HomeMy WebLinkAboutDAQ-2024-0073681
DAQC-PBR146120002-23
Site ID 14612 (B1) MEMORANDUM
TO: FILE – UINTA WAX OPERATING, LLC – Deep Creek 11-32-3-2E
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager
FROM: Stephen Foulger, Environmental Scientist
DATE: June 6, 2023
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: April 28, 2023
SOURCE LOCATION: Deep Creek 11-32-3-2E
Lat: 40.176763 Long: -109.79547
Business Office:
5128 Apache Plume Road, Suite 300
Fort Worth, TX 76109
SOURCE TYPE: Tank Battery
Uintah County
API: 4304751664
SOURCE CONTACTS: Jennifer McQueen, Corporate Environmental Contact
Phone: (303) 308-6285
Email: 720-705-8042
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local gas
plant. The oil and process water in the storage tanks is loaded
into tanker trucks and hauled off-site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart OOOO.
SOURCE EVALUATION: Site Type: PBR-Uncontrolled
Controlled by flare
Site powered by Engine
The source registered: 5,000 Estimated Oil BBL.
2
DOGM current 12 month rolling production is: 1,669
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean burn Make - Arrow
Model - L-795 Mfg Year - 2012 Horse Power - 65 Combustion -
Natural Gas, Pneumatic, Tank
Oil and Gas Industry Registration Requirement
The source is registered with the DAQ. [R307-505-3(3)]
In Compliance: Search of DAQ records shows the source is registered properly.
Registration has been updated within 30 days of a company name change, removal or addition of control
devices, or termination of operations. [R307-505-3(3)]
In Compliance.
Storage Vessels
Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance: All thief hatches were found closed and latched at the time of inspection.
Records for each of the following are kept for three years:
Storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if required
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled per
R307-506-4(2)
[R307-506-5]
Not Observed. Partial compliance evaluation conducted and no records were observed at this time.
Natural Gas Engines
Engines subject to R307-510 (does not have an AO, began operations, installed or modified after January
1, 2016) meet the following limits:
Maximum Engine hp Emission Standards in (g/hp-hr)
NOx CO VOC HC+NOx
>25 hp and < 100 hp - 4.85 - 2.83
>100 hp 1.0 2.0 0.7 -
[R307-510-4(1)]
In Compliance.
Affected engines are certified or have an initial performance test per 40 CFR 60.4244. [R307-510-4(2)]
Not Observed. Partial compliance evaluation conducted and no records were observed at this time.
3
Affected engine exhaust vents are vertical and unrestricted.
Stacks are 8' or greater if the site horsepower rating is 151 to 305
Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)]
In Compliance.
Engine certifications or initial performance tests required are kept for the life of the engine at the source.
[R307-510-5]
Not Observed. Partial compliance evaluation conducted and no records were observed at this time.
Visible Emissions
Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3]
In Compliance: No visible emissions were observed at the time of inspection.
Emission Inventory:
An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance: Search of DAQ records shows submission of emissions inventory.
NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance.
PREVIOUS ENFORCEMENT
ACTIONS: Compliance advisory issued on June 5, 2019, to previous owner
Crescent Point Energy.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to Deep Creek 11-32-3-2E:
In Compliance - Found in compliance at the time of inspection.
Recommend to decrease the frequency of inspections.
RECOMMENDATION FOR
NEXT INSPECTION: Decreased less frequent. The source found compliant at the time
of inspection and production has dropped below 8,000 bbls
annually.
ATTACHMENTS: