Loading...
HomeMy WebLinkAboutDAQ-2024-0073681 DAQC-PBR146120002-23 Site ID 14612 (B1) MEMORANDUM TO: FILE – UINTA WAX OPERATING, LLC – Deep Creek 11-32-3-2E THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager FROM: Stephen Foulger, Environmental Scientist DATE: June 6, 2023 SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION INSPECTION DATE: April 28, 2023 SOURCE LOCATION: Deep Creek 11-32-3-2E Lat: 40.176763 Long: -109.79547 Business Office: 5128 Apache Plume Road, Suite 300 Fort Worth, TX 76109 SOURCE TYPE: Tank Battery Uintah County API: 4304751664 SOURCE CONTACTS: Jennifer McQueen, Corporate Environmental Contact Phone: (303) 308-6285 Email: 720-705-8042 OPERATING STATUS: Operating PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products go through a separator where the oil and any water products are sent to storage tanks and the gas is used to power equipment on site (pump jack engine, tank heater, separator, flare, combustor, etc.) Any remaining gas is sent to a pipeline that feeds a local gas plant. The oil and process water in the storage tanks is loaded into tanker trucks and hauled off-site for processing and disposal. APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and Gas Industry, and UAC R307-201: Emission Standards: General Emission Standards; and UAC R307-150: Emission Inventories, and 40 CFR 60 Subpart OOOO. SOURCE EVALUATION: Site Type: PBR-Uncontrolled Controlled by flare Site powered by Engine The source registered: 5,000 Estimated Oil BBL. 2 DOGM current 12 month rolling production is: 1,669 Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls. REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean burn Make - Arrow Model - L-795 Mfg Year - 2012 Horse Power - 65 Combustion - Natural Gas, Pneumatic, Tank Oil and Gas Industry Registration Requirement The source is registered with the DAQ. [R307-505-3(3)] In Compliance: Search of DAQ records shows the source is registered properly. Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. Storage Vessels Thief hatches are kept closed and latched. [R307-506-4(1)] In Compliance: All thief hatches were found closed and latched at the time of inspection. Records for each of the following are kept for three years: Storage vessel vent system inspections (openings, thief hatches, pressure relief devices, bypasses, etc.), if required Monthly crude oil throughput Emission calculations, actuals and sampling data when used to justify an exemption to storage vessel rules Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled per R307-506-4(2) [R307-506-5] Not Observed. Partial compliance evaluation conducted and no records were observed at this time. Natural Gas Engines Engines subject to R307-510 (does not have an AO, began operations, installed or modified after January 1, 2016) meet the following limits: Maximum Engine hp Emission Standards in (g/hp-hr) NOx CO VOC HC+NOx >25 hp and < 100 hp - 4.85 - 2.83 >100 hp 1.0 2.0 0.7 - [R307-510-4(1)] In Compliance. Affected engines are certified or have an initial performance test per 40 CFR 60.4244. [R307-510-4(2)] Not Observed. Partial compliance evaluation conducted and no records were observed at this time. 3 Affected engine exhaust vents are vertical and unrestricted. Stacks are 8' or greater if the site horsepower rating is 151 to 305 Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)] In Compliance. Engine certifications or initial performance tests required are kept for the life of the engine at the source. [R307-510-5] Not Observed. Partial compliance evaluation conducted and no records were observed at this time. Visible Emissions Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the following opacity limits: Installations constructed on or before 4/25/1971 40% Installations constructed after 4/25/1971 20% Gasoline engines 0% Diesel engines manufactured after 1/1/1973 20% Diesel engines manufactured before 1/1/1973 40% Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3] In Compliance: No visible emissions were observed at the time of inspection. Emission Inventory: An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance: Search of DAQ records shows submission of emissions inventory. NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution [40 CFR 60 Subpart OOOO] In Compliance. PREVIOUS ENFORCEMENT ACTIONS: Compliance advisory issued on June 5, 2019, to previous owner Crescent Point Energy. COMPLIANCE STATUS & RECOMMENDATIONS: In regards to Deep Creek 11-32-3-2E: In Compliance - Found in compliance at the time of inspection. Recommend to decrease the frequency of inspections. RECOMMENDATION FOR NEXT INSPECTION: Decreased less frequent. The source found compliant at the time of inspection and production has dropped below 8,000 bbls annually. ATTACHMENTS: