Loading...
HomeMy WebLinkAboutDAQ-2024-0074501 DAQC-338-24 Site ID 14575 (B4) MEMORANDUM TO: STACK TEST FILE – UINTA WAX OPERATING, LLC – ULT 13-26-3-1E THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Paul Bushman, Environmental Scientist DATE: April 15, 2024 SUBJECT: Source: One (1) Vortec 5.7L 142 hp engine SN: 57L0005919M17 Location: Remote location in Uintah County, UT Contact: Kaylene Bridwell: 405-496-7308 Tester: Oasis Emission Consultants, Inc. Site ID #: 14575 Permit/AO #: PBR Subject: Review of Pretest Protocol dated April 12, 2024 On April 12, 2024, Utah Division of Air Quality (DAQ) received a test notification for the testing of the above listed unit located at ULT 13-26-3-1E, Uintah County, UT. Testing will be performed May 13, 2024, to determine compliance with the emission limits found in Utah Administrative Code R307-510-4. PROTOCOL CONDITIONS: 1. RM 1 used to determine sample velocity traverses: OK 2. RM 3A used to determine dry molecular weight of the gas stream: OK 3. RM 4 used to determine moisture content of the gas stream: OK 4. RM 7E used to determine NOx emissions: OK 5. RM 10 used to determine CO emissions: OK 6. RM 18 used to determine gaseous organic compound emissions by GC: OK 7. RM 19 used to determine exhaust effluent flows and mass emission rates: OK 8. RM 25A used to determine VOC emissions: OK DEVIATIONS: No deviations stated in the protocol. CONCLUSION: The protocol appears to be acceptable. RECOMMENDATION: Send protocol review and test date confirmation notice. ATTACHMENTS: Uinta Wax Operating, LLC test notification and pretest protocol. 3 4 5 6 7 8 9