HomeMy WebLinkAboutDAQ-2024-007188
1
DAQC-PBR146350001-23
Site ID 14635 (B1)
MEMORANDUM
TO: FILE – UINTA WAX OPERATING, LLC – Deep Creek 7-27-4-2E
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager
FROM: Stephen Foulger, Environmental Scientist
DATE: August 25, 2023
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: July 19, 2023
SOURCE LOCATION: Deep Creek 7-27-4-2E
Lat:40.10913 Long: -109.7517
Business Office:
5128 Apache Plume Road, Suite 300
Fort Worth, TX 76109
SOURCE TYPE: Tank Battery
Uintah County
API: 4304754258
SOURCE CONTACTS: Kaylene Bridwell, Corporate Environmental Contact
Phone: (405) 496-7308, Email: Kaylene.bridwell@uintawax.com
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local
gas plant. The oil and process water in the storage tanks is
loaded into tanker trucks and hauled off site for processing and
disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart OOOO.
SOURCE EVALUATION: Site Type: PBR- Controlled
Controlled by flare
Site powered by Engine
The source registered: 95000 Estimated Oil BBL.
2
DOGM current 12 month rolling production is: 2911.
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Engine – No info Provided, Pneumatic, Tank
Oil and Gas Industry Registration Requirement
The source is registered with the DAQ. [R307-505-3(3)]
In Compliance. Search of DAQ records shows source is properly registered
Registration has been updated within 30 days of a company name change, removal or addition of control
devices, or termination of operations. [R307-505-3(3)]
In Compliance. Search of DAQ records shows source is properly registered
Storage Vessels
Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. Thief hatches found closed and latched at the time of inspection.
Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. Source was found unmodified at the time of inspection.
Records for each of the following are kept for three years:
Storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if required
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled per
R307-506-4(2)
[R307-506-5]
In Compliance. DAQ inspector has reviewed these documents and found them compliant.
Natural Gas Engines
Engines subject to R307-510 (does not have an AO, began operations, installed or modified after January
1, 2016) meet the following limits:
Maximum Engine hp Emission Standards in (g/hp-hr)
NOx CO VOC HC+NOx
>25 hp and < 100 hp - 4.85 - 2.83
>100 hp 1.0 2.0 0.7 -
[R307-510-4(1)]
In Compliance.
3
Affected engines are certified or have an initial performance test per 40 CFR 60.4244. [R307-510-4(2)]
Out of Compliance. Operator failed to produce these required documents.
Affected engine exhaust vents are vertical and unrestricted.
Stacks are 8' or greater if the site horsepower rating is 151 to 305
Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)]
In Compliance.
Engine certifications or initial performance tests required are kept for the life of the engine at the source.
[R307-510-5]
Out of Compliance. Operator failed to produce these required documents.
Visible Emissions
Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3]
In Compliance. No visible emission observed at the time of inspection.
Emission Inventory:
An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. DAQ records show emissions inventory has been submitted.
NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance.
PREVIOUS ENFORCEMENT
ACTIONS: Compliance advisory issued 01/31/2020 to previous owners
Crescent Point Energy.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to: Deep Creek 7-27-4-2E:
Out of Compliance - This source was found non-compliant and
is voluntarily controlled. Recommend to keep the inspection
frequency the same due to decreased production and voluntary
control. No issues were found on-site; non-compliance status is
due to missing records.
RECOMMENDATION FOR
NEXT INSPECTION: Memo: Recommend to keep the inspection frequency the same
due to decreased production and voluntary control. No issues
were found on-site; non-compliance status is due to missing
records.