performance for Stationary Spark Ignition Internal Combustion
Engines [40 CFR 60 Subpart JJJJ]
In Compliance.
60 NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance.
PREVIOUS ENFORCEMENT
ACTIONS: No enforcement actions within the past five years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to Ute Tribal 10-14-4-1W:
Out of Compliance - This source was found non-compliant at the
time of inspection. Recommend to increase inspection
frequency. If this source is found non-compliant in subsequent
inspections a compliance advisory should be issued.
RECOMMENDATION FOR
NEXT INSPECTION: Recommend to increase inspection frequency. If this source is
found non-compliant in subsequent inspections a compliance
advisory should be issued.
ATTACHMENTS: