HomeMy WebLinkAboutDAQ-2024-0042571 DAQC-011-24 CAERS ID: 15489 (B4) MEMORANDUM TO: STACK TEST FILE – WESCO OPERATING INC. – Three Mile 12-2/12-7 Site THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Paul Bushman, Environmental Scientist DATE: January 4, 2024 SUBJECT: Source: Cummins G5.9L Engine; SN: 73542588 Contact: Dave Weinert: 307-577-5392 Location: San Juan County, Utah Test Contractor: Great Plains Analytical Services, Inc. Permit/AO#: Permit by Rule Action Code: TR Subject: Review of stack test report dated July 20, 2023 On December 29, 2023, Utah Division of Air Quality (DAQ) received a test report for the above listed unit at Three Mile 12-2/12-7 Site in San Juan County, Utah. Testing was performed December 19, 2023, to demonstrate compliance with the emission limits found in 40 CFR Part 60, Subpart JJJJ. The calculated test results are: Source Test Date Test Method Pollutant Tester Results DAQ Results Limits Cummins G5.9L SN: 73542588 December 19, 2023 ASTM D6348-3 NOx 1.961 g/hp- hr 1.919 g/hp-hr 2.83 g/hp-hr HC + NOx N/A 1.922 g/hp-hr 2.83 g/hp-hr CO 1.593 g/hp- hr 1.639 g/hp-hr 4.85 g/hp-hr DEVIATIONS: None. CONCLUSION: The stack test report appears to be acceptable. RECOMMENDATION: The emissions from the above units should be considered to have been in compliance with the emission limits of 40 CFR 60 subpart JJJJ during testing. ATTACHMENTS: DAQ stack test review excel spreadsheets, Wesco Operating Inc. stack test report. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43