HomeMy WebLinkAboutDAQ-2024-0041671
DAQC-PBR151340001-23
Site ID 15134 (B1)
MEMORANDUM
TO: FILE – OVINTIV USA INC. – Tomlin 4-6-3-1WH
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Fred Goodrich, Environmental Scientist
DATE: October 30, 2023
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: September 28, 2023
SOURCE LOCATION: Tomlin 4-6-3-1WH
Lat: 40.25737 Long: -110.04372
Business Office:
370 17th Street, Suite 1700
Denver, CO 80202
SOURCE TYPE: Tank Battery
Duchesne County
API: 4301351861
SOURCE CONTACTS: Brad Rowser, Local Contact
Phone: 435-646-4870, Email: brad.rowser@ovintiv.com
Jeanette Liang, Corporate Environmental Contact
Phone: 303-248-6822, Email: jeanette.liang@ovintiv.com
OPERATING STATUS: Temporarily down
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local gas
plant. The oil and process water in the storage tanks is loaded
into tanker trucks and hauled off site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart OOOO.
, -
2
SOURCE EVALUATION: Site Type: PBR-Uncontrolled
Voluntarily controlled by flare
Site powered by line.
The source registered: 20,000 Estimated Oil BBL.
DOGM current 12 month rolling production is: 4,006 BBLs.
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Pneumatic, Tank
8 Pneumatic Controllers
9 Continuous bleed natural gas-driven pneumatic controllers are in compliance with 40 CFR 60.5390 or
60.5390a as applicable. Exemptions to tagging and record keeping requirements apply to controllers
existing before December 1, 2015. [R307-502-4]
In Compliance. This source does not use continuous bleed controllers as described in 40 CFR
60.5365(d)(1).
15 Oil and Gas Industry Registration Requirement
16 The source is registered with the DAQ. [R307-505-3(3)]
In Compliance.
17 Registration has been updated within 30 days of a company name change, removal or addition of
control devices, or termination of operations. [R307-505-3(3)]
In Compliance.
18 Storage Vessels
19 Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. All hatches were found closed at the start of the evaluation.
23 Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. The DAQ did not identify any modifications or unauthorized equipment.
24 Records for each of the following are kept for three years:
Storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if required
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled
per R307-506-4(2)[R307-506-5]
In Compliance. The recordkeeping procedures of the operator are found to be orderly and
complete. These records were reviewed at the local office.
3
38 Natural Gas Engines
39 Engines subject to R307-510 (does not have an AO, began operations, installed or modified after
January 1, 2016) meet the following limits:
Maximum Engine hp Emission Standards in (g/hp-hr)
NOx CO VOC HC+NOx
>25 hp and < 100 hp - 4.85 - 2.83
>100 hp 1.0 2.0 0.7 -
[R307-510-4(1)]
In Compliance. Well-site is electrified by local power supplier. No internal combustion engines
present.
46 Visible Emissions
47 Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3]
Out of Compliance. Visible emissions were detected from VOC Combustor. The Ovintiv field
team corrected immediately.
55 Emission Inventory:
56 An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. The operator submitted for the 2020 emissions inventory.
60 NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance.
PREVIOUS ENFORCEMENT
ACTIONS: No enforcement actions within the past five years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to: Tomlin 4-6-3-1WH:
Out of Compliance. Opacity was observed coming from the
Well-site Combustor. Upon further investigation with the
Ovintiv local regulatory team, it was determined that the
combustor was being overrun from liquids from a work-over rig
that was performing down hole repair work on the Tomlin
4-6-3-1. Ovintiv immediately corrected the situation and cleared
up combustor emissions. No further action was taken due to
voluntarily controlled.
4
RECOMMENDATION FOR
NEXT INSPECTION: The DAQ recommends frequency of inspections remain current
as scheduled with enhanced AVO observance.
ATTACHMENTS: None.