HomeMy WebLinkAboutDAQ-2024-0077731 DAQC-374-24 Site ID 15738 (B4) MEMORANDUM TO: STACK TEST FILE – XCL ASSETCO, LLC – Butcher Butte Pad 27-4D-23 (Miles Facility) THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Paul Bushman, Environmental Scientist DATE: April 23, 2024 SUBJECT: Sources: One (1) Waukesha L5794GSI engine Contact: Lauren Brown: (713) 808-9406 Location: Duchesne County, UT Test Contractor: Oasis Emission Consultants, Inc. Permit/AO#: Permit by Rule Action Code: TR Subject: Review of stack test report dated February 9, 2024 On April 19, 2024, Utah Division of Air Quality (DAQ) received a test report for one (1) Waukesha L5794GSI engine at Butcher Butte Pad 27-4D-23 (Miles Facility), Duchesne County, UT. Testing was performed February 6, 2024, to demonstrate compliance with the emission limits found in Utah Administrative Code R307-510 and 40 CFR Part 60, Subpart JJJJ. The calculated test results are: Source Test Date Pollutant Method Tester Results DAQ Results Limits Waukesha L5794GSI SN: C-13804/1 February 6, 2024 NOx 320 0.34 g/bhp-hr 0.335 g/bhp-hr 1.0 g/bhp-hr CO 320 0.68 g/bhp-hr 0.680 g/bhp-hr 2.0 g/bhp-hr VOC 320 0.01 g/bhp-hr 0.010 g/bhp-hr 0.7 g/bhp-hr DEVIATIONS: None. CONCLUSION: The stack test report appears to be acceptable. RECOMMENDATION: The emissions from the Waukesha L5794GSI engine should be considered to have been in compliance with the emission limits of UAC R307-510 and 40 CFR Part 60, Subpart JJJJ during testing. ATTACHMENTS: DAQ stack test review excel spreadsheets; XCL AssetCo, LLC stack test report. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50