Loading...
HomeMy WebLinkAboutDAQ-2024-0051381 DAQC-PBR156080001-24 Site ID 15608 (B1) MEMORANDUM TO: FILE – UINTA WAX OPERATING, LLC – Coleman Tribal 8-33-3-1E THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Chris Jensen, Environmental Scientist DATE: February 20, 2024 SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION INSPECTION DATE: February 14, 2024 SOURCE LOCATION: Coleman Tribal 8-33-3-1E Lat: 40.181667 Long: -109.881688 Business Office: 5128 Apache Plume Road, Suite 300 Fort Worth, TX 76109 SOURCE TYPE: Tank Battery Uintah County API: 43047-54041 SOURCE CONTACTS: Aimee Cole, Local Contact Phone: 720-384-7365, Email: acole@finleyresources.com Kaylene Bridwell, Corporate Environmental Contact Phone: 405-496-7308, Email: kaylene.bridwell@uintawax.com OPERATING STATUS: Operating PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products go through a separator where the oil and any water products are sent to storage tanks and the gas is used to power equipment on site (pump jack engine, tank heater, separator, flare, combustor, etc.) Any remaining gas is sent to a pipeline that feeds a local gas plant. The oil and process water in the storage tanks is loaded into tanker trucks and hauled off site for processing and disposal. APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and Gas Industry, and UAC R307-201: Emission Standards: General Emission Standards; and UAC R307-150: Emission Inventories, and 40 CFR 60 Subpart JJJJ. 2 SOURCE EVALUATION: Site Type: PBR-Controlled Voluntarily Controlled by Flare Site powered by Engine DOGM current 12 month rolling production is: 5,388 BBLs. Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls. 8 Pneumatic Controllers 9 Continuous bleed natural gas-driven pneumatic controllers are in compliance with 40 CFR 60.5390 or 60.5390a as applicable. Exemptions to tagging and record keeping requirements apply to controllers existing before 12/1/2015. [R307-502-4] In Compliance. This source does not use continuous bleed natural gas-driven pneumatic controllers. 11 Oil and Gas Industry: General Provisions [R307-501] Out of Compliance. The thief hatch on the center tank was found to be leaking fugitive emissions. The repairs have been made and component has returned to service. See email attachment. 15 Oil and Gas Industry Registration Requirement 16 The source is registered with the DAQ. [R307-505-3(3)] In Compliance. 17 Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. 18 Storage Vessels 19 Thief hatches are kept closed and latched. [R307-506-4(1)] In Compliance. All hatches were found closed at the start of the evaluation. 23 Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2). [R307-506-4(6)] In Compliance. The DAQ did not identify any modifications or unauthorized equipment. 24 Records for each of the following are kept for three years: Storage vessel vent system inspections (openings, thief hatches, pressure relief devices, bypasses, etc.), if required Monthly crude oil throughput Emission calculations, actuals and sampling data when used to justify an exemption to storage vessel rules Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled per R307-506-4(2)[R307-506-5] In Compliance. Monthly production totals were supplied to the DAQ. See email attached. 3 38 Natural Gas Engines 39 Engines subject to R307-510 (does not have an AO, began operations, installed or modified after January 1, 2016) meet the following limits: Maximum Engine hp Emission Standards in (g/hp-hr) NOx CO VOC HC+NOx >25 hp and < 100 hp - 4.85 - 2.83 >100 hp 1.0 2.0 0.7 - [R307-510-4(1)] In Compliance. This well was drilled before 2016 and the pumpjack engine is subject to the performance standards in NSPS (60) JJJJ. See evaluation below. 40 Affected engines are certified or have an initial performance test per 40 CFR 60.4244. [R307-510-4(2)] In Compliance. Engines installed before 2016 are no longer under obligation to retain certifications or stack tests. 41 Affected engine exhaust vents are vertical and unrestricted. Stacks are 8' or greater if the site horsepower rating is 151 to 305 Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)] In Compliance. 42 Engine certifications or initial performance tests required are kept for the life of the engine at the source. [R307-510-5] In Compliance. A record of an initial performance test was not provided to the DAQ for inspection or not kept by UWO. Engines manufactured before 2008 or installed pre-2016 are not required to maintain a performance test results for life. 46 Visible Emissions 47 Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the following opacity limits: Installations constructed on or before 4/25/1971 40% Installations constructed after 4/25/1971 20% Gasoline engines 0% Diesel engines manufactured after 1/1/1973 20% Diesel engines manufactured before 1/1/1973 40% Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3] In Compliance. No visible emissions were detected. 55 Emission Inventory: 56 An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. The operator submitted for the 2020 emissions inventory. 57 NSPS (Part 60) OOOOa: Standards of Performance for Crude Oil and Natural Gas Facilities for which Construction, Modification or Reconstruction Commenced After September 18, 2015 [40 CFR 60 Subpart OOOOa] Not Applicable. The tank battery at this source no longer has the production to have the PTE in excess of 4 TPY and are no longer an affected facility under this subpart. There are no other affected facilities installed. 4 59 NSPS (Part 60) JJJJ: Standards of Performance for Stationary Spark Ignition Internal Combustion Engines [40 CFR 60 Subpart JJJJ] In Compliance. The engine at this source is not certified. Stack testing may or may not have been performed but, the record retention time limit for this testing has expired. The maintenance provisions are met to comply. PREVIOUS ENFORCEMENT ACTIONS: No enforcement actions within the past five years. COMPLIANCE STATUS & RECOMMENDATIONS: Out of Compliance - In consideration of the joint consent decree with the US EPA, still in negotiation with UWO, no further enforcement action is taken. RECOMMENDATION FOR NEXT INSPECTION: The DAQ has no recommendations for the next inspector other than what are customary. The DAQ recommends the inspection frequency of this source be reduced. ATTACHMENTS: Email