HomeMy WebLinkAboutDAQ-2024-0072571
DAQC-PBR153810001-24
Site ID 15381 (B1)
MEMORANDUM
TO: FILE – SCOUT ENERGY MANAGEMENT, LLC – W Point 4-17-9-16
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Chris Jensen, Environmental Scientist
DATE: March 25, 2024
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: March 20, 2024
SOURCE LOCATION: W Point 4-17-9-16
Lat:40.03651 Long: -110.150009
Business Office:
13800 Montfort Drive, Suite 100
Dallas, TX 752404
SOURCE TYPE: Tank Battery
Duchesne County
API: 4301332280, 4301350699, 4301350701
SOURCE CONTACTS: Kevan Stevens, Local Air Quality Specialist
435-210-8355
Kevan.stevens@scoutep.com
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local
gas plant. The oil and process water in the storage tanks is
loaded into tanker trucks and hauled off-site for processing and
disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart JJJJ, 40 CFR 60 Subpart
OOOO.
SOURCE EVALUATION: Site Type: PBR- Uncontrolled
Voluntarily Controlled by Flare
Site powered by Engine
2
The source registered: 5000 Estimated Oil BBL.
DOGM current 12 month rolling production is: 5,150 BBLs.
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean Burn Make -
Arrow (Lufkin) Model - L-795 Mfg Year - 2011 Horse Power -
65 Combustion - Natural Gas, Pneumatic, Tank
Pneumatic Controllers
Continuous bleed natural gas-driven pneumatic controllers are in compliance with 40 CFR 60.5390 or
60.5390a as applicable. Exemptions to tagging and record keeping requirements apply to controllers
existing before 12/1/2015. [R307-502-4]
In Compliance. This source does not use continuous bleed natural gas-driven pneumatic
controllers.
Oil and Gas Industry Registration Requirement
The source is registered with the DAQ. [R307-505-3(3)]
In Compliance.
Registration has been updated within 30 days of a company name change, removal or addition of control
devices, or termination of operations. [R307-505-3(3)]
In Compliance.
Storage Vessels
Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. All hatches were found closed at the start of the evaluation.
Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. The DAQ did not identify any modifications or unauthorized equipment.
Records for each of the following are kept for three years:
Storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if required
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled per
R307-506-4(2).
[R307-506-5]
In Compliance. The recordkeeping procedures of the Operator, concerning these requirements,
are found to be orderly and complete. These records were reviewed at the local office.
3
Natural Gas Engines
Engines subject to R307-510 (does not have an AO, began operations, installed or modified after January
1, 2016) meet the following limits:
Maximum Engine hp Emission Standards in (g/hp-hr)
NOx CO VOC HC+NOx
>25 hp and < 100 hp - 4.85 - 2.83
>100 hp 1.0 2.0 0.7 -
[R307-510-4(1)]
In Compliance. This well was drilled before 2016 and the pumpjack engine is subject to the
performance standards in NSPS (60) JJJJ.
Affected engines are certified or have an initial performance test per 40 CFR 60.4244. [R307-510-4(2)]
In Compliance. Scout produced an initial performance testing certificate completed in 2014.
Affected engine exhaust vents are vertical and unrestricted.
Stacks are 8' or greater if the site horsepower rating is 151 to 305
Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)]
In Compliance.
Engine certifications or initial performance tests required are kept for the life of the engine at the source.
[R307-510-5]
In Compliance. Still on file.
Visible Emissions
Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3]
In Compliance. No visible emissions were detected.
4
Emission Inventory:
An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. The previous Operator submitted for the 2020 emissions inventory.
Applicable Federal Regulations:
NSPS (Part 60) JJJJ: Standards of Performance for Stationary Spark Ignition Internal Combustion
Engines.
In Compliance. The engines at this source have been performance tested and the emissions were
within the limits allowed in this subpart. The recordkeeping and maintenance provisions are also
met to maintain the certification.
NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution.
In Compliance. This source is permitted with the State of Utah with legal and enforceable limits.
A monitoring, repair, and record keeping program is in place that would satisfy the requirements
of 40 CFR (60) OOOO for a tank affected facility. There are no other affected facilities that are
installed.
PREVIOUS ENFORCEMENT
ACTIONS: No enforcement actions within the past five years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In Compliance - The source was surveyed by AVO, and with an
OGI camera, was found to be well-kept with no visible or
fugitive emissions.
Requested records were provided in a timely manner and
reviewed at the local field office.
RECOMMENDATION FOR
NEXT INSPECTION: The DAQ has no Recommendations for the next inspector other
than what are customary. The DAQ recommends the inspection
frequency of this source be reduced. The DAQ was joined by
Scout personnel during the site inspection.