Loading...
HomeMy WebLinkAboutDDW-2024-008326Sanitary Survey - Deficiency Report PWS Number:UTAH08024 Deficiency Points:150 Survey Date:05/24/2024 Survey Name:GOBLIN VALLEY STATE PARK Surveyor:David Kruse Sanitary Survey Category: DS SDWIS Severity Code: Significant Deficiency Distribution | DS001 | UTAH08024 DISTRIBUTION SYSTEM 40. No unprotected connection between the distribution system and a source of contamination. (If there is an unprotected connection, describe the location in detail.) Rule: R309-550-5(11)R309-550-5(11) Notes:A 3way connection under a single vacuum breaker is in place at one of the spickets in the ranger residence. If two hoses are connected to a single spicket, each hose needs an individual vacuum breaker. Deficiency Points: 50 Days until points become effective on IPS: 120 SDWIS Deficiency Description: D009 WATER MAINS SUSCEPTIBLE TO NEARBY CONTAMINATION SOURCES Sanitary Survey Category: DS SDWIS Severity Code: Significant Deficiency Distribution | DS001 | UTAH08024 DISTRIBUTION SYSTEM 41B. For a valve in a chamber, open end of vent pipe is at least 12 inches above grade or one foot above distribution line in a chamber that does not flood. Rule: R309-550-6(6)(b)Rule states the open end of the air relief vent pipe from automatic valves shall be provided with a #14 mesh, non-corrodible screen and a downward elbow, and where possible, be extended to at least one foot above grade. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Air release valve in the campground contained in buried chamber (not likely subject to flooding) less than 12 inches above the distribution line. Not downturned. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: D006 AIR RELIEF VALVE PIPE NOT DOWNTURNED Sanitary Survey Category: DS SDWIS Severity Code: Significant Deficiency Distribution | DS001 | UTAH08024 DISTRIBUTION SYSTEM 41D. Open end of vent line down-turned. Rule: R309-550-6(6)(b)Rule states the open end of the air relief vent pipe from automatic valves shall be provided with a #14 mesh, non-corrodible screen and a downward elbow, and where possible, be extended to at least one foot above grade. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Air release valve in the campground contained in buried chamber (not likely subject to flooding) less than 12 inches above the distribution line. Not downturned. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: D006 AIR RELIEF VALVE PIPE NOT DOWNTURNED Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST002 | STORAGE FACILITY ST002 93C. Access opening lid properly gasketed Rule: R309-545-14(2)Rule requires the access opening to a tank to be furnished with a gasket between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Gasket needs replacing on both lids. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST002 | STORAGE FACILITY ST002 99B. Overflow line covered with #4 mesh non-corrodible screen Rule: R309-545-13(3)Rule requires overflow pipes to be screened with #4 mesh non-corrodible screens installed at a location least susceptible to damage by vandalism. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Screen needs replacing on the northern overflow line. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V012 END OF STORAGE TANK OVERFLOW PIPE LACKS NO. 4 SCREEN