Loading...
HomeMy WebLinkAboutDAQ-2024-0073671 DAQC-PBR153010002-23 Site ID 15301 (B1) MEMORANDUM TO: FILE – SCOUT ENERGY MANAGEMENT, LLC – Mon Bt 1-14-9-16 THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager FROM: Stephen Foulger, Environmental Scientist DATE: August 4, 2023 SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION INSPECTION DATE: June 29, 2023 SOURCE LOCATION: Mon Bt 1-14-9-16 Lat: 40.052839 Long: -110.073575 Business Office: 13800 Montfort Drive, Suite 100 Dallas, TX 75240 SOURCE TYPE: Tank Battery Duchesne County API: 4301330703, 4301350253, 4301350254 SOURCE CONTACTS: Abby Molyneaux, Corporate Environmental Contact Phone: (972) 325-1170, Email: abby.molyneaux@scoutep.com Chris Patterson, Local Contact Phone: 970 620-3459, Email: chris.patterson@scoutep.com OPERATING STATUS: Operating PROCESS DESCRIPTION: Production wastewater is being injected back into oil-bearing ground formation. APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and Gas Industry, and UAC R307-201: Emission Standards: General Emission Standards; and UAC R307-150: Emission Inventories, and 40 CFR 60 Subpart OOOO. SOURCE EVALUATION: Site Type: PBR-Uncontrolled Controlled by flare Site powered by Engine The source registered: 7,999 Estimated Oil BBL. DOGM current 12 month rolling production is: 1,756 Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls. 2 REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean Burn Make - Arrow Model - L-795 Mfg Year - 2011 Horse Power - 65 Combustion - Natural Gas, Pneumatic, Tank Oil and Gas Industry Registration Requirement The source is registered with the DAQ. [R307-505-3(3)] In Compliance. Search of DAQ records shows source is properly registered. Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. Search of DAQ records shows source is properly registered. Storage Vessels Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2). [R307-506-4(6)] In Compliance. Records for each of the following are kept for three years: Storage vessel vent system inspections (openings, thief hatches, pressure relief devices, bypasses, etc.), if required Monthly crude oil throughput Emission calculations, actuals and sampling data when used to justify an exemption to storage vessel rules Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled per R307-506-4(2) [R307-506-5] In Compliance. Emission Inventory: An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. Search of DAQ records shows emissions inventory properly reported. NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution [40 CFR 60 Subpart OOOO] In Compliance. PREVIOUS ENFORCEMENT ACTIONS: No enforcement actions within the past five years. COMPLIANCE STATUS & RECOMMENDATIONS: In regards to Mon Bt 1-14-9-16: In Compliance - This source has been converted into a water injection facility. Recommend to decrease inspection frequency. 3 RECOMMENDATION FOR NEXT INSPECTION: This source has been converted into a water injection facility. Recommend to decrease inspection frequency. ATTACHMENTS: